BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

428 related articles for article (PubMed ID: 10745499)

  • 1. Stent design favorably influences the vascular response in normal porcine coronary arteries.
    Carter AJ; Scott D; Rahdert D; Bailey L; De Vries J ; Ayerdi K; Turnlund T; Jones R; Virmani R; Fischell TA
    J Invasive Cardiol; 1999 Mar; 11(3):127-34. PubMed ID: 10745499
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Progressive vascular remodeling and reduced neointimal formation after placement of a thermoelastic self-expanding nitinol stent in an experimental model.
    Carter AJ; Scott D; Laird JR; Bailey L; Kovach JA; Hoopes TG; Pierce K; Heath K; Hess K; Farb A; Virmani R
    Cathet Cardiovasc Diagn; 1998 Jun; 44(2):193-201. PubMed ID: 9637443
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Coronary stenting with a novel stainless steel balloon-expandable stent: determinants of neointimal formation and changes in arterial geometry after placement in an atherosclerotic model.
    Carter AJ; Laird JR; Kufs WM; Bailey L; Hoopes TG; Reeves T; Farb A; Virmani R
    J Am Coll Cardiol; 1996 Apr; 27(5):1270-7. PubMed ID: 8609355
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Experimental evaluation of a short transitional edge protection balloon for intracoronary stent deployment.
    Carter AJ; Lee DP; Suzuki T; Bailey L; Lansky A; Jones R; Virmani R
    Catheter Cardiovasc Interv; 2000 Sep; 51(1):112-9. PubMed ID: 10973033
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Experimental Results with the Multi-Linkª Stent in a Porcine Model.
    Thomas WJ; Laird JR; Bailey L; Hoopes TG; Hillhouse R; Scott D; Jones R; Virmani R; Carter AJ
    J Invasive Cardiol; 1997 Sep; 9(7):453-460. PubMed ID: 10762942
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparison of the vascular responses to balloon-expandable stenting in the coronary and peripheral circulations: long-term results in an animal model using the TriMaxx stent.
    Dubé H; Clifford AG; Barry CM; Schwarten DE; Schwartz LB
    J Vasc Surg; 2007 Apr; 45(4):821-7. PubMed ID: 17398392
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A comparison of four stent designs on arterial injury, cellular proliferation, neointima formation, and arterial dimensions in an experimental porcine model.
    Taylor AJ; Gorman PD; Kenwood B; Hudak C; Tashko G; Virmani R
    Catheter Cardiovasc Interv; 2001 Jul; 53(3):420-5. PubMed ID: 11458427
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Segmental vessel wall shear stress and neointimal formation after sirolimus-eluting stent implantation: physiological insights in a porcine coronary model.
    Carter AJ; Wei W; Gibson L; Collingwood R; Tio F; Dooley J; Kopia GA
    Cardiovasc Revasc Med; 2005; 6(2):58-64. PubMed ID: 16263360
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Restenosis following placement of an intracoronary heparin treated tantulum stent in the hyperlipidemic miniature swine model.
    Jenkins JS; Webel R; Laughlin MH; Rowland SM; Yoklavich MF; Amann JF; Branson K; Myers PR
    J Invasive Cardiol; 1995; 7(6):173-82. PubMed ID: 10155102
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The effects of uncontrolled hyperglycemia on thrombosis and formation of neointima after coronary stent placement in a novel diabetic porcine model of restenosis.
    Carter AJ; Bailey L; Devries J; Hubbard B
    Coron Artery Dis; 2000 Sep; 11(6):473-9. PubMed ID: 10966133
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Angiographic and histological results following implantation of a novel stent-on-a-wire in the animal model.
    Diletti R; Garcia-Garcia HM; van Geuns RJ; Farooq V; Bailey L; Rousselle S; Kopia G; Easterbrook W; Pomeranz M; Serruys PW
    EuroIntervention; 2012 Jul; 8(3):390-9. PubMed ID: 22377624
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Accuracy of optical coherence tomography in the evaluation of neointimal coverage after stent implantation.
    Murata A; Wallace-Bradley D; Tellez A; Alviar C; Aboodi M; Sheehy A; Coleman L; Perkins L; Nakazawa G; Mintz G; Kaluza GL; Virmani R; Granada JF
    JACC Cardiovasc Imaging; 2010 Jan; 3(1):76-84. PubMed ID: 20129535
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Stent-based delivery of ABT-578 via a phosphorylcholine surface coating reduces neointimal formation in the porcine coronary model.
    Collingwood R; Gibson L; Sedlik S; Virmani R; Carter AJ
    Catheter Cardiovasc Interv; 2005 Jun; 65(2):227-32. PubMed ID: 15900559
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Effect of endovascular stent strut geometry on vascular injury, myointimal hyperplasia, and restenosis.
    Sullivan TM; Ainsworth SD; Langan EM; Taylor S; Snyder B; Cull D; Youkey J; Laberge M
    J Vasc Surg; 2002 Jul; 36(1):143-9. PubMed ID: 12096272
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A third generation ultra-thin strut cobalt chromium stent: histopathological evaluation in porcine coronary arteries.
    Jabara R; Geva S; Ribeiro HB; Chen JP; Hou D; Li J; King SB; Chronos N; Robinson KA
    EuroIntervention; 2009 Nov; 5(5):619-26. PubMed ID: 20142184
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Neointimal hyperplasia and late pathologic remodeling in a porcine coronary stent model.
    De Scheerder I ; Wang K; Zhou XR; Verbeken E; Ping QB; Yanming H; Jianhua H; Szilard M; Van de Werf F
    J Invasive Cardiol; 1999 Jan; 11(1):9-12. PubMed ID: 10745430
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Restenosis is not associated with stent length in a pig model of coronary stent implantation.
    Koutouzis M; Papalois A; Kyrzopoulos S; Dafnomili P; Kyriakides ZS
    Cardiol J; 2008; 15(5):458-62. PubMed ID: 18810722
    [TBL] [Abstract][Full Text] [Related]  

  • 18. In vivo assessment of stent recoil in normal porcine arteries: evaluation of contemporary stent designs.
    Garcia LA; Hosley SE; Baim DS; Carrozza JP
    Catheter Cardiovasc Interv; 2001 Jun; 53(2):277-80. PubMed ID: 11387621
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Tissue proliferation within and surrounding Palmaz-Schatz stents is dependent on the aggressiveness of stent implantation technique.
    Hoffmann R; Mintz GS; Mehran R; Kent KM; Pichard AD; Satler LF; Leon MB
    Am J Cardiol; 1999 Apr; 83(8):1170-4. PubMed ID: 10215278
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Long term impact of balloon post-dilatation on neointimal formation: an experimental comparative study between second-generation self-expanding versus balloon-expandable stent technologies.
    Aboodi MS; Milewski K; Tellez A; Cheng Y; Yi GH; Kaluza GL; Granada JF
    Catheter Cardiovasc Interv; 2014 Feb; 83(3):397-404. PubMed ID: 25295313
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 22.