179 related articles for article (PubMed ID: 10745446)
1. Successful treatment of coronary artery perforation during angioplasty using a new membrane-coated stent.
Casella G; Werner F; Klauss V; Mudra H
J Invasive Cardiol; 1999 Oct; 11(10):622-6. PubMed ID: 10745446
[TBL] [Abstract][Full Text] [Related]
2. Use of stent grafts and coils in vessel rupture and perforation.
Yeo KK; Rogers JH; Laird JR
J Interv Cardiol; 2008 Feb; 21(1):86-99. PubMed ID: 18254790
[TBL] [Abstract][Full Text] [Related]
3. Treatment of recurrent coronary rupture by implantation of three coronary stent-grafts.
Veselka J; Tesar D; Honek T; Burkert J
Int J Cardiovasc Intervent; 2003; 5(2):88-91. PubMed ID: 12745866
[TBL] [Abstract][Full Text] [Related]
4. Use of a novel pericardial covered stent to seal an iatrogenic coronary perforation.
Jokhi PP; McKenzie DB; O'Kane P
J Invasive Cardiol; 2009 Oct; 21(10):E187-90. PubMed ID: 19805849
[TBL] [Abstract][Full Text] [Related]
5. Emergency repair of coronary perforation following percutaneous transluminal coronary angioplasty failure: A high-risk choice?
Simon C; Roscitano A; Capuano F; Bianchini R; Tonelli E; Sinatra R
J Cardiovasc Med (Hagerstown); 2006 May; 7(5):365-7. PubMed ID: 16645417
[TBL] [Abstract][Full Text] [Related]
6. Occlusion of the saphenous vein graft at the site of polytetrafluoroethylene membrane-covered stent implantation: was it late thrombosis?
Toutouzas K; Takagi T; Colombo A
J Invasive Cardiol; 2003 Dec; 15(12):722-4. PubMed ID: 14660828
[No Abstract] [Full Text] [Related]
7. Percutaneous treatment of a giant coronary aneurysm using a Symbiot stent.
Roy P; Ajani AE; Warren R
Cardiovasc Revasc Med; 2005; 6(2):73-4. PubMed ID: 16263363
[TBL] [Abstract][Full Text] [Related]
8. Successful sealing of an angioplasty-related saphenous vein graft rupture with a PTFE-covered stent.
Hernandez-Antolin RA; Banuelos C; Alfonso F; Escaned J; Fernandez-Ortiz A; Sabaté M; Amador E; Macaya C
J Invasive Cardiol; 2000 Nov; 12(11):589-93. PubMed ID: 11060573
[TBL] [Abstract][Full Text] [Related]
9. Successful treatment of coronary artery perforation during angioplasty using autologous vein graft-coated stent.
Chae JK; Park SW; Kim YH; Hong MK; Park SJ
Eur Heart J; 1997 Jun; 18(6):1030-2. PubMed ID: 9183598
[TBL] [Abstract][Full Text] [Related]
10. Large pseudoaneurysm after left main trunk stenting sealed by polytetrafluorethylene-covered stent.
Nameki M; Ishiwata S; Momomura S
Catheter Cardiovasc Interv; 2003 Oct; 60(2):233-5. PubMed ID: 14517932
[TBL] [Abstract][Full Text] [Related]
11. Percutaneous saphenectomy: a potentially dreadful complication of cutting balloon angioplasty in saphenous vein grafts.
Tassanawiwat W; Biondi-Zoccai GG; Sangiorgi G; Iakovou I; Tsagalou E; Melzi G; Ge L; Morici N; Corvaja N; Colombo A
Int J Cardiol; 2006 Jan; 106(3):418-9. PubMed ID: 16337059
[TBL] [Abstract][Full Text] [Related]
12. [Cardiac perforation complicated by cardiac tamponade and sealed with metallic coils].
Martí V; Castaño C; Guiteras P; Vallés E; Domínguez de Rozas JM; Augé JM
Rev Esp Cardiol; 2004 Oct; 57(10):990-2. PubMed ID: 15469797
[TBL] [Abstract][Full Text] [Related]
13. Coronary perforation and tamponade during thrombectomy and treatment with PTFE coated stent and autotransfusion: a case report.
Bilge AK; Nişanci Y; Ozben B; Yilmaz E; Umman B
Anadolu Kardiyol Derg; 2003 Jun; 3(2):174-6. PubMed ID: 12826515
[No Abstract] [Full Text] [Related]
14. Treatment of coronary artery perforations complicating percutaneous coronary intervention with a polytetrafluoroethylene-covered stent graft.
Lansky AJ; Yang YM; Khan Y; Costa RA; Pietras C; Tsuchiya Y; Cristea E; Collins M; Mehran R; Dangas GD; Moses JW; Leon MB; Stone GW
Am J Cardiol; 2006 Aug; 98(3):370-4. PubMed ID: 16860026
[TBL] [Abstract][Full Text] [Related]
15. Conservative approach for perforation and early pseudoaneurysm of left anterior descending artery during overlapped stenting.
Alidoosti M; Soleimani A; Abbasi A
J Invasive Cardiol; 2009 May; 21(5):E81-3. PubMed ID: 19411731
[TBL] [Abstract][Full Text] [Related]
16. The driver stent for coronary bifurcations: a clinical case and bench testing of provisional "culotte" side-branch stenting.
Ormiston JA; Currie E; Panther MJ; Webster MW; O'Shaughnessy B
J Invasive Cardiol; 2004 Feb; 16(2):1-3; quiz 4. PubMed ID: 14986621
[No Abstract] [Full Text] [Related]
17. Emergency polytetrafluoroethylene-covered stent implantation to treat right coronary artery perforation during percutaneous coronary intervention.
Yorgun H; Canpolat U; Aytemir K; Oto A
Cardiol J; 2012; 19(6):639-42. PubMed ID: 23224929
[TBL] [Abstract][Full Text] [Related]
18. Treatment of a giant coronary aneurysm with a novel technique: scaffolding (tunnel) stenting to support PTFE-covered stents: insights from intravascular ultrasound.
López-Meneses M; Alfonso F; Fernández-Ortíz A; Escaned J; Flores A; García P; Arias J; Sabaté M; Hernández R; Bañuelos C; Macaya C
J Invasive Cardiol; 2002 May; 14(5):273-6. PubMed ID: 11983951
[TBL] [Abstract][Full Text] [Related]
19. An unusual mid term complication of coronary rupture.
Bonello L; Paule P; Quilici J; Lambert M; Fourcade L; Bonnet JL
Int J Cardiol; 2005 Sep; 104(1):119-21. PubMed ID: 16014314
[TBL] [Abstract][Full Text] [Related]
20. The use of a JOMED PTFE-covered stent graft to treat a thrombotic-aneurysmatic native coronary artery following myocardial infarction.
Kornowksi R
Int J Cardiovasc Intervent; 2004; 6(2):91. PubMed ID: 15385210
[No Abstract] [Full Text] [Related]
[Next] [New Search]