These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

290 related articles for article (PubMed ID: 10683217)

  • 1. Newer technologies for endoscope disinfection: electrolyzed acid water and disposable-component endoscope systems.
    Nelson D
    Gastrointest Endosc Clin N Am; 2000 Apr; 10(2):319-28. PubMed ID: 10683217
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Improvement of the automatic endoscopic reprocessor: self-cleaning disinfecting connectors between endoscope and reprocessor.
    Ishino Y; Ido K; Sugano K
    Endoscopy; 2003 Jun; 35(6):469-71. PubMed ID: 12783342
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Inconsistencies in endoscope-reprocessing and infection-control guidelines: the importance of endoscope drying.
    Muscarella LF
    Am J Gastroenterol; 2006 Sep; 101(9):2147-54. PubMed ID: 16968511
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Efficacy of electrolyzed acid water in reprocessing patient-used flexible upper endoscopes: Comparison with 2% alkaline glutaraldehyde.
    Lee JH; Rhee PL; Kim JH; Kim JJ; Paik SW; Rhee JC; Song JH; Yeom JS; Lee NY
    J Gastroenterol Hepatol; 2004 Aug; 19(8):897-903. PubMed ID: 15242493
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Endoscope washers--a protocol for their use.
    Marchetti MG; Salvatorelli G; Finzi G; Cugini P
    J Hosp Infect; 2000 Nov; 46(3):210-5. PubMed ID: 11073730
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [HYGEA (Hygiene in gastroenterology--endoscope reprocessing): Study on quality of reprocessing flexible endoscopes in hospitals and in the practice setting].
    Bader L; Blumenstock G; Birkner B; Leiss O; Heesemann J; Riemann JF; Selbmann HK
    Z Gastroenterol; 2002 Mar; 40(3):157-70. PubMed ID: 11901449
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Endoscope drying/storage cabinet: interest and efficacy.
    Pineau L; Villard E; Duc DL; Marchetti B
    J Hosp Infect; 2008 Jan; 68(1):59-65. PubMed ID: 18055064
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Reprocessing flexible gastrointestinal endoscopes after a period of disuse: is it necessary?
    Vergis AS; Thomson D; Pieroni P; Dhalla S
    Endoscopy; 2007 Aug; 39(8):737-9. PubMed ID: 17661250
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Automatic flexible endoscope reprocessors.
    Muscarella LF
    Gastrointest Endosc Clin N Am; 2000 Apr; 10(2):245-57. PubMed ID: 10683211
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Endoscope reprocessing and repair costs.
    Burdick JS; Hambrick D
    Gastrointest Endosc Clin N Am; 2004 Oct; 14(4):717-24, ix-x. PubMed ID: 15363776
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Automated washing with the Reliance Endoscope Processing System and its equivalence to optimal manual cleaning.
    Alfa MJ; Olson N; DeGagne P
    Am J Infect Control; 2006 Nov; 34(9):561-70. PubMed ID: 17097450
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Reprocessing in digestive endoscopy units in Lombardy: results of a regional survey.
    Spinzi G; Fasoli R; Centenaro R; Minoli G;
    Dig Liver Dis; 2008 Nov; 40(11):890-6. PubMed ID: 18400569
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Real-time monitoring in managing the decontamination of flexible gastrointestinal endoscopes.
    Obee PC; Griffith CJ; Cooper RA; Cooke RP; Bennion NE; Lewis M
    Am J Infect Control; 2005 May; 33(4):202-6. PubMed ID: 15877014
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The microbial flora of the gastrointestinal tract and the cleaning of flexible endoscopes.
    Chu NS; Favero M
    Gastrointest Endosc Clin N Am; 2000 Apr; 10(2):233-44. PubMed ID: 10683210
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Reprocessing endoscopes: United States perspective.
    Rutala WA; Weber DJ
    J Hosp Infect; 2004 Apr; 56 Suppl 2():S27-39. PubMed ID: 15110120
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Reconciliation of FDA and societal guidelines for endoscope reprocessing.
    Alvarado C
    Gastrointest Endosc Clin N Am; 2000 Apr; 10(2):275-81. PubMed ID: 10683214
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Standards of infection control in reprocessing of flexible gastrointestinal endoscopes.
    Society of Gastroenterology Nurses and Associates, Inc
    Gastroenterol Nurs; 2006; 29(2):142-8. PubMed ID: 16609310
    [No Abstract]   [Full Text] [Related]  

  • 18. Endoscope disinfection using acidic electrolytic water.
    Tsuji S; Kawano S; Oshita M; Ohmae A; Shinomura Y; Miyazaki Y; Hiraoka S; Matsuzawa Y; Kamada T; Hori M; Maeda T
    Endoscopy; 1999 Sep; 31(7):528-35. PubMed ID: 10533736
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Current GI endoscope disinfection and QA practices.
    Moses FM; Lee JS
    Dig Dis Sci; 2004; 49(11-12):1791-7. PubMed ID: 15628705
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Non-United States guidelines for endoscope reprocessing.
    Tandon RK; Ahuja V
    Gastrointest Endosc Clin N Am; 2000 Apr; 10(2):295-318. PubMed ID: 10683216
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 15.