These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

138 related articles for article (PubMed ID: 10738079)

  • 1. Evaluation of the dose uniformity for double-plane high dose rate interstitial breast implants with the use of dose reference points and dose non-uniformity ratio.
    Major T; Polgár C; Somogyi A; Németh G
    Radiother Oncol; 2000 Mar; 54(3):213-20. PubMed ID: 10738079
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Conformality and homogeneity of dose distributions in interstitial implants at idealized target volumes: a comparison between the Paris and dose-point optimized systems.
    Major T; Polgár C; Fodor J; Somogyi A; Németh G
    Radiother Oncol; 2002 Jan; 62(1):103-11. PubMed ID: 11830318
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Optimization of interstitial volume implants.
    Kolkman-Deurloo IK; Visser AG; Niël CG; Driver N; Levendag PC
    Radiother Oncol; 1994 Jun; 31(3):229-39. PubMed ID: 8066206
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A method to improve the dose distribution of interstitial breast implants using geometrically optimized stepping source techniques and dose normalization.
    Pieters BR; Saarnak AE; Steggerda MJ; Borger JH
    Radiother Oncol; 2001 Jan; 58(1):63-70. PubMed ID: 11165683
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Intraoperative optimization of needle placement and dwell times for conformal prostate brachytherapy.
    Edmundson GK; Yan D; Martinez AA
    Int J Radiat Oncol Biol Phys; 1995 Dec; 33(5):1257-63. PubMed ID: 7493850
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Consequences of optimization in PDR brachytherapy--is a routine geometrical optimization recommendable?
    Berns C; Fritz P; Hensley FW; Wannenmacher M
    Int J Radiat Oncol Biol Phys; 1997 Mar; 37(5):1171-80. PubMed ID: 9169828
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Dose uniformity in a planar interstitial implant system.
    Zwicker RD; Schmidt-Ullrich R
    Int J Radiat Oncol Biol Phys; 1995 Jan; 31(1):149-55. PubMed ID: 7995746
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Effect of geometrical optimization on the treatment volumes and the dose homogeneity of biplane interstitial brachytherapy implants.
    Anacak Y; Esassolak M; Aydin A; Aras A; Olacak I; Haydaroğlu A
    Radiother Oncol; 1997 Oct; 45(1):71-6. PubMed ID: 9364634
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Evaluation of HDR interstitial breast implants planned by conventional and optimized CT-based dosimetry systems with respect to dose homogeneity and conformality.
    Major T; Fodor J; Takácsi-Nagy Z; Agoston P; Polgár C
    Strahlenther Onkol; 2005 Feb; 181(2):89-96. PubMed ID: 15702297
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A comparison between tandem and ovoids and interstitial gynecologic template brachytherapy dosimetry using a hypothetical computer model.
    Hsu IC; Speight J; Hai J; Vigneault E; Phillips T; Pouliot J
    Int J Radiat Oncol Biol Phys; 2002 Feb; 52(2):538-43. PubMed ID: 11872302
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Dose optimization of intra-operative high dose rate interstitial brachytherapy implants for soft tissue sarcoma.
    Jamema SV; Sharma PK; Sharma D; Laskar S; Deshpande DD; Shrivastava SK
    J Cancer Res Ther; 2009; 5(4):240-6. PubMed ID: 20160356
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Optimization of planar high-dose-rate implants.
    Zwicker RD; Arthur DW; Kavanagh BD; Mohan R; Schmidt-Ullrich RK
    Int J Radiat Oncol Biol Phys; 1999 Jul; 44(5):1171-7. PubMed ID: 10421552
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Dose-volume analysis for quality assurance of interstitial brachytherapy for breast cancer.
    Vicini FA; Kestin LL; Edmundson GK; Jaffray DA; Wong JW; Kini VR; Chen PY; Martinez AA
    Int J Radiat Oncol Biol Phys; 1999 Oct; 45(3):803-10. PubMed ID: 10524437
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Evaluation of geometrically optimized single- and double-plane interstitial high dose rate implants with respect to conformality and homogeneity.
    Major T; Polgár C; Fodor J; Takácsi-Nagy Z; Mangel L; Németh G
    Acta Oncol; 2003; 42(1):15-21. PubMed ID: 12665326
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Adaptation of the CVT algorithm for catheter optimization in high dose rate brachytherapy.
    Poulin E; Fekete CA; Létourneau M; Fenster A; Pouliot J; Beaulieu L
    Med Phys; 2013 Nov; 40(11):111724. PubMed ID: 24320432
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Impact of inter- and intra-observer variabilities of catheter reconstruction on multi-catheter interstitial brachytherapy of breast cancer patients.
    Kallis K; Kaltsas T; Kreppner S; Lotter M; Strnad V; Fietkau R; Bert C
    Radiother Oncol; 2019 Jun; 135():25-32. PubMed ID: 31015167
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Treatment volume and dose optimization of MammoSite breast brachytherapy applicator.
    Dickler A; Kirk M; Choo J; Hsi WC; Chu J; Dowlatshahi K; Francescatti D; Nguyen C
    Int J Radiat Oncol Biol Phys; 2004 Jun; 59(2):469-74. PubMed ID: 15145164
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Dose volume assessment of high dose rate 192Ir endobronchial implants.
    Saw CB; Korb LJ; Pawlicki T; Wu A
    Int J Radiat Oncol Biol Phys; 1996 Mar; 34(4):917-22. PubMed ID: 8598371
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The evaluation of optimized implants for idealized implant geometries.
    Low DA; Williamson JF
    Med Phys; 1995 Sep; 22(9):1477-85. PubMed ID: 8531878
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Improving the dosimetric coverage of interstitial high-dose-rate breast implants.
    Kestin LL; Jaffray DA; Edmundson GK; Martinez AA; Wong JW; Kini VR; Chen PY; Vicini FA
    Int J Radiat Oncol Biol Phys; 2000 Jan; 46(1):35-43. PubMed ID: 10656370
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.