These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
159 related articles for article (PubMed ID: 10752812)
1. Safety, efficacy, and cost-effectiveness of mechanical ventilation with humidifying filters changed every 48 hours: a prospective, randomized study. Markowicz P; Ricard JD; Dreyfuss D; Mier L; Brun P; Coste F; Boussougant Y; Djedaïni K Crit Care Med; 2000 Mar; 28(3):665-71. PubMed ID: 10752812 [TBL] [Abstract][Full Text] [Related]
2. Long-term mechanical ventilation with hygroscopic heat and moisture exchangers used for 48 hours: a prospective clinical, hygrometric, and bacteriologic study. Boyer A; Thiéry G; Lasry S; Pigné E; Salah A; de Lassence A; Dreyfuss D; Ricard JD Crit Care Med; 2003 Mar; 31(3):823-9. PubMed ID: 12626991 [TBL] [Abstract][Full Text] [Related]
3. Efficiency and safety of mechanical ventilation with a heat and moisture exchanger changed only once a week. Ricard JD; Le Mière E; Markowicz P; Lasry S; Saumon G; Djedaïni K; Coste F; Dreyfuss D Am J Respir Crit Care Med; 2000 Jan; 161(1):104-9. PubMed ID: 10619805 [TBL] [Abstract][Full Text] [Related]
4. Changing heat and moisture exchangers after 96 hours rather than after 24 hours: a clinical and microbiological evaluation. Thomachot L; Boisson C; Arnaud S; Michelet P; Cambon S; Martin C Crit Care Med; 2000 Mar; 28(3):714-20. PubMed ID: 10752820 [TBL] [Abstract][Full Text] [Related]
5. Bedside evaluation of efficient airway humidification during mechanical ventilation of the critically ill. Ricard JD; Markowicz P; Djedaini K; Mier L; Coste F; Dreyfuss D Chest; 1999 Jun; 115(6):1646-52. PubMed ID: 10378563 [TBL] [Abstract][Full Text] [Related]
6. Heat and moisture exchangers in mechanically ventilated intensive care unit patients: a plea for an independent assessment of their performance. Thiéry G; Boyer A; Pigné E; Salah A; De Lassence A; Dreyfuss D; Ricard JD Crit Care Med; 2003 Mar; 31(3):699-704. PubMed ID: 12626972 [TBL] [Abstract][Full Text] [Related]
7. Changing a hydrophobic heat and moisture exchanger after 48 hours rather than 24 hours: a clinical and microbiological evaluation. Boisson C; Viviand X; Arnaud S; Thomachot L; Miliani Y; Martin C Intensive Care Med; 1999 Nov; 25(11):1237-43. PubMed ID: 10654207 [TBL] [Abstract][Full Text] [Related]
8. Prolonged use of heat and moisture exchangers does not affect device efficiency or frequency rate of nosocomial pneumonia. Davis K; Evans SL; Campbell RS; Johannigman JA; Luchette FA; Porembka DT; Branson RD Crit Care Med; 2000 May; 28(5):1412-8. PubMed ID: 10834688 [TBL] [Abstract][Full Text] [Related]
9. Do the components of heat and moisture exchanger filters affect their humidifying efficacy and the incidence of nosocomial pneumonia? Thomachot L; Vialet R; Arnaud S; Barberon B; Michel-Nguyen A; Martin C Crit Care Med; 1999 May; 27(5):923-8. PubMed ID: 10362414 [TBL] [Abstract][Full Text] [Related]
10. Efficacy of heat and moisture exchangers after changing every 48 hours rather than 24 hours. Thomachot L; Vialet R; Viguier JM; Sidier B; Roulier P; Martin C Crit Care Med; 1998 Mar; 26(3):477-81. PubMed ID: 9504575 [TBL] [Abstract][Full Text] [Related]
11. Influence of ambient temperature and minute ventilation on passive and active heat and moisture exchangers. Lellouche F; Qader S; Taillé S; Lyazidi A; Brochard L Respir Care; 2014 May; 59(5):637-43. PubMed ID: 24106325 [TBL] [Abstract][Full Text] [Related]
12. Comparing two heat and moisture exchangers, one hydrophobic and one hygroscopic, on humidifying efficacy and the rate of nosocomial pneumonia. Thomachot L; Viviand X; Arnaud S; Boisson C; Martin CD Chest; 1998 Nov; 114(5):1383-9. PubMed ID: 9824019 [TBL] [Abstract][Full Text] [Related]
13. Randomized clinical trial of extended use of a hydrophobic condenser humidifier: 1 vs. 7 days. Thomachot L; Leone M; Razzouk K; Antonini F; Vialet R; Martin C Crit Care Med; 2002 Jan; 30(1):232-7. PubMed ID: 11902268 [TBL] [Abstract][Full Text] [Related]
14. Preservation of humidity and heat of respiratory gases in patients with a minute ventilation greater than 10 L/min. Martin C; Papazian L; Perrin G; Saux P; Gouin F Crit Care Med; 1994 Nov; 22(11):1871-6. PubMed ID: 7956294 [TBL] [Abstract][Full Text] [Related]
15. Comparing two heat and moisture exchangers with one vaporizing humidifier in patients with minute ventilation greater than 10 L/min. Martin C; Thomachot L; Quinio B; Viviand X; Albanese J Chest; 1995 May; 107(5):1411-5. PubMed ID: 7750340 [TBL] [Abstract][Full Text] [Related]
16. In vitro and in vivo evaluation of a new active heat moisture exchanger. Chiumello D; Pelosi P; Park G; Candiani A; Bottino N; Storelli E; Severgnini P; D'Onofrio D; Gattinoni L; Chiaranda M Crit Care; 2004 Oct; 8(5):R281-8. PubMed ID: 15469569 [TBL] [Abstract][Full Text] [Related]
17. Changing heat and moisture exchangers every 48 hours rather than 24 hours does not affect their efficacy and the incidence of nosocomial pneumonia. Djedaini K; Billiard M; Mier L; Le Bourdelles G; Brun P; Markowicz P; Estagnasie P; Coste F; Boussougant Y; Dreyfuss D Am J Respir Crit Care Med; 1995 Nov; 152(5 Pt 1):1562-9. PubMed ID: 7582295 [TBL] [Abstract][Full Text] [Related]
18. Bacterial and viral removal efficiency, heat and moisture exchange properties of four filtration devices. Vanderbroucke-Grauls CM; Teeuw KB; Ballemans K; Lavooij C; Cornelisse PB; Verhoef J J Hosp Infect; 1995 Jan; 29(1):45-56. PubMed ID: 7738339 [TBL] [Abstract][Full Text] [Related]
19. Effects of a heat and moisture exchanger and a heated humidifier on respiratory mucus in patients undergoing mechanical ventilation. Nakagawa NK; Macchione M; Petrolino HM; Guimarães ET; King M; Saldiva PH; Lorenzi-Filho G Crit Care Med; 2000 Feb; 28(2):312-7. PubMed ID: 10708159 [TBL] [Abstract][Full Text] [Related]