135 related articles for article (PubMed ID: 10791126)
1. External evaluation of LIAISON tumour marker assays on the fully automated chemiluminescent LIAISON immunoassay analyser.
Molina R; Bonfrer J; Banfi G; Bugugnani MJ; Cornu F; Hannemann-Pohl K; Hubl W; Merz O; Bach M; Mack M
Clin Lab; 2000; 46(3-4):169-79. PubMed ID: 10791126
[TBL] [Abstract][Full Text] [Related]
2. Evaluation of the LIAISON thyroid chemiluminescence immunoassays.
Hubl W; Meissner D; Demant T; Becker W; Hörmann R; Bach M; Mack M
Clin Lab; 2000; 46(3-4):181-9. PubMed ID: 10791127
[TBL] [Abstract][Full Text] [Related]
3. LIAISON hCG--an automated chemiluminescent immunoassay for the determination of human chorionic gonadotropin (hCG).
Oed M; Amtmann R; Löwer Y; Schlett R; Mack M
Anticancer Res; 1999; 19(4A):2735-7. PubMed ID: 10470231
[TBL] [Abstract][Full Text] [Related]
4. A multicentre evaluation of the CA 15-3 assay, CA 19-9 assay and CA 125 II assay on the Bayer Immuno 1 System.
Römer M; Haeckel R; Brux B; Sinha P; Raiko I; Krieg M; Stark M; Seidel D; Hübner U; Schmitz G
Eur J Clin Chem Clin Biochem; 1997 Aug; 35(8):637-44. PubMed ID: 9298356
[TBL] [Abstract][Full Text] [Related]
5. LIAISON Ferritin--an automated chemiluminescent immunoassay for the determination of Ferritin.
König B; Oed M; Kunz A; Schlett R; Mack M
Anticancer Res; 1999; 19(4A):2739-41. PubMed ID: 10470232
[TBL] [Abstract][Full Text] [Related]
6. Evaluation of analytical methods and workflow performance of the Architect ci8200 integrated serum/plasma analyzer system.
Hubl W; Zogbaum M; Boyd JC; Savory J; Schubert M; Meyer D; Demant T
Clin Chim Acta; 2005 Jul; 357(1):43-54. PubMed ID: 15963793
[TBL] [Abstract][Full Text] [Related]
7. Analytical performance of Elecsys 2010--a multicentre evaluation.
Stockmann W; Bablok W; Luppa P
Wien Klin Wochenschr; 1998; 110 Suppl 3():10-21. PubMed ID: 9677668
[TBL] [Abstract][Full Text] [Related]
8. Elecsys CEA, PSA and AFP. Clinical results of a multicentre evaluation.
Uhl W; Chan DW; Jones K; Kelley C; Assmann G; von Eckardstein A; Sägers A; Yvert JP; Schneider AM; Torralba A; Fuentes-Arderiu X; Gonzalez de la Presa B; Vives M; Greiling H; Eberle A; Niederau CM; Cremer P; Reiter W; Vogeser M; Neumeier D; Luppa P; Huber U
Wien Klin Wochenschr; 1998; 110 Suppl 3():51-61. PubMed ID: 9677672
[TBL] [Abstract][Full Text] [Related]
9. Evaluation of the DPC IMMULITE random access immunoassay analyser.
Costongs GM; van Oers RJ; Leerkes B; Janson PC
Eur J Clin Chem Clin Biochem; 1995 Nov; 33(11):887-92. PubMed ID: 8620070
[TBL] [Abstract][Full Text] [Related]
10. Liaison free PSA--an automated chemiluminescent immunoassay for the determination of free prostate specific antigen (fPSA).
König B; Ivankovic B; Schleff R; Mack M
Anticancer Res; 1999; 19(4A):2763-5. PubMed ID: 10470237
[TBL] [Abstract][Full Text] [Related]
11. Channel and substrate zone two-dimensional resolution for chemiluminescent multiplex immunoassay.
Fu Z; Yang Z; Tang J; Liu H; Yan F; Ju H
Anal Chem; 2007 Oct; 79(19):7376-82. PubMed ID: 17713968
[TBL] [Abstract][Full Text] [Related]
12. Results of the multicentre evaluation of an electrochemiluminescence immunoassay for HCG on Elecsys 2010.
Ehrhardt V; Assmann G; Bätz O; Bieglmayer C; Müller C; Neumeier D; Roth HJ; Veys A; Yvert JP
Wien Klin Wochenschr; 1998; 110 Suppl 3():61-7. PubMed ID: 9677673
[TBL] [Abstract][Full Text] [Related]
13. Immunoassay of CEA, CA 19-9, CA 125, and CA 15-3 on the automated systems ES 300 and ES 600: methodological evaluation from a multicentre collaborative study.
Zucchelli GC; Pilo A; Jaworek D; Masini S; Chiesa MR
Eur J Clin Chem Clin Biochem; 1992 Dec; 30(12):875-9. PubMed ID: 1489864
[TBL] [Abstract][Full Text] [Related]
14. Multicenter evaluation of a new immunoassay for intact PTH measurement on the Elecsys System 2010 and 1010.
Hermsen D; Franzson L; Hoffmann JP; Isaksson A; Kaufman JM; Leary E; Müller C; Nakatsuka K; Nishizawa Y; Reinauer H; Riesen W; Roth HJ; Steinmüller T; Troch T; Bergmann P
Clin Lab; 2002; 48(3-4):131-41. PubMed ID: 11934215
[TBL] [Abstract][Full Text] [Related]
15. Evaluation of the Abbott automated random, immediate and continuous access immunoassay analyser, the AxSYM.
Costongs GM; van Oers RJ; Leerkens B; Hermans W; Janson PC
Eur J Clin Chem Clin Biochem; 1995 Feb; 33(2):105-11. PubMed ID: 7632821
[TBL] [Abstract][Full Text] [Related]
16. Results from a multicenter evaluation of the 4th generation Elecsys Troponin T assay.
Hermsen D; Apple F; Garcia-Beltràn L; Jaffe A; Karon B; Lewandrowski E; Mühlbacher A; Müller R; Ordóñez J; Pagani F; Panteghini M; Plecko T; Jarausch J
Clin Lab; 2007; 53(1-2):1-9. PubMed ID: 17323819
[TBL] [Abstract][Full Text] [Related]
17. Validation of the first automated chemiluminescence protein-binding assay for the detection of 25-hydroxycalciferol.
Roth HJ; Zahn I; Alkier R; Schmidt H
Clin Lab; 2001; 47(7-8):357-65. PubMed ID: 11499797
[TBL] [Abstract][Full Text] [Related]
18. Evaluation of a new fully automated one-step C-peptide chemiluminescence assay (LIAISON C-Peptid).
Pfützner A; Löbig M; Fortunato A; Forst T
Clin Lab; 2003; 49(5-6):227-32. PubMed ID: 15285178
[TBL] [Abstract][Full Text] [Related]
19. Technical evaluation of three second generation CA 125 assays.
Bonfrer JM; Baan AW; Jansen E; Lentfer D; Kenemans P
Eur J Clin Chem Clin Biochem; 1994 Mar; 32(3):201-7. PubMed ID: 8031969
[TBL] [Abstract][Full Text] [Related]
20. Performance characteristics of IMMULITE TPS: a comparison with TPS IRMA.
Einarsson R; Lei JD; Ullrich A; Van Dalen A
Anticancer Res; 1999; 19(4A):2743-7. PubMed ID: 10470233
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]