  • 1. TLD measurements of the relative output factors for the Leksell Gamma Knife.
    Yu C; Luxton G; Apuzzo ML; Petrovich Z
    Stereotact Funct Neurosurg; 1999; 72 Suppl 1():150-8. PubMed ID: 10681703
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Determination of output factors for the Leksell gamma knife using ion chamber, thermoluminescence detectors and films.
    Bilge H; Osen Z; Senkesen O; Kucucuk H; Cakir A; Sengoz M
    J BUON; 2006; 11(2):223-7. PubMed ID: 17318975
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Precision dosimetry for narrow photon beams used in radiosurgery-determination of Gamma Knife output factors.
    Mack A; Scheib SG; Major J; Gianolini S; Pazmandi G; Feist H; Czempiel H; Kreiner HJ
    Med Phys; 2002 Sep; 29(9):2080-9. PubMed ID: 12349929
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Measurements of the relative output factors for CyberKnife collimators.
    Yu C; Jozsef G; Apuzzo ML; Petrovich Z
    Neurosurgery; 2004 Jan; 54(1):157-61; discussion 161-2. PubMed ID: 14683553
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A simple and effective method for validation and measurement of collimator output factors for Leksell Gamma Knife Perfexion.
    Ma L; Kjäll P; Novotny J; Nordström H; Johansson J; Verhey L
    Phys Med Biol; 2009 Jun; 54(12):3897-907. PubMed ID: 19491451
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Measurement of Gamma Knife helmet factors using MOSFETs.
    Kurjewicz L; Berndt A
    Med Phys; 2007 Mar; 34(3):1007-12. PubMed ID: 17441247
    [TBL] [Abstract][Full Text] [Related]  

  • 7. TLD dose measurement: a simplified accurate technique for the dose range from 0.5 cGy to 1000 cGy.
    Yu C; Luxton G
    Med Phys; 1999 Jun; 26(6):1010-6. PubMed ID: 10436903
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Dosimetry and mechanical accuracy of the first rotating gamma system installed in North America.
    Kubo HD; Araki F
    Med Phys; 2002 Nov; 29(11):2497-505. PubMed ID: 12462714
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Shuttle dose at the Vienna Leksell Gamma Knife.
    Ertl A; Zehetmayer M; Schöggl A; Kitz K; Koschuch R; Stadtmann H; Kindl P
    Phys Med Biol; 1998 Jun; 43(6):1567-78. PubMed ID: 9651026
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A tissue equivalent phantom for stereotactic radiosurgery localization and dose verification.
    Coffey CW; Sanders M; Cashon K; Miller R; Walsh J; Patel P
    Stereotact Funct Neurosurg; 1993; 61 Suppl 1():130-41. PubMed ID: 8115745
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Monte Carlo calculated output factors of a Leksell Gamma Knife unit.
    Cheung JY; Yu KN; Ho RT; Yu CP
    Phys Med Biol; 1999 Dec; 44(12):N247-9. PubMed ID: 10616156
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Calibration of the Gamma Knife Perfexion using TG-21 and the solid water Leksell dosimetry phantom.
    McDonald D; Yount C; Koch N; Ashenafi M; Peng J; Vanek K
    Med Phys; 2011 Mar; 38(3):1685-93. PubMed ID: 21520881
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Verification of source and collimator configuration for Gamma Knife Perfexion using panoramic imaging.
    Cho YB; van Prooijen M; Jaffray DA; Islam MK
    Med Phys; 2010 Mar; 37(3):1325-31. PubMed ID: 20384269
    [TBL] [Abstract][Full Text] [Related]  

  • 14. An efficient method of measuring the 4 mm helmet output factor for the Gamma knife.
    Ma L; Li XA; Yu CX
    Phys Med Biol; 2000 Mar; 45(3):729-33. PubMed ID: 10730967
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Dosimetric characteristics and quality control tests for the collimator sectors of the Leksell Gamma Knife(®) Perfexion(TM).
    Bhatnagar JP; Novotny J; Huq MS
    Med Phys; 2012 Jan; 39(1):231-6. PubMed ID: 22225292
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Measurements of Gamma-Knife helmet output factors using a radiophotoluminescent glass rod dosimeter and a diode detector].
    Araki F; Kubo HD; Yang C; Ikegami T; Ishidoya T
    Nihon Hoshasen Gijutsu Gakkai Zasshi; 2004 Jan; 60(1):67-8. PubMed ID: 15041907
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Determination of the 4 mm Gamma Knife helmet relative output factor using a variety of detectors.
    Tsai JS; Rivard MJ; Engler MJ; Mignano JE; Wazer DE; Shucart WA
    Med Phys; 2003 May; 30(5):986-92. PubMed ID: 12773008
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A film technique for the determination of output factors and end effect times for the Leksell Gamma Knife.
    Ekstrand KE; Bourland JD
    Phys Med Biol; 2001 Mar; 46(3):703-6. PubMed ID: 11277218
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Determination of Collimator Helmet Factors for Leksell Gamma Knife 4C Unit Using GAF Chromic EBT3 Film and ImageJ Software.
    Natesan P; Palaniappan SM; M M; Ganesh KM; Bhaskara Rao M
    Asian Pac J Cancer Prev; 2021 Dec; 22(12):4031-4035. PubMed ID: 34967585
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of thermoluminescent dosimeter calibration irradiated in gamma knife and
    Moafi M; Geraily G; Shirazi AR
    J Cancer Res Ther; 2019 Mar; 15(Supplement):S123-S126. PubMed ID: 30900633
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.