These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

118 related articles for article (PubMed ID: 10664999)

  • 1. Estimating plasma volume from red cell volume.
    Cosgriff PS; Blunkett M; Morrish O
    Nucl Med Commun; 1999 Dec; 20(12):1165-7. PubMed ID: 10664999
    [TBL] [Abstract][Full Text] [Related]  

  • 2. SIMULTANEOUS RED CELL MASS AND PLASMA VOLUME DETERMINATIONS USING 51-CR TAGGED RED CELLS AND 125-I LABELED ALBUMIN.
    WOOD GA; LEVITT SH
    J Nucl Med; 1965 Jun; 6():433-40. PubMed ID: 14317650
    [No Abstract]   [Full Text] [Related]  

  • 3. 99mTc-albumin can replace 125I-albumin to determine plasma volume repeatedly.
    Bonfils PK; Damgaard M; Stokholm KH; Nielsen SL
    Scand J Clin Lab Invest; 2012 Oct; 72(6):447-51. PubMed ID: 22646079
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Studies with nonradioisotopic sodium chromate. II. Single- and double-label 52Cr/51Cr posttransfusion recovery estimations.
    Heaton WA; Keegan T; Hanbury CM; Holme S; Pleban P
    Transfusion; 1989 Oct; 29(8):703-7. PubMed ID: 2799896
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Measurement of plasma volume using 99Tc(m)-labelled DMP-HSA.
    du Raan H; Lötter MG; Harris GW; van Aswegen A; Otto AC; Nel MG; Badenhorst PN; Verbeke KA; Verbruggen AM
    Nucl Med Commun; 2000 Jun; 21(6):539-44. PubMed ID: 10894563
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Splenic red cell sequestration and blood volume measurements in conscious pigs.
    Hannon JP; Bossone CA; Rodkey WG
    Am J Physiol; 1985 Mar; 248(3 Pt 2):R293-301. PubMed ID: 3976907
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of isotope dilution technique and haematocrit determination for blood volume estimation in rats subjected to haemorrhage.
    Ware J; Norman M; Larsson M
    Res Exp Med (Berl); 1984; 184(2):125-30. PubMed ID: 6382491
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The ratio of body haematocrit to venous haematocrit in open heart surgery and estimation of the blood volume in the large and small vessels.
    Tanos B; Kovács G
    Acta Chir Acad Sci Hung; 1979; 20(2-3):141-8. PubMed ID: 555176
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Regional blood flow, microvascular blood content and tissue haematocrit in canine myocardium.
    Eliasen P; Amtorp O; Tøndevold E; Haunsø S
    Cardiovasc Res; 1982 Oct; 16(10):593-8. PubMed ID: 7151103
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The application of the gravimetric technic to the simultaneous determination of plasma volume using radioiodinated human serum albumin and red cell mass using sodium radiochromate.
    ZIPF RE; WEBBER JM; GROVE GR
    Am J Clin Pathol; 1956 May; 26(5):487-94. PubMed ID: 13326860
    [No Abstract]   [Full Text] [Related]  

  • 11. SIMULTANEOUS MEASUREMENTS OF PLASMA AND RED CELL VOLUMES AND THE F CELLS RATIO IN SHEEP.
    MENZIES RA; WHITLOCK JH; TAPPER DN
    Cornell Vet; 1965 Apr; 55():229-32. PubMed ID: 14317481
    [No Abstract]   [Full Text] [Related]  

  • 12. Measurement of red blood cell volume, plasma volume, and total blood volume in baboons.
    Valeri CR; Lindberg JR; Contreras TJ; Pivacek LE; Austin RM; Valeri DA; Gray A; Emerson CP
    Am J Vet Res; 1981 Jun; 42(6):1025-9. PubMed ID: 7283232
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Determining plasma volume, blood volume, and red cell mass with 125I. SAM-TR-68-46.
    Logsdon DF; Green JF
    Tech Rep SAM-TR; 1968 Aug; ():1-2. PubMed ID: 5305495
    [No Abstract]   [Full Text] [Related]  

  • 14. Splenic haematocrit and the splenic plasma pool.
    Zhang B; Lewis SM
    Br J Haematol; 1987 May; 66(1):97-102. PubMed ID: 3593658
    [TBL] [Abstract][Full Text] [Related]  

  • 15. (99m) Tc-labelled human serum albumin cannot replace (125) I-labelled human serum albumin to determine plasma volume in patients with liver disease.
    Henriksen UL; Henriksen JH; Bendtsen F; Møller S
    Clin Physiol Funct Imaging; 2013 May; 33(3):211-7. PubMed ID: 23522015
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Peripheral blood hematocrit in critically ill surgical patients: an imprecise surrogate of true red blood cell volume.
    Takanishi DM; Yu M; Lurie F; Biuk-Aghai E; Yamauchi H; Ho HC; Chapital AD
    Anesth Analg; 2008 Jun; 106(6):1808-12. PubMed ID: 18499614
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The estimation of red cell volume with 51Cr-labelled erythrocytes and plasma volume with radioiodinated human serum albumin.
    HART D; METZ J
    J Clin Pathol; 1962 Sep; 15(5):459-61. PubMed ID: 13953029
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Haematocrit is invalid for estimating red cell volume: a prospective study in male volunteers.
    Jacob M; Annaheim S; Boutellier U; Hinske C; Rehm M; Breymann C; Krafft A
    Blood Transfus; 2012 Oct; 10(4):471-9. PubMed ID: 22682340
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Changes in red cell mass, plasma volume and haematocrit in patients on continuous ambulatory peritoneal dialysis.
    de Paepe M; Lameire N; Schelstraete K; Ringoir S
    Proc Eur Dial Transplant Assoc; 1981; 18():286-9. PubMed ID: 7329973
    [No Abstract]   [Full Text] [Related]  

  • 20. A comparison of methods of determining the 100 percent survival of preserved red cells.
    Valeri CR; Pivacek LE; Ouellet R; Gray A
    Transfusion; 1984; 24(2):105-8. PubMed ID: 6710581
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.