200 related articles for article (PubMed ID: 10708174)
1. Autotriggering caused by cardiogenic oscillation during flow-triggered mechanical ventilation.
Imanaka H; Nishimura M; Takeuchi M; Kimball WR; Yahagi N; Kumon K
Crit Care Med; 2000 Feb; 28(2):402-7. PubMed ID: 10708174
[TBL] [Abstract][Full Text] [Related]
2. Flow triggering, pressure triggering, and autotriggering during mechanical ventilation.
Hill LL; Pearl RG
Crit Care Med; 2000 Feb; 28(2):579-81. PubMed ID: 10708209
[No Abstract] [Full Text] [Related]
3. Exhaled tidal volume overestimation in mechanically ventilated patients with large cardiogenic oscillation.
Imanaka H; Takeuchi M; Tachibana K; Nishimura M
Crit Care Med; 2004 Jul; 32(7):1546-9. PubMed ID: 15241100
[TBL] [Abstract][Full Text] [Related]
4. Effect of Cardiogenic Oscillations on Trigger Delay During Pressure Support Ventilation.
Plens GM; Morais CC; Nakamura MA; Souza PN; Amato MB; Tucci MR; Costa EL
Respir Care; 2018 Jul; 63(7):865-872. PubMed ID: 29895701
[TBL] [Abstract][Full Text] [Related]
5. Influence of pressure- and flow-triggered synchronous intermittent mandatory ventilation on inspiratory muscle work.
Sassoon CS; Del Rosario N; Fei R; Rheeman CH; Gruer SE; Mahutte CK
Crit Care Med; 1994 Dec; 22(12):1933-41. PubMed ID: 7988129
[TBL] [Abstract][Full Text] [Related]
6. Effects of the flow waveform method of triggering and cycling on patient-ventilator interaction during pressure support.
Prinianakis G; Kondili E; Georgopoulos D
Intensive Care Med; 2003 Nov; 29(11):1950-9. PubMed ID: 12665996
[TBL] [Abstract][Full Text] [Related]
7. Detection of Ventilator Autotriggering by an Esophageal Catheter Used to Monitor the Neural Input and Diaphragm Excitation.
Sangha H; Whitacre T
J Intensive Care Med; 2017 Feb; 32(2):170-173. PubMed ID: 27798315
[TBL] [Abstract][Full Text] [Related]
8. Comparison of pressure- and flow-triggered pressure-support ventilation on weaning parameters in patients recovering from acute respiratory failure.
Tütüncü AS; Cakar N; Camci E; Esen F; Telci L; Akpir K
Crit Care Med; 1997 May; 25(5):756-60. PubMed ID: 9187592
[TBL] [Abstract][Full Text] [Related]
9. Autotriggering during pressure support ventilation due to cardiogenic oscillations.
Sheikh E; Maguire DP; Gratch D
Anesth Analg; 2009 Aug; 109(2):470-2. PubMed ID: 19608820
[TBL] [Abstract][Full Text] [Related]
10. Cardiogenic oscillation and ventilator autotriggering in brain-dead patients: a case series.
Arbour R
Am J Crit Care; 2009 Sep; 18(5):496, 488-95. PubMed ID: 19723871
[TBL] [Abstract][Full Text] [Related]
11. Expiratory tidal volume displayed on Bird 8400 STi can exceed the preset tidal volume due to cardiogenic oscillation: a lung model study.
Imanaka H; Takeuchi M; Tachibana K; Nishimura M
J Anesth; 2004; 18(4):313-5. PubMed ID: 15549478
[TBL] [Abstract][Full Text] [Related]
12. Intratracheal pulmonary ventilation in a rabbit lung injury model: continuous airway pressure monitoring and gas exchange efficacy.
Hon EK; Hultquist KA; Loescher T; Raszynski A; Torbati D; Tabares C; Wolfsdorf J
Crit Care Med; 2000 Jul; 28(7):2480-5. PubMed ID: 10921582
[TBL] [Abstract][Full Text] [Related]
13. Monitoring interactions between spontaneous respiration and mechanical inflations in preterm neonates.
Bignall S; Dixon P; Quinn C; Kitney R
Crit Care Med; 1997 Mar; 25(3):545-53. PubMed ID: 9118675
[TBL] [Abstract][Full Text] [Related]
14. Randomized, prospective trial of bilevel versus continuous positive airway pressure in acute pulmonary edema.
Mehta S; Jay GD; Woolard RH; Hipona RA; Connolly EM; Cimini DM; Drinkwine JH; Hill NS
Crit Care Med; 1997 Apr; 25(4):620-8. PubMed ID: 9142026
[TBL] [Abstract][Full Text] [Related]
15. Effect of synchronized intermittent mandatory ventilation on respiratory workload in infants after cardiac surgery.
Imanaka H; Nishimura M; Miyano H; Uemura H; Yagihara T
Anesthesiology; 2001 Oct; 95(4):881-8. PubMed ID: 11605928
[TBL] [Abstract][Full Text] [Related]
16. Breathing measurement reduces false-negative classification of tachypneic preextubation trial failures.
DeHaven CB; Kirton OC; Morgan JP; Hart AM; Shatz DV; Civetta JM
Crit Care Med; 1996 Jun; 24(6):976-80. PubMed ID: 8681601
[TBL] [Abstract][Full Text] [Related]
17. Neurally triggered breaths have reduced response time, work of breathing, and asynchrony compared with pneumatically triggered breaths in a recovering animal model of lung injury.
Heulitt MJ; Clement KC; Holt SJ; Thurman TL; Jo CH
Pediatr Crit Care Med; 2012 May; 13(3):e195-203. PubMed ID: 22079957
[TBL] [Abstract][Full Text] [Related]
18. Patient-ventilator interactions during partial ventilatory support: a preliminary study comparing the effects of adaptive support ventilation with synchronized intermittent mandatory ventilation plus inspiratory pressure support.
Tassaux D; Dalmas E; Gratadour P; Jolliet P
Crit Care Med; 2002 Apr; 30(4):801-7. PubMed ID: 11940749
[TBL] [Abstract][Full Text] [Related]
19. Pressure-controlled, inverse ratio ventilation that avoids air trapping in the adult respiratory distress syndrome.
Armstrong BW; MacIntyre NR
Crit Care Med; 1995 Feb; 23(2):279-85. PubMed ID: 7867353
[TBL] [Abstract][Full Text] [Related]
20. Intrapulmonary percussive ventilation superimposed on conventional mechanical ventilation: comparison of volume controlled and pressure controlled modes.
Riffard G; Buzenet J; Guérin C
Respir Care; 2014 Jul; 59(7):1116-22. PubMed ID: 24255158
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]