161 related articles for article (PubMed ID: 10783273)
1. Remote tuning of NMR probe circuits.
Kodibagkar VD; Conradi MS
J Magn Reson; 2000 May; 144(1):53-7. PubMed ID: 10783273
[TBL] [Abstract][Full Text] [Related]
2. An easily constructed, tuning free, ultra-broadband probe for NMR.
Murphree D; Cahn SB; Rahmlow D; Demille D
J Magn Reson; 2007 Sep; 188(1):160-7. PubMed ID: 17686642
[TBL] [Abstract][Full Text] [Related]
3. Low temperature probe for dynamic nuclear polarization and multiple-pulse solid-state NMR.
Cho H; Baugh J; Ryan CA; Cory DG; Ramanathan C
J Magn Reson; 2007 Aug; 187(2):242-50. PubMed ID: 17524687
[TBL] [Abstract][Full Text] [Related]
4. RF probe recovery time reduction with a novel active ringing suppression circuit.
Peshkovsky AS; Forguez J; Cerioni L; Pusiol DJ
J Magn Reson; 2005 Nov; 177(1):67-73. PubMed ID: 16111906
[TBL] [Abstract][Full Text] [Related]
5. A high-pressure, high-resolution NMR probe for experiments at 500 MHz.
Ballard L; Yu A; Reiner C; Jonas J
J Magn Reson; 1998 Jul; 133(1):190-3. PubMed ID: 9654485
[TBL] [Abstract][Full Text] [Related]
6. Multiple-sample probe for solid-state NMR studies of pharmaceuticals.
Nelson BN; Schieber LJ; Barich DH; Lubach JW; Offerdahl TJ; Lewis DH; Heinrich JP; Munson EJ
Solid State Nucl Magn Reson; 2006 Feb; 29(1-3):204-13. PubMed ID: 16246531
[TBL] [Abstract][Full Text] [Related]
7. Design of a high-power NMR probe for low-temperature studies.
Damyanovich AZ; Peternelj J; Pintar MM
J Magn Reson; 2000 May; 144(1):1-5. PubMed ID: 10783267
[TBL] [Abstract][Full Text] [Related]
8. Low-frequency NMR with a non-resonant circuit.
Hopper T; Mandal S; Cory D; Hürlimann M; Song YQ
J Magn Reson; 2011 May; 210(1):69-74. PubMed ID: 21382732
[TBL] [Abstract][Full Text] [Related]
9. Using low-E resonators to reduce RF heating in biological samples for static solid-state NMR up to 900 MHz.
Gor'kov PL; Chekmenev EY; Li C; Cotten M; Buffy JJ; Traaseth NJ; Veglia G; Brey WW
J Magn Reson; 2007 Mar; 185(1):77-93. PubMed ID: 17174130
[TBL] [Abstract][Full Text] [Related]
10. Fast recovery, high sensitivity NMR probe and preamplifier for low frequencies.
Hoult DI
Rev Sci Instrum; 1979 Feb; 50(2):193. PubMed ID: 18699468
[TBL] [Abstract][Full Text] [Related]
11. Small crystals and small coils in variable-temperature single-crystal NMR.
Vosegaard T; Daugaard P; Hald E; Jakobsen HJ
J Magn Reson; 2000 Feb; 142(2):379-81. PubMed ID: 10648158
[TBL] [Abstract][Full Text] [Related]
12. The design and use of a dual-frequency surface coil providing proton images for improved localization in 31P spectroscopy of small lesions.
Leach MO; Hind A; Sauter R; Requardt H; Weber H
Med Phys; 1986; 13(4):510-3. PubMed ID: 3736508
[TBL] [Abstract][Full Text] [Related]
13. Cross polarization, radio frequency field homogeneity, and circuit balancing in high field solid state NMR probes.
Paulson EK; Martin RW; Zilm KW
J Magn Reson; 2004 Dec; 171(2):314-23. PubMed ID: 15546758
[TBL] [Abstract][Full Text] [Related]
14. 33S nuclear magnetic resonance spectroscopy of biological samples obtained with a laboratory model 33S cryogenic probe.
Hobo F; Takahashi M; Saito Y; Sato N; Takao T; Koshiba S; Maeda H
Rev Sci Instrum; 2010 May; 81(5):054302. PubMed ID: 20515157
[TBL] [Abstract][Full Text] [Related]
15. Low-E probe for (19)F-(1)H NMR of dilute biological solids.
Gor'kov PL; Witter R; Chekmenev EY; Nozirov F; Fu R; Brey WW
J Magn Reson; 2007 Dec; 189(2):182-9. PubMed ID: 17920316
[TBL] [Abstract][Full Text] [Related]
16. Resistive cooling circuits for charged particle traps using crystal resonators.
Kaltenbacher T; Caspers F; Doser M; Kellerbauer A; Pribyl W
Rev Sci Instrum; 2011 Nov; 82(11):114702. PubMed ID: 22128997
[TBL] [Abstract][Full Text] [Related]
17. Design, construction, and validation of a 1-mm triple-resonance high-temperature-superconducting probe for NMR.
Brey WW; Edison AS; Nast RE; Rocca JR; Saha S; Withers RS
J Magn Reson; 2006 Apr; 179(2):290-3. PubMed ID: 16423543
[TBL] [Abstract][Full Text] [Related]
18. Operating nanoliter scale NMR microcoils in a 1 tesla field.
McDowell AF; Adolphi NL
J Magn Reson; 2007 Sep; 188(1):74-82. PubMed ID: 17627856
[TBL] [Abstract][Full Text] [Related]
19. Analyzing and correcting spectrometer temperature sensitivity.
Bowyer PJ; Swanson AG; Morris GA
J Magn Reson; 2001 Oct; 152(2):234-46. PubMed ID: 11567577
[TBL] [Abstract][Full Text] [Related]
20. Estimation and measurement of flat or solenoidal coil inductance for radiofrequency NMR coil design.
Rainey JK; DeVries JS; Sykes BD
J Magn Reson; 2007 Jul; 187(1):27-37. PubMed ID: 17448716
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]