BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

94 related articles for article (PubMed ID: 10752435)

  • 21. A comparison of the shaping abilities of 4 nickel-titanium rotary instruments in simulated root canals.
    Yun HH; Kim SK
    Oral Surg Oral Med Oral Pathol Oral Radiol Endod; 2003 Feb; 95(2):228-33. PubMed ID: 12582365
    [TBL] [Abstract][Full Text] [Related]  

  • 22. The influence of various automated devices on the shaping ability of Mtwo rotary nickel-titanium instruments.
    Bürklein S; Schäfer E
    Int Endod J; 2006 Dec; 39(12):945-51. PubMed ID: 17107539
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Effect of rotational speed on nickel-titanium file distortion.
    Gabel WP; Hoen M; Steiman HR; Pink FE; Dietz R
    J Endod; 1999 Nov; 25(11):752-4. PubMed ID: 10726544
    [TBL] [Abstract][Full Text] [Related]  

  • 24. The K3 rotary nickel-titanium file system.
    Mounce RE
    Dent Clin North Am; 2004 Jan; 48(1):137-57. PubMed ID: 15066511
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Comparative investigation of two rotary nickel-titanium instruments: ProTaper versus RaCe. Part 2. Cleaning effectiveness and shaping ability in severely curved root canals of extracted teeth.
    Schäfer E; Vlassis M
    Int Endod J; 2004 Apr; 37(4):239-48. PubMed ID: 15056350
    [TBL] [Abstract][Full Text] [Related]  

  • 26. The effectiveness of three instrumentation techniques on the elimination of Enterococcus faecalis from a root canal: an in vitro study.
    Colak M; Evcil S; Bayindir YZ; Yigit N
    J Contemp Dent Pract; 2005 Feb; 6(1):94-106. PubMed ID: 15719081
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Simplifying endodontics with endosequence rotary instrumentation.
    Kurtzman GM
    J Calif Dent Assoc; 2007 Sep; 35(9):625-8. PubMed ID: 17993214
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Undergraduate teaching and clinical use of rotary nickel-titanium endodontic instruments: a survey of French dental schools.
    Arbab-Chirani R; Vulcain JM
    Int Endod J; 2004 May; 37(5):320-4. PubMed ID: 15086753
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Influence of rotational speed on the cyclic fatigue of rotary nickel-titanium endodontic instruments.
    Lopes HP; Ferreira AA; Elias CN; Moreira EJ; de Oliveira JC; Siqueira JF
    J Endod; 2009 Jul; 35(7):1013-6. PubMed ID: 19567325
    [TBL] [Abstract][Full Text] [Related]  

  • 30. The feel of steel, Part 1.
    Rozen J
    Dent Today; 1998 Apr; 17(4):58-60, 62-5. PubMed ID: 9791215
    [No Abstract]   [Full Text] [Related]  

  • 31. Taking the mystery out of endodontics, Part 4: Cleaning and shaping, pure and simple.
    Weathers AK; Wahl P
    Dent Today; 1998 Oct; 17(10):94, 96-7. PubMed ID: 10752436
    [No Abstract]   [Full Text] [Related]  

  • 32. Predictable endodontic success. The apical control zone.
    Serota KS; Nahmias Y; Barnett F; Brock M; Senia ES
    Dent Today; 2003 May; 22(5):90-7. PubMed ID: 12778678
    [No Abstract]   [Full Text] [Related]  

  • 33. The predefined endodontic preparation: instrument and technique updates for the greater taper system.
    Buchanan LS
    Dent Today; 2001 Jan; 20(1):56-60, 62-5. PubMed ID: 12524888
    [No Abstract]   [Full Text] [Related]  

  • 34. Comparative analysis of torsional and bending stresses in two mathematical models of nickel-titanium rotary instruments: ProTaper versus ProFile.
    Berutti E; Chiandussi G; Gaviglio I; Ibba A
    J Endod; 2003 Jan; 29(1):15-9. PubMed ID: 12540212
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Torque during canal instrumentation using rotary nickel-titanium files.
    Sattapan B; Palamara JE; Messer HH
    J Endod; 2000 Mar; 26(3):156-60. PubMed ID: 11199710
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Comparison of forces generated during root canal shaping and residual stresses of three nickel-titanium rotary files by using a three-dimensional finite-element analysis.
    Kim HC; Cheung GS; Lee CJ; Kim BM; Park JK; Kang SI
    J Endod; 2008 Jun; 34(6):743-7. PubMed ID: 18498904
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Best of both worlds: stainless steel and nickel titanium.
    Klein P
    Dent Today; 1999 Jul; 18(7):66-9. PubMed ID: 10786173
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Advancements in the design of endodontic instruments for root canal preparation.
    Machtou P; Ruddle CJ
    Alpha Omegan; 2004 Dec; 97(4):8-15. PubMed ID: 15651579
    [No Abstract]   [Full Text] [Related]  

  • 39. Nickel-titanium rotary instrument fracture: a clinical practice assessment.
    Di Fiore PM; Genov KA; Komaroff E; Li Y; Lin L
    Int Endod J; 2006 Sep; 39(9):700-8. PubMed ID: 16916359
    [TBL] [Abstract][Full Text] [Related]  

  • 40. The quality of apical canal preparation using hand and rotary instruments with specific criteria for enlargement based on initial apical file size.
    Tan BT; Messer HH
    J Endod; 2002 Sep; 28(9):658-64. PubMed ID: 12236311
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 5.