These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
104 related articles for article (PubMed ID: 10699515)
1. Cardiac output measurement with an esophageal doppler in critically ill Emergency Department patients. Rodriguez RM; Berumen KA J Emerg Med; 2000 Feb; 18(2):159-64. PubMed ID: 10699515 [TBL] [Abstract][Full Text] [Related]
2. A prospective study on esophageal Doppler hemodynamic assessment in the ED. Rodriguez RM; Lum-Lung M; Dixon K; Nothmann A Am J Emerg Med; 2006 Oct; 24(6):658-63. PubMed ID: 16984833 [TBL] [Abstract][Full Text] [Related]
3. Interrater reliability of cardiac output measurements by transcutaneous Doppler ultrasound: implications for noninvasive hemodynamic monitoring in the ED. Nguyen HB; Losey T; Rasmussen J; Oliver R; Guptill M; Wittlake WA; Corbett SW Am J Emerg Med; 2006 Nov; 24(7):828-35. PubMed ID: 17098106 [TBL] [Abstract][Full Text] [Related]
4. [Monitoring cardiac output: esophageal doppler vs thermodilution]. Leone D; Servillo G; De Robertis E; Rossano F; Tufano R Minerva Anestesiol; 1998; 64(7-8):351-6. PubMed ID: 9796245 [TBL] [Abstract][Full Text] [Related]
6. Transthoracic echocardiography: an accurate and precise method for estimating cardiac output in the critically ill patient. Mercado P; Maizel J; Beyls C; Titeca-Beauport D; Joris M; Kontar L; Riviere A; Bonef O; Soupison T; Tribouilloy C; de Cagny B; Slama M Crit Care; 2017 Jun; 21(1):136. PubMed ID: 28595621 [TBL] [Abstract][Full Text] [Related]
7. The use of impedance cardiography in predicting mortality in emergency department patients with severe sepsis and septic shock. Napoli AM; Machan JT; Corl K; Forcada A Acad Emerg Med; 2010 Apr; 17(4):452-5. PubMed ID: 20370786 [TBL] [Abstract][Full Text] [Related]
8. Prediction of poor outcome of intensive care unit patients admitted from the emergency department. Rodriguez RM; Wang NE; Pearl RG Crit Care Med; 1997 Nov; 25(11):1801-6. PubMed ID: 9366761 [TBL] [Abstract][Full Text] [Related]
9. Measuring cardiac index with a focused cardiac ultrasound examination in the ED. Dinh VA; Ko HS; Rao R; Bansal RC; Smith DD; Kim TE; Nguyen HB Am J Emerg Med; 2012 Nov; 30(9):1845-51. PubMed ID: 22795411 [TBL] [Abstract][Full Text] [Related]
10. The test characteristics of physician clinical gestalt for determining the presence and severity of anaemia in patients seen at the emergency department of a tertiary referral hospital in Tanzania. Sawe HR; Mfinanga JA; Mwafongo V; Reynolds TA; Runyon MS Emerg Med J; 2016 May; 33(5):338-44. PubMed ID: 26612857 [TBL] [Abstract][Full Text] [Related]
11. Who Am I to Decide Whether This Person Is to Die Today? Physicians' Life-or-Death Decisions for Elderly Critically Ill Patients at the Emergency Department-ICU Interface: A Qualitative Study. Fassier T; Valour E; Colin C; Danet F Ann Emerg Med; 2016 Jul; 68(1):28-39.e3. PubMed ID: 26619758 [TBL] [Abstract][Full Text] [Related]
12. Nurse-determined assessment of cardiac output. Comparing a non-invasive cardiac output device and pulmonary artery catheter: a prospective observational study. Corley A; Barnett AG; Mullany D; Fraser JF Int J Nurs Stud; 2009 Oct; 46(10):1291-7. PubMed ID: 19423107 [TBL] [Abstract][Full Text] [Related]
13. The validity of trans-esophageal Doppler ultrasonography as a measure of cardiac output in critically ill adults. Dark PM; Singer M Intensive Care Med; 2004 Nov; 30(11):2060-6. PubMed ID: 15368037 [TBL] [Abstract][Full Text] [Related]
14. Noninvasive assessment of cardiac output in critically ill patients by analysis of the finger blood pressure waveform. Hirschl MM; Binder M; Gwechenberger M; Herkner H; Bur A; Kittler H; Laggner AN Crit Care Med; 1997 Nov; 25(11):1909-14. PubMed ID: 9366778 [TBL] [Abstract][Full Text] [Related]
15. [Non-invasive determination of cardiac output by continuous wave Doppler in air rescue service]. Knobloch K; Hubrich V; Rohmann P; Lüpkemann M; Phillips R; Gerich T; Krettek C Anasthesiol Intensivmed Notfallmed Schmerzther; 2005 Dec; 40(12):750-5. PubMed ID: 16362876 [TBL] [Abstract][Full Text] [Related]
16. Emergency physicians can reliably assess emergency department patient cardiac output using the USCOM continuous wave Doppler cardiac output monitor. Dey I; Sprivulis P Emerg Med Australas; 2005 Jun; 17(3):193-9. PubMed ID: 15953218 [TBL] [Abstract][Full Text] [Related]
18. Bioreactance is not reliable for estimating cardiac output and the effects of passive leg raising in critically ill patients. Kupersztych-Hagege E; Teboul JL; Artigas A; Talbot A; Sabatier C; Richard C; Monnet X Br J Anaesth; 2013 Dec; 111(6):961-6. PubMed ID: 23985531 [TBL] [Abstract][Full Text] [Related]
19. A prospective evaluation of emergency department bedside ultrasonography for the detection of acute cholecystitis. Summers SM; Scruggs W; Menchine MD; Lahham S; Anderson C; Amr O; Lotfipour S; Cusick SS; Fox JC Ann Emerg Med; 2010 Aug; 56(2):114-22. PubMed ID: 20138397 [TBL] [Abstract][Full Text] [Related]
20. Noninvasive monitoring of cardiac output in critically ill patients using transesophageal Doppler. Valtier B; Cholley BP; Belot JP; de la Coussaye JE; Mateo J; Payen DM Am J Respir Crit Care Med; 1998 Jul; 158(1):77-83. PubMed ID: 9655710 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]