These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

362 related articles for article (PubMed ID: 10705774)

  • 1. EOG correction: which regression should we use?
    Croft RJ; Barry RJ
    Psychophysiology; 2000 Jan; 37(1):123-5. PubMed ID: 10705774
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A test of four EOG correction methods using an improved validation technique.
    Pham TT; Croft RJ; Cadusch PJ; Barry RJ
    Int J Psychophysiol; 2011 Feb; 79(2):203-10. PubMed ID: 21034784
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Procedures for on-line minimizing of eyelid and vertical eye movement artefacts in the EEG].
    Schwind J; Gross M
    EEG EMG Z Elektroenzephalogr Elektromyogr Verwandte Geb; 1988 Jun; 19(2):96-100. PubMed ID: 3136003
    [TBL] [Abstract][Full Text] [Related]  

  • 4. One-channel EOG artifact correction: an analytic approach.
    Matthäus L; Pham T; Croft RJ
    Psychophysiology; 2008 Jul; 45(4):569-78. PubMed ID: 18503489
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Temporal stability of regression-based electrooculographic correction coefficients.
    Pham TT; Croft RJ; Cadusch PJ
    Psychophysiology; 2011 Jan; 48(1):96-101. PubMed ID: 20536903
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A fully automated correction method of EOG artifacts in EEG recordings.
    Schlögl A; Keinrath C; Zimmermann D; Scherer R; Leeb R; Pfurtscheller G
    Clin Neurophysiol; 2007 Jan; 118(1):98-104. PubMed ID: 17088100
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A comparative study of automatic techniques for ocular artifact reduction in spontaneous EEG signals based on clinical target variables: a simulation case.
    Romero S; Mañanas MA; Barbanoj MJ
    Comput Biol Med; 2008 Mar; 38(3):348-60. PubMed ID: 18222418
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Automatic correction of ocular artifacts in the EEG: a comparison of regression-based and component-based methods.
    Wallstrom GL; Kass RE; Miller A; Cohn JF; Fox NA
    Int J Psychophysiol; 2004 Jul; 53(2):105-19. PubMed ID: 15210288
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A model-based objective evaluation of eye movement correction in EEG recordings.
    Kierkels JJ; van Boxtel GJ; Vogten LL
    IEEE Trans Biomed Eng; 2006 Feb; 53(2):246-53. PubMed ID: 16485753
    [TBL] [Abstract][Full Text] [Related]  

  • 10. SNOAR: a new regression approach for the removal of ocular artifact from multi-channel electroencephalogram signals.
    Juyal R; Muthusamy H; Kumar N
    Med Biol Eng Comput; 2022 Dec; 60(12):3567-3583. PubMed ID: 36245020
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Removal of ocular artifact from the EEG: a review.
    Croft RJ; Barry RJ
    Neurophysiol Clin; 2000 Feb; 30(1):5-19. PubMed ID: 10740792
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Is ocular voltage propagation to the electroencephalogram frequency dependent?
    Pham TT; Croft RJ; Cadusch PJ
    Psychophysiology; 2009 Sep; 46(5):949-56. PubMed ID: 19497012
    [TBL] [Abstract][Full Text] [Related]  

  • 13. EOG correction: comparing different calibration methods, and determining the number of epochs required in a calibration average.
    Croft RJ; Barry RJ
    Clin Neurophysiol; 2000 Mar; 111(3):440-3. PubMed ID: 10699404
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Removal of the ocular artifacts from EEG data using a cascaded spatio-temporal processing.
    Liu T; Yao D
    Comput Methods Programs Biomed; 2006 Aug; 83(2):95-103. PubMed ID: 16884816
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Issues relating to the subtraction phase in EOG artefact correction of the EEG.
    Croft RJ; Barry RJ
    Int J Psychophysiol; 2002 Jun; 44(3):187-95. PubMed ID: 12031294
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Removing electroencephalographic artifacts by blind source separation.
    Jung TP; Makeig S; Humphries C; Lee TW; McKeown MJ; Iragui V; Sejnowski TJ
    Psychophysiology; 2000 Mar; 37(2):163-78. PubMed ID: 10731767
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A new regression-based method for the eye blinks artifacts correction in the EEG signal, without using any EOG channel.
    Di Flumeri G; Arico P; Borghini G; Colosimo A; Babiloni F
    Annu Int Conf IEEE Eng Med Biol Soc; 2016 Aug; 2016():3187-3190. PubMed ID: 28268985
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Automatic removal of high-amplitude artefacts from single-channel electroencephalograms.
    Teixeira AR; Tomé AM; Lang EW; Gruber P; Martins da Silva A
    Comput Methods Programs Biomed; 2006 Aug; 83(2):125-38. PubMed ID: 16876903
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Visual and computer-based detection of slow eye movements in overnight and 24-h EOG recordings.
    Magosso E; Ursino M; Zaniboni A; Provini F; Montagna P
    Clin Neurophysiol; 2007 May; 118(5):1122-33. PubMed ID: 17368090
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The removal of the eye-movement artifact from the EEG by regression analysis in the frequency domain.
    Woestenburg JC; Verbaten MN; Slangen JL
    Biol Psychol; 1983; 16(1-2):127-47. PubMed ID: 6850023
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 19.