BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

140 related articles for article (PubMed ID: 10659747)

  • 1. Size and positioning reproducibility of an 192Ir brachytherapy stepping source.
    Berndt A; Rickey DW; Rathee S; Bews J
    Med Phys; 2000 Jan; 27(1):129-31. PubMed ID: 10659747
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Monte Carlo calculation of dose rate distributions around 192Ir wires.
    Ballester F; Hernández C; Pérez-Calatayud J; Lliso F
    Med Phys; 1997 Aug; 24(8):1221-8. PubMed ID: 9284243
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The half-life of high dose rate Ir-192 sources.
    Podgorsak MB; DeWerd LA; Paliwal BR
    Med Phys; 1993; 20(4):1257-9. PubMed ID: 8413038
    [No Abstract]   [Full Text] [Related]  

  • 4. Anisotropy functions for 103Pd, 125I, and 192Ir interstitial brachytherapy sources.
    Nath R; Meigooni AS; Muench P; Melillo A
    Med Phys; 1993; 20(5):1465-73. PubMed ID: 8289730
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Absorbed dose determination at short distance from 60Co and 192Ir brachytherapy sources.
    Tölli H; Johansson KA
    Phys Med Biol; 1998 Nov; 43(11):3183-94. PubMed ID: 9832010
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Beta versus gamma dosimetry close to Ir-192 brachytherapy sources.
    Baltas D; Karaiskos P; Papagiannis P; Sakelliou L; Loeffler E; Zamboglou N
    Med Phys; 2001 Sep; 28(9):1875-82. PubMed ID: 11585218
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A Monte Carlo investigation of the dosimetric characteristics of the VariSource 192Ir high dose rate brachytherapy source.
    Karaiskos P; Angelopoulos A; Baras P; Sakelliou L; Sandilos P; Dardoufas K; Vlachos L
    Med Phys; 1999 Aug; 26(8):1498-502. PubMed ID: 10501049
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Dosimetry of 192Ir wires for LDR interstitial brachytherapy following the AAPM TG-43 dosimetric formalism.
    Karaiskos P; Papagiannis P; Angelopoulos A; Sakelliou L; Baltas D; Sandilos P; Vlachos L
    Med Phys; 2001 Feb; 28(2):156-66. PubMed ID: 11243338
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A dosimetric comparison of 169Yb versus 192Ir for HDR prostate brachytherapy.
    Lymperopoulou G; Papagiannis P; Sakelliou L; Milickovic N; Giannouli S; Baltas D
    Med Phys; 2005 Dec; 32(12):3832-42. PubMed ID: 16475783
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Absolute depth-dose-rate measurements for an 192Ir HDR brachytherapy source in water using MOSFET detectors.
    Zilio VO; Joneja OP; Popowski Y; Rosenfeld A; Chawla R
    Med Phys; 2006 Jun; 33(6):1532-9. PubMed ID: 16872060
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Characterization of a fiber-coupled Al2O3:C luminescence dosimetry system for online in vivo dose verification during 192Ir brachytherapy.
    Andersen CE; Nielsen SK; Greilich S; Helt-Hansen J; Lindegaard JC; Tanderup K
    Med Phys; 2009 Mar; 36(3):708-18. PubMed ID: 19378731
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Implantation guidelines for 169 Yb seed interstitial treatments.
    Piermattei A; Azario L; Montemaggi P
    Phys Med Biol; 1995 Aug; 40(8):1331-8. PubMed ID: 7480116
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of calculated and measured heterogeneity correction factors for 125I, 137Cs, and 192Ir brachytherapy sources near localized heterogeneities.
    Williamson JF; Perera H; Li Z; Lutz WR
    Med Phys; 1993; 20(1):209-22. PubMed ID: 8455503
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Dosimetric characteristics of a new high-intensity 192Ir source for remote afterloading.
    Meigooni AS; Kleiman MT; Johnson JL; Mazloomdoost D; Ibbott GS
    Med Phys; 1997 Dec; 24(12):2008-13. PubMed ID: 9434984
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Assessment of the relative dose distribution around an 192Ir line source using a liquid ionization chamber.
    Bahar-Gogani J; Wickman G; Johansson L; Johansson BE
    Med Phys; 1999 Sep; 26(9):1932-42. PubMed ID: 10505883
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Quantitative verification of 192Ir PDR and HDR source structure by pin-hole autoradiography.
    Kirov AS; Meigooni AS; Zhu Y; Valicenti RK; Williamson JF
    Med Phys; 1995 Nov; 22(11 Pt 1):1753-7. PubMed ID: 8587529
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Application of the Monte Carlo integration (MCI) method for calculation of the anisotropy of 192Ir brachytherapy sources.
    Baltas D; Giannouli S; Garbi A; Diakonos F; Geramani K; Ioannidis GT; Tsalpatouros A; Uzunoglu N; Kolotas C; Zamboglou N
    Phys Med Biol; 1998 Jun; 43(6):1783-801. PubMed ID: 9651040
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Accuracy assessment of the superposition principle for evaluating dose distributions of elongated and curved 103Pd and 192Ir brachytherapy sources.
    Bannon EA; Yang Y; Rivard MJ
    Med Phys; 2011 Jun; 38(6):2957-63. PubMed ID: 21815369
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Measurement and calculation of heterogeneity correction factors for an Ir-192 high dose-rate brachytherapy source behind tungsten alloy and steel shields.
    Kirov AS; Williamson JF; Meigooni AS; Zhu Y
    Med Phys; 1996 Jun; 23(6):911-9. PubMed ID: 8798161
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Verification of computerized treatment planning for HDR 192Ir brachytherapy for gynaecological cancer.
    Buzdar SA; Gadhi MA; Rao MA; Laghari NA; Anees M
    J Pak Med Assoc; 2009 Feb; 59(2):113-5. PubMed ID: 19260579
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.