These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

126 related articles for article (PubMed ID: 10658554)

  • 1. Effect of spirometer temperature on FEV1 in a longitudinal epidemiological study.
    Gilliland FD; Linn W; Rappaport E; Avol E; Gong H; Peters J
    Occup Environ Med; 1999 Oct; 56(10):718-20. PubMed ID: 10658554
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Temperature corrections in routine spirometry.
    Cramer D; Peacock A; Denison D
    Thorax; 1984 Oct; 39(10):771-4. PubMed ID: 6495245
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Volume spirometers need automated internal temperature sensors.
    Johnson LR; Enright PL; Voelker HT; Tashkin DP
    Am J Respir Crit Care Med; 1994 Dec; 150(6 Pt 1):1575-80. PubMed ID: 7952617
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Dynamic BTPS correction factors for spirometric data.
    Hankinson JL; Viola JO
    J Appl Physiol Respir Environ Exerc Physiol; 1983 Oct; 55(4):1354-60. PubMed ID: 6629969
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Effects of temperature on Vitalograph spirometer readings.
    Perks WH; Sopwith T; Brown D; Jones CH; Green M
    Thorax; 1983 Aug; 38(8):592-4. PubMed ID: 6612650
    [TBL] [Abstract][Full Text] [Related]  

  • 6. BTPS correction with dynamic spirometers.
    Forche G; Harnoncourt K; Stadlober E; Zenker G
    Respiration; 1986; 49(4):274-9. PubMed ID: 3715213
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Effect of spirometer temperature on measurement of FEV1 shift changes.
    Hankinson JL; Castellan RM; Kinsley KB; Keimig DG
    J Occup Med; 1986 Dec; 28(12):1222-5. PubMed ID: 3806261
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Accuracy and repeatability of a pocket turbine spirometer: comparison with a rolling seal flow-volume spirometer.
    Malmberg LP; Hedman J; Sovijärvi AR
    Clin Physiol; 1993 Jan; 13(1):89-98. PubMed ID: 8435980
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Office spirometry: temperature conversion of volumes measured by the Vitalograph-R bellows spirometer is not necessary.
    Madsen F; Frølund L; Ulrik CS; Dirksen A
    Respir Med; 1999 Oct; 93(10):685-8. PubMed ID: 10581656
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Longitudinal validity of spirometers--a challenge in longitudinal studies.
    Künzli N; Kuna-Dibbert B; Keidel D; Keller R; Brändli O; Schindler C; Schweinzer KM; Leuenberger P; Ackermann-Liebrich U;
    Swiss Med Wkly; 2005 Aug; 135(33-34):503-8. PubMed ID: 16208589
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The Short-Term Effect of Breathing Tasks Via an Incentive Spirometer on Lung Function Compared With Autogenic Drainage in Subjects With Cystic Fibrosis.
    Sokol G; Vilozni D; Hakimi R; Lavie M; Sarouk I; Bat-El Bar ; Dagan A; Ofek M; Efrati O
    Respir Care; 2015 Dec; 60(12):1819-25. PubMed ID: 26374905
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Evaluation of a new electronic spirometer: the vitalograph "Escort" spirometer.
    Wiltshire N; Kendrick AH
    Thorax; 1994 Feb; 49(2):175-8. PubMed ID: 8128409
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A simple office spirometer for the pediatrician.
    Goddard RF; Klein WM; Smith RM
    Ann Allergy; 1980 Apr; 44(4):206-11. PubMed ID: 7369554
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Hand-held turbine spirometer: agreement with the conventional spirometer at baseline and after exercise.
    Korhonen H; Remes ST; Kannisto S; Korppi M
    Pediatr Allergy Immunol; 2005 May; 16(3):254-7. PubMed ID: 15853956
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Considerations in the use of different spirometers in epidemiological studies.
    Milanzi EB; Koppelman GH; Oldenwening M; Augustijn S; Aalders-de Ruijter B; Farenhorst M; Vonk JM; Tewis M; Brunekreef B; Gehring U
    Environ Health; 2019 Apr; 18(1):39. PubMed ID: 31023382
    [TBL] [Abstract][Full Text] [Related]  

  • 16. BTPS correction for ceramic flow sensor.
    Hankinson JL; Viola JO; Petsonk EL; Ebeling TR
    Chest; 1994 May; 105(5):1481-6. PubMed ID: 8181341
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Assessment of lung function on healthy children using an electronic spirometer and an air-flowmeter before and after inhalation of an adrenergic receptor stimulant.
    Dalén G; Kjellman B
    Acta Paediatr Scand; 1979 Jan; 68(1):103-8. PubMed ID: 153081
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Performance of Vitalograph wedge-bellows spirometer--comparison with a rolling seal spirometer.
    Kendrick AH; Laszlo G
    Clin Phys Physiol Meas; 1991 Feb; 12(1):65-73. PubMed ID: 2036774
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A comparison of the Jones and Stead-Wells spirometers.
    Glindmeyer HW; Anderson ST; Diem JE; Weill H
    Chest; 1978 May; 73(5):596-62. PubMed ID: 648210
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of lung volume in Greek swimmers, land based athletes, and sedentary controls using allometric scaling.
    Doherty M; Dimitriou L
    Br J Sports Med; 1997 Dec; 31(4):337-41. PubMed ID: 9429014
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.