These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

161 related articles for article (PubMed ID: 10667697)

  • 1. Postanalytical factors and their influence on analytical quality specifications.
    Goldschmidt HM
    Scand J Clin Lab Invest; 1999 Nov; 59(7):551-4. PubMed ID: 10667697
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Quality indicators and specifications for key processes in clinical laboratories: a preliminary experience.
    Kirchner MJ; Funes VA; Adzet CB; Clar MV; Escuer MI; Girona JM; Barellas RM; Alsina CP; Aguilá CR; Isern GT; Navarro CV
    Clin Chem Lab Med; 2007; 45(5):672-7. PubMed ID: 17484633
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Quality indicators and specifications for the extra-analytical phases in clinical laboratory management.
    Ricós C; García-Victoria M; de la Fuente B
    Clin Chem Lab Med; 2004; 42(6):578-82. PubMed ID: 15259371
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Effect of accreditation schemes on the setting of quality specifications by laboratories.
    Libeer JC
    Scand J Clin Lab Invest; 1999 Nov; 59(7):575-8. PubMed ID: 10667702
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Performance specifications for the extra-analytical phases of laboratory testing: Why and how.
    Plebani M;
    Clin Biochem; 2017 Jul; 50(10-11):550-554. PubMed ID: 28167246
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The NEXUS vision: an alternative to the reference value concept.
    Goldschmidt HM
    Clin Chem Lab Med; 2004; 42(7):868-73. PubMed ID: 15327025
    [TBL] [Abstract][Full Text] [Related]  

  • 7. European specialist porphyria laboratories: diagnostic strategies, analytical quality, clinical interpretation, and reporting as assessed by an external quality assurance program.
    Aarsand AK; Villanger JH; Støle E; Deybach JC; Marsden J; To-Figueras J; Badminton M; Elder GH; Sandberg S
    Clin Chem; 2011 Nov; 57(11):1514-23. PubMed ID: 21937752
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Quality specifications based on analysis of effects of performance on clinical decision-making.
    Petersen PH
    Scand J Clin Lab Invest; 1999 Nov; 59(7):517-21. PubMed ID: 10667690
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Quality Indicators for the Total Testing Process.
    Plebani M; Sciacovelli L; Aita A
    Clin Lab Med; 2017 Mar; 37(1):187-205. PubMed ID: 28153366
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A Retrospective Analysis of Corrected Laboratory Results in a Large Academic Medical Center.
    Kalt DA
    Am J Clin Pathol; 2019 Jul; 152(2):200-206. PubMed ID: 30985883
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [The incorrect laboratory result. Part 1: Pre- and postanalytical phase].
    Fiedler GM; Thiery J
    Internist (Berl); 2004 Mar; 45(3):315-29; quiz 330. PubMed ID: 15074319
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The evolving regulatory environment and bedside metabolic monitoring of the acute care patient.
    Baer DM; Belsey RE
    Chest; 1990 May; 97(5 Suppl):191S-197S. PubMed ID: 2183975
    [No Abstract]   [Full Text] [Related]  

  • 13. Pre- and postanalytical errors in haematology.
    De la Salle B
    Int J Lab Hematol; 2019 May; 41 Suppl 1():170-176. PubMed ID: 31069968
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Recognizing and Reducing Analytical Errors and Sources of Variation in Clinical Pathology Data in Safety Assessment Studies.
    Schultze AE; Irizarry AR
    Toxicol Pathol; 2017 Feb; 45(2):281-287. PubMed ID: 28178899
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Effect of current and forthcoming European legislation and standardization on the setting of quality specifications by laboratories.
    Haeckel R; Kindler M
    Scand J Clin Lab Invest; 1999 Nov; 59(7):569-73. PubMed ID: 10667701
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Quality specifications for reference methods.
    Thienpont LM
    Scand J Clin Lab Invest; 1999 Nov; 59(7):535-8. PubMed ID: 10667694
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Preanalytical quality improvement. In pursuit of harmony, on behalf of European Federation for Clinical Chemistry and Laboratory Medicine (EFLM) Working group for Preanalytical Phase (WG-PRE).
    Lippi G; Banfi G; Church S; Cornes M; De Carli G; Grankvist K; Kristensen GB; Ibarz M; Panteghini M; Plebani M; Nybo M; Smellie S; Zaninotto M; Simundic AM;
    Clin Chem Lab Med; 2015 Feb; 53(3):357-70. PubMed ID: 25490032
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Performance criteria and quality indicators for the pre-analytical phase.
    Plebani M; Sciacovelli L; Aita A; Pelloso M; Chiozza ML
    Clin Chem Lab Med; 2015 May; 53(6):943-8. PubMed ID: 25719322
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Sunway Medical Laboratory Quality Control Plans Based on Six Sigma, Risk Management and Uncertainty.
    Jairaman J; Sakiman Z; Li LS
    Clin Lab Med; 2017 Mar; 37(1):163-176. PubMed ID: 28153364
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Managing quality vs. measuring uncertainty in the medical laboratory.
    Westgard JO
    Clin Chem Lab Med; 2010; 48(1):31-40. PubMed ID: 19919330
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.