These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
113 related articles for article (PubMed ID: 10744328)
1. Automated liquid chromatographic determination of atenolol in plasma using dialysis and trace enrichment on a cation-exchange precolumn for sample handling. Chiap P; Buraglia BM; Ceccato A; Hubert P; Crommen J J Chromatogr B Biomed Sci Appl; 2000 Feb; 739(1):205-17. PubMed ID: 10744328 [TBL] [Abstract][Full Text] [Related]
2. Development and validation of an automated method for the liquid chromatographic determination of sotalol in plasma using dialysis and trace enrichment on a cation-exchange pre-column as on-line sample preparation. Chiap P; Ceccato A; Miralles Buraglia B; Boulanger B; Hubert P; Crommen J J Pharm Biomed Anal; 2001 Mar; 24(5-6):801-14. PubMed ID: 11248472 [TBL] [Abstract][Full Text] [Related]
3. Determination of albendazole and its main metabolites in ovine plasma by liquid chromatography with dialysis as an integrated sample preparation technique. Chiap P; Evrard B; Bimazubute MA; de Tullio P; Hubert P; Delattre L; Crommen J J Chromatogr A; 2000 Feb; 870(1-2):121-34. PubMed ID: 10722069 [TBL] [Abstract][Full Text] [Related]
4. Enantioselective determination of oxprenolol in human plasma using dialysis coupled on-line to reversed-phase chiral liquid chromatography. Ceccato A; Toussaint B; Chiap P; Hubert P; Crommen J J Pharm Biomed Anal; 1997 Jun; 15(9-10):1365-74. PubMed ID: 9226565 [TBL] [Abstract][Full Text] [Related]
5. Automated determination of verapamil and norverapamil in human plasma with on-line coupling of dialysis to high-performance liquid chromatography and fluorometric detection. Ceccato A; Chiap P; Hubert P; Toussaint B; Crommen J J Chromatogr A; 1996 Oct; 750(1-2):351-60. PubMed ID: 8938391 [TBL] [Abstract][Full Text] [Related]
6. Strategy for the development of automated methods involving dialysis and trace enrichment as on-line sample preparation for the determination of basic drugs in plasma by liquid chromatography. Chiap P; Hubert P; Crommen J J Chromatogr A; 2002 Mar; 948(1-2):151-61. PubMed ID: 12831192 [TBL] [Abstract][Full Text] [Related]
7. Fully automated LC method for the determination of sotalol in human plasma using restricted access material with cation exchange properties for sample clean-up. Rbeida O; Christiaens B; Chiap P; Hubert P; Lubda D; Boos KS; Crommen J J Pharm Biomed Anal; 2003 Aug; 32(4-5):829-38. PubMed ID: 12899969 [TBL] [Abstract][Full Text] [Related]
8. Fully automated method for the liquid chromatographic determination of cyproterone acetate in plasma using restricted access material for sample pre-treatment. Christiaens B; Chiap P; Rbeida O; Cello D; Crommen J; Hubert P J Chromatogr B Analyt Technol Biomed Life Sci; 2003 Sep; 795(1):73-82. PubMed ID: 12957171 [TBL] [Abstract][Full Text] [Related]
9. Direct injection of large volumes of plasma/serum on a new biocompatible extraction column for the determination of atenolol, propranolol and ibuprofen. Mechanisms for the improvement of chromatographic performance. Hermansson J; Grahn A; Hermansson I J Chromatogr A; 1998 Feb; 797(1-2):251-63. PubMed ID: 9542118 [TBL] [Abstract][Full Text] [Related]
10. Simultaneous determination of methylphenobarbital enantiomers and phenobarbital in human plasma by on-line coupling of an achiral precolumn to a chiral liquid chromatographic column. Ceccato A; Boulanger B; Chiap P; Hubert P; Crommen J J Chromatogr A; 1998 Sep; 819(1-2):143-53. PubMed ID: 9781418 [TBL] [Abstract][Full Text] [Related]
