These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

224 related articles for article (PubMed ID: 10672843)

  • 1. Ultrasound-guided biopsies of abdominal organs with an automatic biopsy system. A retrospective analysis of the quality of biopsies and of hemorrhagic complications.
    Riemann B; Menzel J; Schiemann U; Domschke W; Konturek JW
    Scand J Gastroenterol; 2000 Jan; 35(1):102-7. PubMed ID: 10672843
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Ultrasound-guided fine-needle biopsy with an automatic full-incision system: the initial experiences and comparison with a conventional biopsy gun].
    Pokieser P; Kain R; Helbich T; Gebauer A; Neuhold N; Walter R; Tscholakoff D; Mostbeck GH
    Rofo; 1994 Jan; 160(1):70-4. PubMed ID: 8305696
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Ultrasound-guided fine needle puncture of the abdominal organs: indications, results, risks].
    Gebel M; Horstkotte H; Köster C; Brunkhorst R; Brandt M; Atay Z
    Ultraschall Med; 1986 Oct; 7(5):198-202. PubMed ID: 3538412
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Comparison of safety and sensitivity in diagnosis of liver lesion between ultrasound-guided 16 gauges and 18 gauges core needle biopsy].
    Chen F; Wang B; Chen LZ
    Zhonghua Yi Xue Za Zhi; 2007 Mar; 87(12):823-5. PubMed ID: 17565865
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The role of ultrasonography and automatic-needle biopsy in outpatient percutaneous liver biopsy.
    Lindor KD; Bru C; Jorgensen RA; Rakela J; Bordas JM; Gross JB; Rodes J; McGill DB; Reading CC; James EM; Charboneau JW; Ludwig J; Batts KP; Zinsmeister AR
    Hepatology; 1996 May; 23(5):1079-83. PubMed ID: 8621137
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Ultrasound guided fine- and coarse-needle puncture of the abdominal and retroperitoneal space].
    Binder T; Swobodnik W; Wechsler JG; Löschinger K; Eckert E; Schoengen A; Heimpel H; Ditschuneit H
    Dtsch Med Wochenschr; 1987 Jan; 113(2):43-8. PubMed ID: 3322762
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Limited Post-observation Period in Pediatric Outpatient Ultrasound-Guided Liver Biopsies.
    Hayatghaibi S; Ashton D; Cleveland H; Kukreja K
    Cardiovasc Intervent Radiol; 2017 Dec; 40(12):1899-1903. PubMed ID: 28597063
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Clinical analysis and prevention of complications associated with ultrasound-guided percutaneous thick needle biopsy].
    Bai L; Yang T; Tang Y; Mao JN; Chen W; Zhang Y; Wang Y; Yang WW
    Nan Fang Yi Ke Da Xue Xue Bao; 2009 May; 29(5):1055-6, 1059. PubMed ID: 19460740
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Application of a single needle type for all image-guided biopsies: results of 100 consecutive core biopsies in various organs using a novel tri-axial, end-cut needle.
    Diederich S; Padge B; Vossas U; Hake R; Eidt S
    Cancer Imaging; 2006 Jun; 6(1):43-50. PubMed ID: 16766268
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A real-world study evaluating ultrasound-guided percutaneous non-targeted liver biopsy needle failures and pathology sample-quality assessment in both end-cut and side-notch needles.
    Zhong J; Allard R; Hewitson D; Weston M; Hulson O; Burbidge S; Lambie H; Kaye T; Wyatt JI; Albazaz R
    Br J Radiol; 2021 Sep; 94(1125):20210475. PubMed ID: 34289324
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Yield and complications in ultrasound-guided biopsy of abdominal lesions. Comparison of fine-needle aspiration biopsy and 1.2-mm needle core biopsy using an automated biopsy gun.
    Nyman RS; Cappelen-Smith J; Brismar J; von Sinner W; Kagevi I
    Acta Radiol; 1995 Sep; 36(5):485-90. PubMed ID: 7640092
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Bleeding Complications After Percutaneous Liver Biopsy: Do Subcapsular Lesions Pose a Higher Risk?
    Potretzke TA; Saling LJ; Middleton WD; Robinson KA
    AJR Am J Roentgenol; 2018 Jul; 211(1):204-210. PubMed ID: 29708780
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Ultrasound-guided biopsy in focal lesions of the liver. Report on an automated biopsy system].
    Soyer P; Debroucker F; Lacheheb D; Barge J; Levesque M
    J Radiol; 1993 Apr; 74(4):215-9. PubMed ID: 8505717
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Ultrasound-guided Liver Biopsies in Children: A Single-center Experience and Risk Factors for Minor Bleeding.
    Bilreiro C; Noruegas MJ; Gonçalves I; Moreira Â
    J Pediatr Gastroenterol Nutr; 2017 Aug; 65(2):137-140. PubMed ID: 28394846
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The role of percutaneous biopsy in detection of pancreatic transplant rejection.
    Lee BC; McGahan JP; Perez RV; Boone JM
    Clin Transplant; 2000 Oct; 14(5):493-8. PubMed ID: 11048995
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Effect of operator experience and frequency of procedure performance on complication rate after ultrasound-guided percutaneous liver biopsies.
    Westheim BH; Aagenæs I; Østensen AB; Sanengen T; Almaas R
    J Pediatr Gastroenterol Nutr; 2013 Nov; 57(5):638-43. PubMed ID: 24177785
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Initial experience with EUS-guided trucut needle biopsies of perigastric organs.
    Wiersema MJ; Levy MJ; Harewood GC; Vazquez-Sequeiros E; Jondal ML; Wiersema LM
    Gastrointest Endosc; 2002 Aug; 56(2):275-8. PubMed ID: 12145612
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Safety of percutaneous biopsy of hepatocellular carcinoma with an 18 gauge automated needle.
    Ch Yu S; Metreweli C; Lau WY; Leung WT; Liew CT; Leung NW
    Clin Radiol; 1997 Dec; 52(12):907-11. PubMed ID: 9413963
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Safety and yield of percutaneous renal biopsy using an automatic 16G needle in native kidneys].
    Fortuño Andrés JR; de Lamo Muñoz S; García Pérez E; Mateos Alvarez A
    Radiologia; 2010; 52(2):153-6. PubMed ID: 20097395
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Single-pass percutaneous liver biopsy for diffuse liver disease using an automated device: experience in 154 procedures.
    Rivera-Sanfeliz G; Kinney TB; Rose SC; Agha AK; Valji K; Miller FJ; Roberts AC
    Cardiovasc Intervent Radiol; 2005; 28(5):584-8. PubMed ID: 15959699
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.