BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

113 related articles for article (PubMed ID: 10707238)

  • 1. Material and design in haematogenous implant-associated infections in a rabbit model.
    Johansson A; Lindgren JU; Nord CE; Svensson O
    Injury; 1999 Dec; 30(10):651-7. PubMed ID: 10707238
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Titanium and steel fracture fixation plates with different surface topographies: Influence on infection rate in a rabbit fracture model.
    Metsemakers WJ; Schmid T; Zeiter S; Ernst M; Keller I; Cosmelli N; Arens D; Moriarty TF; Richards RG
    Injury; 2016 Mar; 47(3):633-9. PubMed ID: 26830128
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Local plate infections in a rabbit model.
    Johansson A; Lindgren JU; Nord CE; Svensson O
    Injury; 1999 Nov; 30(9):587-90. PubMed ID: 10707225
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The impact of thermal cycling on Staphylococcus aureus biofilm growth on stainless steel and titanium orthopaedic plates.
    Akens MK; Chien C; Katchky RN; Kreder HJ; Finkelstein J; Whyne CM
    BMC Musculoskelet Disord; 2018 Jul; 19(1):260. PubMed ID: 30049271
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Influence of the design for fixation implants on local infection: experimental study of dynamic compression plates versus point contact fixators in rabbits.
    Arens S; Eijer H; Schlegel U; Printzen G; Perren SM; Hansis M
    J Orthop Trauma; 1999; 13(7):470-6. PubMed ID: 10513968
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Influence of materials for fixation implants on local infection. An experimental study of steel versus titanium DCP in rabbits.
    Arens S; Schlegel U; Printzen G; Ziegler WJ; Perren SM; Hansis M
    J Bone Joint Surg Br; 1996 Jul; 78(4):647-51. PubMed ID: 8682836
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Influence of material and microtopography on the development of local infection in vivo: experimental investigation in rabbits.
    Moriarty TF; Debefve L; Boure L; Campoccia D; Schlegel U; Richards RG
    Int J Artif Organs; 2009 Sep; 32(9):663-70. PubMed ID: 19882548
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A histologic analysis of the effects of stainless steel and titanium implants adjacent to tendons: an experimental rabbit study.
    Nazzal A; Lozano-Calderón S; Jupiter JB; Rosenzweig JS; Randolph MA; Lee SG
    J Hand Surg Am; 2006 Sep; 31(7):1123-30. PubMed ID: 16945714
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The influence of the chemical composition and surface of the implant on infection.
    Cordero J; Munuera L; Folgueira MD
    Injury; 1996; 27 Suppl 3():SC34-7. PubMed ID: 9039352
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Strain distribution in plated and unplated sheep tibia an in vivo experiment.
    Gautier E; Perren SM; Cordey J
    Injury; 2000 Sep; 31 Suppl 3():C37-44. PubMed ID: 11052379
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Efficacy of a norvancomycin-loaded, PDLLA-coated plate in preventing early infection of rabbit tibia fracture.
    Fei J; Yu HJ; Pan CJ; Zhao CH; Zhou YG; Wang Y
    Orthopedics; 2010 May; 33(5):. PubMed ID: 20506956
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Rabbit model of
    Gordon O; Miller RJ; Thompson JM; Ordonez AA; Klunk MH; Dikeman DA; Joyce DP; Ruiz-Bedoya CA; Miller LS; Jain SK
    Dis Model Mech; 2020 Jul; 13(7):. PubMed ID: 32586832
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Bone remodelling after internal fixation with different stiffness plates: ultrastructural investigation.
    Chen YQ; Dai KR; Qiu SJ; Zhu ZA
    Chin Med J (Engl); 1994 Oct; 107(10):766-70. PubMed ID: 7835104
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Effects of implant material and plate design on tendon function and morphology.
    Cohen MS; Turner TM; Urban RM
    Clin Orthop Relat Res; 2006 Apr; 445():81-90. PubMed ID: 16601410
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A novel spinal implant infection model in rabbits.
    Poelstra KA; Barekzi NA; Grainger DW; Gristina AG; Schuler TC
    Spine (Phila Pa 1976); 2000 Feb; 25(4):406-10. PubMed ID: 10707383
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The effects of metal plates on post-traumatic remodelling and bone mass.
    Uhthoff HK; Finnegan M
    J Bone Joint Surg Br; 1983 Jan; 65(1):66-71. PubMed ID: 6822605
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Cathodic Electrical Stimulation Combined With Vancomycin Enhances Treatment of Methicillin-resistant Staphylococcus aureus Implant-associated Infections.
    Nodzo S; Tobias M; Hansen L; Luke-Marshall NR; Cole R; Wild L; Campagnari AA; Ehrensberger MT
    Clin Orthop Relat Res; 2015 Sep; 473(9):2856-64. PubMed ID: 25825157
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A biomechanical evaluation of different plates for fixation of canine radial osteotomies.
    Jain R; Podworny N; Hearn T; Richards RR; Schemitsch EH
    J Trauma; 1998 Jan; 44(1):193-7. PubMed ID: 9464772
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Implant Material, Type of Fixation at the Shaft, and Position of Plate Modify Biomechanics of Distal Femur Plate Osteosynthesis.
    Kandemir U; Augat P; Konowalczyk S; Wipf F; von Oldenburg G; Schmidt U
    J Orthop Trauma; 2017 Aug; 31(8):e241-e246. PubMed ID: 28394844
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Cathodic Voltage-controlled Electrical Stimulation Plus Prolonged Vancomycin Reduce Bacterial Burden of a Titanium Implant-associated Infection in a Rodent Model.
    Nodzo SR; Tobias M; Ahn R; Hansen L; Luke-Marshall NR; Howard C; Wild L; Campagnari AA; Ehrensberger MT
    Clin Orthop Relat Res; 2016 Jul; 474(7):1668-75. PubMed ID: 26801677
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.