803 related articles for article (PubMed ID: 10721317)
21. Calcaneal quantitative ultrasound has a role in out ruling low bone mineral density in axial spondyloarthropathy.
Fitzgerald GE; Anachebe T; McCarroll KG; O'Shea F
Clin Rheumatol; 2020 Jun; 39(6):1971-1979. PubMed ID: 31953568
[TBL] [Abstract][Full Text] [Related]
22. Genetic and environmental contributions to the association between quantitative ultrasound and bone mineral density measurements: a twin study.
Howard GM; Nguyen TV; Harris M; Kelly PJ; Eisman JA
J Bone Miner Res; 1998 Aug; 13(8):1318-27. PubMed ID: 9718201
[TBL] [Abstract][Full Text] [Related]
23. Quantitative bone ultrasound at phalanges and calcaneus in osteoporotic postmenopausal women: influence of age and measurement site.
Camozzi V; De Terlizzi F; Zangari M; Luisetto G
Ultrasound Med Biol; 2007 Jul; 33(7):1039-45. PubMed ID: 17445968
[TBL] [Abstract][Full Text] [Related]
24. Discriminatory Performance of the Calcaneal Quantitative Ultrasound and Osteoporosis Self-Assessment Tool to Select Older Women for Dual-Energy X-ray Absorptiometry.
McLeod KM; Johnson S; Rasali D; Verma A
J Clin Densitom; 2015; 18(2):157-64. PubMed ID: 25937306
[TBL] [Abstract][Full Text] [Related]
25. Quantitative ultrasound measurements of the tibia and calcaneus in comparison with DXA measurements at various skeletal sites.
Tromp AM; Smit JH; Deeg DJ; Lips P
Osteoporos Int; 1999; 9(3):230-5. PubMed ID: 10450412
[TBL] [Abstract][Full Text] [Related]
26. Quantitative heel ultrasound as a predictor for osteoporosis.
Naganathan V; March L; Hunter D; Pocock NA; Markovey J; Sambrook PN
Med J Aust; 1999 Sep; 171(6):297-300. PubMed ID: 10560444
[TBL] [Abstract][Full Text] [Related]
27. Discrimination of hip fractures by quantitative ultrasound of the phalanges and the calcaneus and dual X-ray absorptiometry.
Damilakis J; Papadokostakis G; Perisinakis K; Maris T; Dimitriou P; Hadjipavlou A; Gourtsoyiannis N
Eur J Radiol; 2004 Jun; 50(3):268-72. PubMed ID: 15145486
[TBL] [Abstract][Full Text] [Related]
28. [Bone density measurement: quantitative ultrasound of the calcaneus and distal radius. A comparison with dual spectrum X-ray absorptiometry].
Boyanov M; Shinkov A; Nestorova R
Dtsch Med Wochenschr; 2007 Apr; 132(16):869-73. PubMed ID: 17443442
[TBL] [Abstract][Full Text] [Related]
29. Prediction of vertebral strength in vitro by spinal bone densitometry and calcaneal ultrasound.
Cheng XG; Nicholson PH; Boonen S; Lowet G; Brys P; Aerssens J; Van der Perre G; Dequeker J
J Bone Miner Res; 1997 Oct; 12(10):1721-8. PubMed ID: 9333134
[TBL] [Abstract][Full Text] [Related]
30. Performance of calcaneus quantitative ultrasound and dual-energy X-ray absorptiometry in the discrimination of prevalent asymptomatic osteoporotic fractures in postmenopausal women.
El Maghraoui A; Morjane F; Mounach A; Ghazi M; Nouijai A; Achemlal L; Bezza A; Ghozlani I
Rheumatol Int; 2009 Mar; 29(5):551-6. PubMed ID: 18953537
[TBL] [Abstract][Full Text] [Related]
31. Contact quantitative ultrasound: an evaluation of precision, fracture discrimination, age-related bone loss and applicability of the WHO criteria.
Frost ML; Blake GM; Fogelman I
Osteoporos Int; 1999; 10(6):441-9. PubMed ID: 10663343
[TBL] [Abstract][Full Text] [Related]
32. Quantitative ultrasound and dual-energy X-ray absorptiometry in the prediction of fragility fracture in men.
Gonnelli S; Cepollaro C; Gennari L; Montagnani A; Caffarelli C; Merlotti D; Rossi S; Cadirni A; Nuti R
Osteoporos Int; 2005 Aug; 16(8):963-8. PubMed ID: 15599495
[TBL] [Abstract][Full Text] [Related]
33. The role of quantitative ultrasound in predicting osteoporosis defined by dual X-ray absorptiometry.
Cetin A; Ertürk H; Celiker R; Sivri A; Hasçelik Z
Rheumatol Int; 2001 Feb; 20(2):55-9. PubMed ID: 11269533
[TBL] [Abstract][Full Text] [Related]
34. [Quantitative ultrasound scans of the calcaneus: a useful tool for screening osteoporosis in patients with connective tissue disease].
Wang Y; Zhou W; Hao YJ; Li GT; Deng XR; Zhao J; Zhang ZL
Beijing Da Xue Xue Bao Yi Xue Ban; 2013 Oct; 45(5):766-9. PubMed ID: 24136275
[TBL] [Abstract][Full Text] [Related]
35. Unique and common genetic effects between bone mineral density and calcaneal quantitative ultrasound measures: the Fels Longitudinal Study.
Lee M; Czerwinski SA; Choh AC; Demerath EW; Sun SS; Chumlea WC; Towne B; Siervogel RM
Osteoporos Int; 2006; 17(6):865-71. PubMed ID: 16541205
[TBL] [Abstract][Full Text] [Related]
36. Calcaneus ultrasonometry and dual-energy X-ray absorptiometry for the evaluation of vertebral fracture risk.
Frediani B; Acciai C; Falsetti P; Baldi F; Filippou G; Siagkri C; Spreafico A; Galeazzi M; Marcolongo R
Calcif Tissue Int; 2006 Oct; 79(4):223-9. PubMed ID: 16969597
[TBL] [Abstract][Full Text] [Related]
37. Discriminatory ability of quantitative ultrasound measurements is similar to dual-energy X-ray absorptiometry in a Brazilian women population with osteoporotic fracture.
Pinheiro MM; Castro CH; Frisoli A; Szejnfeld VL
Calcif Tissue Int; 2003 Dec; 73(6):555-64. PubMed ID: 14517710
[TBL] [Abstract][Full Text] [Related]
38. Identifying postmenopausal women with osteoporosis by calcaneal ultrasound, metacarpal digital X-ray radiogrammetry and phalangeal radiographic absorptiometry: a comparative study.
Boonen S; Nijs J; Borghs H; Peeters H; Vanderschueren D; Luyten FP
Osteoporos Int; 2005 Jan; 16(1):93-100. PubMed ID: 15197540
[TBL] [Abstract][Full Text] [Related]
39. Quantitative ultrasound and fracture risk prediction in non-osteoporotic men and women as defined by WHO criteria.
Chan MY; Nguyen ND; Center JR; Eisman JA; Nguyen TV
Osteoporos Int; 2013 Mar; 24(3):1015-22. PubMed ID: 22878531
[TBL] [Abstract][Full Text] [Related]
40. Influence of region of interest and bone size on calcaneal BMD: implications for the accuracy of quantitative ultrasound assessments at the calcaneus.
Cheng S; Njeh CF; Fan B; Cheng X; Hans D; Wang L; Fuerst T; Genant HK
Br J Radiol; 2002 Jan; 75(889):59-68. PubMed ID: 11806960
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]