These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
3. Identifying respiratory events and artifacts using oscillatory impedance measurement in aPAP therapy. Harms R; Graetz B; Schöller B Biomed Tech (Berl); 2002; 47 Suppl 1 Pt 1():313-4. PubMed ID: 12451850 [TBL] [Abstract][Full Text] [Related]
4. Evaluation of a simplified oscillation technique for assessing airway obstruction in sleep apnoea. Farré R; Rigau J; Montserrat JM; Ballester E; Navajas D Eur Respir J; 2001 Mar; 17(3):456-61. PubMed ID: 11405525 [TBL] [Abstract][Full Text] [Related]
5. Assessment of airflow obstruction during CPAP by means of forced oscillation in patients with sleep apnea. Navajas D; Farré R; Rotger M; Badia R; Puig-de-Morales M; Montserrat JM Am J Respir Crit Care Med; 1998 May; 157(5 Pt 1):1526-30. PubMed ID: 9603133 [TBL] [Abstract][Full Text] [Related]
6. A system to generate simultaneous forced oscillation and continuous positive airway pressure. Farré R; Rotger M; Montserrat JM; Navajas D Eur Respir J; 1997 Jun; 10(6):1349-53. PubMed ID: 9192942 [TBL] [Abstract][Full Text] [Related]
13. Assessment of upper airway mechanics during sleep. Farré R; Montserrat JM; Navajas D Respir Physiol Neurobiol; 2008 Nov; 163(1-3):74-81. PubMed ID: 18638576 [TBL] [Abstract][Full Text] [Related]
14. Inspiratory dynamic obstruction detected by forced oscillation during CPAP. A model study. Farré R; Peslin R; Rotger M; Navajas D Am J Respir Crit Care Med; 1997 Mar; 155(3):952-6. PubMed ID: 9117031 [TBL] [Abstract][Full Text] [Related]
15. The use of auto-titrating continuous positive airway pressure for treatment of adult obstructive sleep apnea. An American Academy of Sleep Medicine review. Berry RB; Parish JM; Hartse KM Sleep; 2002 Mar; 25(2):148-73. PubMed ID: 11902425 [TBL] [Abstract][Full Text] [Related]
16. [Oscillatory measurement of airway resistance with the custo vit in comparison with Oscillaire and whole body plethysmography]. Fichter J; Wilkens JH; Fabel H Pneumologie; 1989 Jul; 43(7):382-6. PubMed ID: 2780532 [TBL] [Abstract][Full Text] [Related]
17. Accuracy of residual apnea-hypopnea index obtained using the continuous positive airway pressure device: application of new version 2.0 scoring rules for respiratory events during sleep. Kim DE; Hwangbo Y; Bae JH; Yang KI Sleep Breath; 2015 Dec; 19(4):1335-41. PubMed ID: 26407962 [TBL] [Abstract][Full Text] [Related]
18. Inspiratory effort sensation to added resistive loading in patients with obstructive sleep apnea. Tun Y; Hida W; Okabe S; Kikuchi Y; Kurosawa H; Tabata M; Shirato K Chest; 2000 Nov; 118(5):1332-8. PubMed ID: 11083683 [TBL] [Abstract][Full Text] [Related]
19. Practice parameters for the use of auto-titrating continuous positive airway pressure devices for titrating pressures and treating adult patients with obstructive sleep apnea syndrome. An American Academy of Sleep Medicine report. Littner M; Hirshkowitz M; Davila D; Anderson WM; Kushida CA; Woodson BT; Johnson SF; Merrill SW; Sleep; 2002 Mar; 25(2):143-7. PubMed ID: 11902424 [TBL] [Abstract][Full Text] [Related]