  • 1. [A test object for quality control of the instrument for doppler (duplex) ultrasonography, based on the Draft IEC 61685 Standard].
    Kollmann C; Bezemer RA; Fredfeldt KE; Schaarschmidt UG; Teirlinck CJ
    Ultraschall Med; 1999 Dec; 20(6):248-57. PubMed ID: 10670070
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Development of an example flow test object and comparison of five of these test objects, constructed in various laboratories.
    Teirlinck CJ; Bezemer RA; Kollmann C; Lubbers J; Hoskins PR; Ramnarine KV; Fish P; Fredeldt KE; Schaarschmidt UG
    Ultrasonics; 1998 Feb; 36(1-5):653-60. PubMed ID: 9651595
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [The Doppler Simulator DS 81. A new calibration method for ultrasound-cw-Doppler blood flow measurement devices].
    Reuter R; Trier HG
    Ultraschall Med; 1983 Sep; 4(3):188-91. PubMed ID: 6227994
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Objective performance testing and quality assurance of medical ultrasound equipment.
    Thijssen JM; Weijers G; de Korte CL
    Ultrasound Med Biol; 2007 Mar; 33(3):460-71. PubMed ID: 17275983
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Optical devices used for image analysis of pigmented skin lesions: a proposal for quality assurance protocol using tissue-like phantoms.
    Lualdi M; Colombo A; Carrara M; Scienza L; Tomatis S; Marchesini R
    Phys Med Biol; 2006 Dec; 51(23):N429-40. PubMed ID: 17110761
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Functional properties of diagnostic ultrasound instruments. A concept of trial building blocks for implementing quality assurance].
    Trier HG
    Ultraschall Med; 1994 Oct; 15(5):223-32. PubMed ID: 7801092
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Validation of a sensitivity performance index test protocol and evaluation of colour Doppler sensitivity for a range of ultrasound scanners.
    Browne JE; Watson AJ; Hoskins PR; Elliott AT
    Ultrasound Med Biol; 2004 Nov; 30(11):1475-83. PubMed ID: 15588958
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Intraoperative landmarking of vascular anatomy by integration of duplex and Doppler ultrasonography in image-guided surgery. Technical note.
    Sure U; Benes L; Bozinov O; Woydt M; Tirakotai W; Bertalanffy H
    Surg Neurol; 2005 Feb; 63(2):133-41; discussion 141-2. PubMed ID: 15680653
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The Eurocleft project 1996-2000: overview.
    Shaw WC; Semb G; Nelson P; Brattström V; Mølsted K; Prahl-Andersen B; Gundlach KK
    J Craniomaxillofac Surg; 2001 Jun; 29(3):131-40; discussion 141-2. PubMed ID: 11465251
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The current status of forensic science laboratory accreditation in Europe.
    Malkoc E; Neuteboom W
    Forensic Sci Int; 2007 Apr; 167(2-3):121-6. PubMed ID: 16876355
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Quality assurance in roentgen diagnosis. Comparison of constancy test methods according to DIN and IEC and practical consequences in Germany].
    Rassow J; Kütterer G; Neitzel U; Puschert W
    Aktuelle Radiol; 1996 Jul; 6(4):206-12. PubMed ID: 8924457
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A rotating cylinder phantom for flow and tissue color Doppler testing.
    Walker A; Henriksen E; Ringqvist I; Ask P
    Ultrasound Med Biol; 2009 Nov; 35(11):1892-8. PubMed ID: 19713031
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A review of Doppler ultrasound quality assurance protocols and test devices.
    Browne JE
    Phys Med; 2014 Nov; 30(7):742-51. PubMed ID: 25212384
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Sensitivity of new color systems: "maximum entropy method" and angio-color. Comparative in vitro flow measurements].
    Sohn C; Weskott HP; Schiesser M
    Ultraschall Med; 1996 Jun; 17(3):138-42. PubMed ID: 8767651
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Laboratory accreditation and proficiency testing].
    Kuwa K
    Rinsho Byori; 2003 May; 51(5):449-55. PubMed ID: 12806918
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Diagnostic kits in parasitology: which controls?].
    Rossi P
    Parassitologia; 2004 Jun; 46(1-2):145-9. PubMed ID: 15305705
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Blood transfusion in Europe: basic principles for initial and continuous training in transfusion medicine: an approach to an European harmonisation.
    Mueller MM; Seifried E
    Transfus Clin Biol; 2006 Nov; 13(5):282-5; quiz 286-9. PubMed ID: 17196864
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Performance of the Colson MAM BP 3AA1-2 automatic blood pressure monitor according to the European Society of Hypertension validation protocol.
    Pereira T; Maldonado J
    Rev Port Cardiol; 2005 Nov; 24(11):1341-51. PubMed ID: 16463984
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A possible quality control protocol for Doppler ultrasound for organizational time optimization.
    Di Nallo AM; Strigari L; Benassi M
    J Exp Clin Cancer Res; 2006 Sep; 25(3):373-81. PubMed ID: 17167978
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Operationalization of food consumption surveys in Europe: recommendations from the European Food Consumption Survey Methods (EFCOSUM) Project.
    De Henauw S; Brants HA; Becker W; Kaic-Rak A; Ruprich J; Sekula W; Mensink GB; Koenig JS;
    Eur J Clin Nutr; 2002 May; 56 Suppl 2():S75-88. PubMed ID: 12082520
    [TBL] [Abstract][Full Text] [Related]  