BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

114 related articles for article (PubMed ID: 10761769)

  • 1. A robotic system for blood sampling.
    Zivanovic A; Davies BL
    IEEE Trans Inf Technol Biomed; 2000 Mar; 4(1):8-14. PubMed ID: 10761769
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Research of the master-slave robot surgical system with the function of force feedback.
    Shi Y; Zhou C; Xie L; Chen Y; Jiang J; Zhang Z; Deng Z
    Int J Med Robot; 2017 Dec; 13(4):. PubMed ID: 28513095
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Experimental evaluation of magnified haptic feedback for robot-assisted needle insertion and palpation.
    Meli L; Pacchierotti C; Prattichizzo D
    Int J Med Robot; 2017 Dec; 13(4):. PubMed ID: 28218455
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Prototype tactile feedback system for examination by skin touch.
    Lee O; Lee K; Oh C; Kim K; Kim M
    Skin Res Technol; 2014 Aug; 20(3):307-14. PubMed ID: 24267404
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Hippocrate: a safe robot arm for medical applications with force feedback.
    Pierrot F; Dombre E; Dégoulange E; Urbain L; Caron P; Boudet S; Gariépy J; Mégnien JL
    Med Image Anal; 1999 Sep; 3(3):285-300. PubMed ID: 10710297
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Coaxial needle insertion assistant with enhanced force feedback.
    De Lorenzo D; Koseki Y; De Momi E; Chinzei K; Okamura AM
    IEEE Trans Biomed Eng; 2013 Feb; 60(2):379-89. PubMed ID: 23193302
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Robot-assisted ultrasound imaging: overview and development of a parallel telerobotic system.
    Monfaredi R; Wilson E; Azizi Koutenaei B; Labrecque B; Leroy K; Goldie J; Louis E; Swerdlow D; Cleary K
    Minim Invasive Ther Allied Technol; 2015 Feb; 24(1):54-62. PubMed ID: 25540071
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Three-dimensional ultrasound image-guided robotic system for accurate microwave coagulation of malignant liver tumours.
    Xu J; Jia ZZ; Song ZJ; Yang XD; Chen K; Liang P
    Int J Med Robot; 2010 Sep; 6(3):256-68. PubMed ID: 20564429
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Design of a haptic device with grasp and push-pull force feedback for a master-slave surgical robot.
    Hu Z; Yoon CH; Park SB; Jo YH
    Int J Comput Assist Radiol Surg; 2016 Jul; 11(7):1361-9. PubMed ID: 26646414
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Computer guidance system for single-incision bimanual robotic surgery.
    Carbone M; Turini G; Petroni G; Niccolini M; Menciassi A; Ferrari M; Mosca F; Ferrari V
    Comput Aided Surg; 2012; 17(4):161-71. PubMed ID: 22687053
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Robot-assisted prostate brachytherapy.
    Yu Y; Podder T; Zhang Y; Ng WS; Misic V; Sherman J; Fu L; Fuller D; Messing E; Rubens D; Strang J; Brasacchio R
    Med Image Comput Comput Assist Interv; 2006; 9(Pt 1):41-9. PubMed ID: 17354872
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Clarification of the characteristics of needle-tip movement during vacuum venipuncture to improve safety.
    Fujii C
    Vasc Health Risk Manag; 2013; 9():381-90. PubMed ID: 23901281
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Augmented reality and haptic interfaces for robot-assisted surgery.
    Yamamoto T; Abolhassani N; Jung S; Okamura AM; Judkins TN
    Int J Med Robot; 2012 Mar; 8(1):45-56. PubMed ID: 22069247
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Effects of realistic force feedback in a robotic assisted minimally invasive surgery system.
    Moradi Dalvand M; Shirinzadeh B; Nahavandi S; Smith J
    Minim Invasive Ther Allied Technol; 2014 Jun; 23(3):127-35. PubMed ID: 24328984
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Schemes for the identification of tissue types and boundaries at the tool point for surgical needles.
    Brett PN; Harrison AJ; Thomas TA
    IEEE Trans Inf Technol Biomed; 2000 Mar; 4(1):30-6. PubMed ID: 10761771
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A novel automated discontinuous venous blood monitoring system for ex vivo glucose determination in humans.
    Schaller R; Feichtner F; Köhler H; Bodenlenz M; Plank J; Wutte A; Mader JK; Ellmerer M; Hellmich R; Wedig H; Hainisch R; Pieber TR; Schaupp L
    Biosens Bioelectron; 2009 Mar; 24(7):2239-45. PubMed ID: 19135351
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Present and future developments of the virtual surgery and tele-virtual surgery system].
    Suzuki S; Suzuki N; Hattori A; Hayashibe M; Otake Y; Kobayashi S; Hashizume M
    Nihon Rinsho; 2004 Apr; 62(4):815-23. PubMed ID: 15106354
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A venipuncture robot with decoupled position and attitude guided by near-infrared vision and force feedback.
    He T; Guo C; Liu H; Jiang L
    Int J Med Robot; 2023 Aug; 19(4):e2512. PubMed ID: 36809654
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A robotic catheter system with real-time force feedback and monitor.
    Xiao N; Guo J; Guo S; Tamiya T
    Australas Phys Eng Sci Med; 2012 Sep; 35(3):283-9. PubMed ID: 22763489
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Autonomous function of wheelchair-mounted robotic manipulators to perform daily activities.
    Chung CS; Wang H; Cooper RA
    IEEE Int Conf Rehabil Robot; 2013 Jun; 2013():6650378. PubMed ID: 24187197
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]