11. Fully automated method for the liquid chromatographic-tandem mass spectrometric determination of cyproterone acetate in human plasma using restricted access material for on-line sample clean-up. Christiaens B; Fillet M; Chiap P; Rbeida O; Ceccato A; Streel B; De Graeve J; Crommen J; Hubert P J Chromatogr A; 2004 Nov; 1056(1-2):105-10. PubMed ID: 15595539 [TBL] [Abstract][Full Text] [Related]
12. Stereoselective determination of unchanged and glucuroconjugated eliprodil, a new anti-ischaemic drug, in human plasma and urine by precolumn derivatization and column-switching high-performance liquid chromatography with fluorescence detection. Malavasi B; Ripamonti M; Rouchouse A; Ascalone V J Chromatogr A; 1996 Apr; 729(1-2):323-33. PubMed ID: 9004957 [TBL] [Abstract][Full Text] [Related]
13. Two reproducible and sensitive liquid chromatographic methods to quantify atenolol and propranolol in human plasma and determination of their associated analytical error functions. Braza AJ; Modamio P; Mariño EL J Chromatogr B Biomed Sci Appl; 2000 Feb; 738(2):225-31. PubMed ID: 10718640 [TBL] [Abstract][Full Text] [Related]
14. Hydrophilic interaction liquid chromatographic tandem mass spectrometric determination of atenolol in human plasma. Li W; Li Y; Francisco DT; Naidong W Biomed Chromatogr; 2005 Jun; 19(5):385-93. PubMed ID: 15651086 [TBL] [Abstract][Full Text] [Related]
15. Integrated on-line sample clean-up using cation exchange restricted access sorbent for the LC determination of atropine in human plasma coupled to UV detection. Rbeida O; Christiaens B; Hubert P; Lubda D; Boos KS; Crommen J; Chiap P J Pharm Biomed Anal; 2005 Jan; 36(5):947-54. PubMed ID: 15620518 [TBL] [Abstract][Full Text] [Related]
16. Quantitative determination of atenolol in dried blood spot samples by LC-HRMS: a potential method for assessing medication adherence. Lawson G; Cocks E; Tanna S J Chromatogr B Analyt Technol Biomed Life Sci; 2012 May; 897():72-9. PubMed ID: 22552005 [TBL] [Abstract][Full Text] [Related]
17. Chiral assay of atenolol present in microdialysis and plasma samples of rats using chiral CBH as stationary phase. Fornstedt T; Hesselgren AM; Johansson M Chirality; 1997; 9(4):329-34. PubMed ID: 9275311 [TBL] [Abstract][Full Text] [Related]
18. Automated method for the determination of a new matrix metalloproteinase inhibitor in ovine plasma and serum by coupling of restricted access material for on-line sample clean-up to liquid chromatography. Chiap P; Piette M; Evrard B; Frankenne F; Christiaens B; Piel G; Cataldo D; Foidart JM; Delattre L; Crommen J; Hubert P J Chromatogr B Analyt Technol Biomed Life Sci; 2005 Mar; 817(1):109-17. PubMed ID: 15680794 [TBL] [Abstract][Full Text] [Related]
19. Automated determination of pirlindole enantiomers in plasma by on-line coupling of a pre-column packed with restricted access material to a chiral liquid chromatographic column. Chiap P; Ceccato A; Gora R; Hubert P; Géczy J; Crommen J J Pharm Biomed Anal; 2002 Jan; 27(3-4):447-55. PubMed ID: 11755746 [TBL] [Abstract][Full Text] [Related]
20. Analytical approach to determining human biogenic amines and their metabolites using eVol microextraction in packed syringe coupled to liquid chromatography mass spectrometry method with hydrophilic interaction chromatography column. Konieczna L; Roszkowska A; Synakiewicz A; Stachowicz-Stencel T; Adamkiewicz-Drożyńska E; Bączek T Talanta; 2016 Apr; 150():331-9. PubMed ID: 26838416 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]