These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

69 related articles for article (PubMed ID: 10688109)

  • 1. Fewer women than men have positive SPECT and PET cardiac findings among patients with no history of heart disease.
    Mullani NA; Caras D; Ahn C; Lundberg G; Page D; Kleinman D; Bladuell N; Weisman E; Patillo M; Posthauer J; Simone G
    J Nucl Med; 2000 Feb; 41(2):263-8. PubMed ID: 10688109
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Lower diagnostic accuracy of thallium-201 SPECT myocardial perfusion imaging in women: an effect of smaller chamber size.
    Hansen CL; Crabbe D; Rubin S
    J Am Coll Cardiol; 1996 Nov; 28(5):1214-9. PubMed ID: 8890818
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Gender-related imaging issues in assessment of coronary artery disease by nuclear techniques.
    Grover-McKay M
    Am J Card Imaging; 1996 Jan; 10(1):54-64. PubMed ID: 8680134
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Evaluation of myocardial ischemia using a rest metabolism/stress perfusion protocol with fluorine-18 deoxyglucose/technetium-99m MIBI and dual-isotope simultaneous-acquisition single-photon emission computed tomography.
    Sandler MP; Videlefsky S; Delbeke D; Patton JA; Meyerowitz C; Martin WH; Ohana I
    J Am Coll Cardiol; 1995 Oct; 26(4):870-8. PubMed ID: 7560611
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Diagnostic accuracy of technetium-99m-MIBI myocardial SPECT in women and men.
    Santana-Boado C; Candell-Riera J; Castell-Conesa J; Aguadé-Bruix S; García-Burillo A; Canela T; González JM; Cortadellas J; Ortega D; Soler-Soler J
    J Nucl Med; 1998 May; 39(5):751-5. PubMed ID: 9591568
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Sex differences in evaluation and outcome after stress testing.
    Roger VL; Jacobsen SJ; Weston SA; Pellikka PA; Miller TD; Bailey KR; Gersh BJ
    Mayo Clin Proc; 2002 Jul; 77(7):638-45. PubMed ID: 12108601
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Myocardial scintigraphy with Tc-99m-MIBI for assessing the extent and severity of coronary disease: a comparison with thallium-201 and equilibrium angiocardioscintigraphy].
    Leoncini M; Sciagrà R; Bisi G; Santoro GM; Fazzini PF
    G Ital Cardiol; 1993 Feb; 23(2):127-38. PubMed ID: 8491353
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Diagnosis of coronary artery disease in women: roles of three dimensional imaging with magnetic resonance or positron emission tomography.
    Patterson RE; Churchwell KB; Eisner RL
    Am J Card Imaging; 1996 Jan; 10(1):78-88. PubMed ID: 8680137
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Intravenous dipyridamole technetium-99m MMI myocardial perfusion scintigraphy for detection of coronary artery disease.
    Yang CC; Wu CC; Jong SB; Shen LH; Wey SP; Ting G
    Gaoxiong Yi Xue Ke Xue Za Zhi; 1992 Feb; 8(2):59-74. PubMed ID: 1404526
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Limited incremental diagnostic values of attenuation-noncorrected gating and ungated attenuation correction to rest/stress myocardial perfusion SPECT in patients with an intermediate likelihood of coronary artery disease.
    Lee DS; So Y; Cheon GJ; Kim KM; Lee MM; Chung JK; Lee MC
    J Nucl Med; 2000 May; 41(5):852-9; discussion 860-2. PubMed ID: 10809202
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A retrospective study of the diagnostic accuracy of a community hospital-based PET center for the detection of coronary artery disease using rubidium-82.
    Williams BR; Mullani NA; Jansen DE; Anderson BA
    J Nucl Med; 1994 Oct; 35(10):1586-92. PubMed ID: 7931654
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Identifying high-risk asymptomatic diabetic patients who are candidates for screening stress single-photon emission computed tomography imaging.
    Rajagopalan N; Miller TD; Hodge DO; Frye RL; Gibbons RJ
    J Am Coll Cardiol; 2005 Jan; 45(1):43-9. PubMed ID: 15629371
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A new algorithm for the quantitation of myocardial perfusion SPECT. II: validation and diagnostic yield.
    Sharir T; Germano G; Waechter PB; Kavanagh PB; Areeda JS; Gerlach J; Kang X; Lewin HC; Berman DS
    J Nucl Med; 2000 Apr; 41(4):720-7. PubMed ID: 10768575
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Gender-related differences in clinical management after exercise nuclear testing.
    Hachamovitch R; Berman DS; Kiat H; Bairey-Merz N; Cohen I; Cabico JA; Friedman JD; Germano G; Van Train KF; Diamond GA
    J Am Coll Cardiol; 1995 Nov; 26(6):1457-64. PubMed ID: 7594071
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Sequential dual-isotope SPECT imaging with thallium-201 and technetium-99m-sestamibi.
    Heo J; Wolmer I; Kegel J; Iskandrian AS
    J Nucl Med; 1994 Apr; 35(4):549-53. PubMed ID: 8151373
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evaluation of coronary artery disease using technetium-99m-sestamibi first-pass and perfusion imaging with dipyridamole infusion.
    Sciagrà R; Bisi G; Santoro GM; Briganti V; Leoncini M; Fazzini P
    J Nucl Med; 1994 Aug; 35(8):1254-64. PubMed ID: 8046476
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Indications for clinical applications of positron emission tomography in cardiology. Position report of the PET Cardiology Study Group of the German Society of Nuclear Medicine and the Nuclear Cardiology Study Circle of the German Society of Cardiology].
    Z Kardiol; 1996 Jul; 85(7):453-68. PubMed ID: 8928543
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A prospective comparison of rubidium-82 PET and thallium-201 SPECT myocardial perfusion imaging utilizing a single dipyridamole stress in the diagnosis of coronary artery disease.
    Go RT; Marwick TH; MacIntyre WJ; Saha GB; Neumann DR; Underwood DA; Simpfendorfer CC
    J Nucl Med; 1990 Dec; 31(12):1899-905. PubMed ID: 2266384
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison of sulfur hexafluoride microbubble (SonoVue)-enhanced myocardial contrast echocardiography with gated single-photon emission computed tomography for detection of significant coronary artery disease: a large European multicenter study.
    Senior R; Moreo A; Gaibazzi N; Agati L; Tiemann K; Shivalkar B; von Bardeleben S; Galiuto L; Lardoux H; Trocino G; Carrió I; Le Guludec D; Sambuceti G; Becher H; Colonna P; Ten Cate F; Bramucci E; Cohen A; Bezante G; Aggeli C; Kasprzak JD
    J Am Coll Cardiol; 2013 Oct; 62(15):1353-61. PubMed ID: 23770168
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Myocardial perfusion imaging with PET.
    Schwaiger M
    J Nucl Med; 1994 Apr; 35(4):693-8. PubMed ID: 8151396
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.