2. High dose rate intracoronary radiation for inhibition of neointimal formation in the stented and balloon-injured porcine models of restenosis: angiographic, morphometric, and histopathologic analyses. Mazur W; Ali MN; Khan MM; Dabaghi SF; DeFelice CA; Paradis P; Butler EB; Wright AE; Fajardo LF; French BA; Raizner AE Int J Radiat Oncol Biol Phys; 1996 Nov; 36(4):777-88. PubMed ID: 8960503 [TBL] [Abstract][Full Text] [Related]
3. Experimental evaluation of a short transitional edge protection balloon for intracoronary stent deployment. Carter AJ; Lee DP; Suzuki T; Bailey L; Lansky A; Jones R; Virmani R Catheter Cardiovasc Interv; 2000 Sep; 51(1):112-9. PubMed ID: 10973033 [TBL] [Abstract][Full Text] [Related]
4. Stent design favorably influences the vascular response in normal porcine coronary arteries. Carter AJ; Scott D; Rahdert D; Bailey L; De Vries J ; Ayerdi K; Turnlund T; Jones R; Virmani R; Fischell TA J Invasive Cardiol; 1999 Mar; 11(3):127-34. PubMed ID: 10745499 [TBL] [Abstract][Full Text] [Related]
5. Restenosis and the proportional neointimal response to coronary artery injury: results in a porcine model. Schwartz RS; Huber KC; Murphy JG; Edwards WD; Camrud AR; Vlietstra RE; Holmes DR J Am Coll Cardiol; 1992 Feb; 19(2):267-74. PubMed ID: 1732351 [TBL] [Abstract][Full Text] [Related]
6. Coronary stenting with a novel stainless steel balloon-expandable stent: determinants of neointimal formation and changes in arterial geometry after placement in an atherosclerotic model. Carter AJ; Laird JR; Kufs WM; Bailey L; Hoopes TG; Reeves T; Farb A; Virmani R J Am Coll Cardiol; 1996 Apr; 27(5):1270-7. PubMed ID: 8609355 [TBL] [Abstract][Full Text] [Related]
7. The effects of uncontrolled hyperglycemia on thrombosis and formation of neointima after coronary stent placement in a novel diabetic porcine model of restenosis. Carter AJ; Bailey L; Devries J; Hubbard B Coron Artery Dis; 2000 Sep; 11(6):473-9. PubMed ID: 10966133 [TBL] [Abstract][Full Text] [Related]
8. Inhibition of neointima formation by tranilast in pig coronary arteries after balloon angioplasty and stent implantation. Ishiwata S; Verheye S; Robinson KA; Salame MY; de Leon H; King SB; Chronos NA J Am Coll Cardiol; 2000 Apr; 35(5):1331-7. PubMed ID: 10758977 [TBL] [Abstract][Full Text] [Related]
9. Morphologic characteristics of lesion formation and time course of smooth muscle cell proliferation in a porcine proliferative restenosis model. Carter AJ; Laird JR; Farb A; Kufs W; Wortham DC; Virmani R J Am Coll Cardiol; 1994 Nov; 24(5):1398-405. PubMed ID: 7930266 [TBL] [Abstract][Full Text] [Related]
10. Stent design related neointimal tissue proliferation in human coronary arteries; an intravascular ultrasound study. Hoffmann R; Jansen C; König A; Haager PK; Kerckhoff G; vom Dahl J; Klauss V; Hanrath P; Mudra H Eur Heart J; 2001 Nov; 22(21):2007-14. PubMed ID: 11603908 [TBL] [Abstract][Full Text] [Related]
11. Increasing arterial wall injury after long-term implantation of two types of stent in a porcine coronary model. Hofma SH; Whelan DM; van Beusekom HM; Verdouw PD; van der Giessen WJ Eur Heart J; 1998 Apr; 19(4):601-9. PubMed ID: 9597409 [TBL] [Abstract][Full Text] [Related]
12. Stents covered by an autologous arterial graft in porcine coronary arteries: feasibility, vascular injury and effect on neointimal hyperplasia. Stefanadis C; Toutouzas K; Tsiamis E; Vlachopoulos C; Vaina S; Tsekoura D; Haldi L; Stefanadi E; Gravanis M; Toutouzas P Cardiovasc Res; 1999 Feb; 41(2):433-42. PubMed ID: 10341842 [TBL] [Abstract][Full Text] [Related]
13. Coronary intimal proliferation after balloon injury and stenting in swine: an animal model of restenosis. Karas SP; Gravanis MB; Santoian EC; Robinson KA; Anderberg KA; King SB J Am Coll Cardiol; 1992 Aug; 20(2):467-74. PubMed ID: 1634687 [TBL] [Abstract][Full Text] [Related]
14. In-stent restenosis: contributions of inflammatory responses and arterial injury to neointimal hyperplasia. Kornowski R; Hong MK; Tio FO; Bramwell O; Wu H; Leon MB J Am Coll Cardiol; 1998 Jan; 31(1):224-30. PubMed ID: 9426044 [TBL] [Abstract][Full Text] [Related]
15. Influence of stent design and deployment technique on neointima formation and vascular remodeling. König A; Schiele TM; Rieber J; Theisen K; Mudra H; Klauss V Z Kardiol; 2002; 91 Suppl 3():98-102. PubMed ID: 12641022 [TBL] [Abstract][Full Text] [Related]
16. Restenosis is not associated with stent length in a pig model of coronary stent implantation. Koutouzis M; Papalois A; Kyrzopoulos S; Dafnomili P; Kyriakides ZS Cardiol J; 2008; 15(5):458-62. PubMed ID: 18810722 [TBL] [Abstract][Full Text] [Related]
17. Small stent size and intimal hyperplasia contribute to restenosis: a volumetric intravascular ultrasound analysis. Dussaillant GR; Mintz GS; Pichard AD; Kent KM; Satler LF; Popma JJ; Wong SC; Leon MB J Am Coll Cardiol; 1995 Sep; 26(3):720-4. PubMed ID: 7642865 [TBL] [Abstract][Full Text] [Related]
18. Tetramethylpyrazine-eluting stents prevented in-stent restenosis in a porcine model. Ma G; Ding S; Feng Y; Shen C; Chen L; Chen Z J Cardiovasc Pharmacol; 2007 Aug; 50(2):201-5. PubMed ID: 17703137 [TBL] [Abstract][Full Text] [Related]
19. Differences in Vascular Response between Balloon Overstretch and Stent Overexpansion in Nonatherosclerotic Porcine Coronary Arteries. Mitsutake Y; Reifart J; Pyun WB; Lyons JK; Deuse T; Schrepfer S; Ikeno F Comp Med; 2017 Aug; 67(4):350-355. PubMed ID: 28830582 [TBL] [Abstract][Full Text] [Related]
20. A comparison of four stent designs on arterial injury, cellular proliferation, neointima formation, and arterial dimensions in an experimental porcine model. Taylor AJ; Gorman PD; Kenwood B; Hudak C; Tashko G; Virmani R Catheter Cardiovasc Interv; 2001 Jul; 53(3):420-5. PubMed ID: 11458427 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]