These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

135 related articles for article (PubMed ID: 10792284)

  • 21. The ISHAGE guidelines for CD34+ cell determination by flow cytometry. International Society of Hematotherapy and Graft Engineering.
    Sutherland DR; Anderson L; Keeney M; Nayar R; Chin-Yee I
    J Hematother; 1996 Jun; 5(3):213-26. PubMed ID: 8817388
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Enumeration of viable CD34(+) cells by flow cytometry in blood, bone marrow and cord blood: results of a study of the novel BD™ stem cell enumeration kit.
    Dauber K; Becker D; Odendahl M; Seifried E; Bonig H; Tonn T
    Cytotherapy; 2011 Apr; 13(4):449-58. PubMed ID: 21077730
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Consistency of the initial cell acquisition procedure is critical to the standardization of CD34+ cell enumeration by flow cytometry: results of a pairwise analysis of umbilical cord blood units and cryopreserved aliquots.
    Flores AI; McKenna DH; Montalbán MA; De la Cruz J; Wagner JE; Bornstein R
    Transfusion; 2009 Apr; 49(4):636-47. PubMed ID: 19055702
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Comparison of single and dual-platform assay formats for CD34+ haematopoietic progenitor cell enumeration.
    Gratama JW; Braakman E; Kraan J; Lankheet P; Levering WH; Van Den Beemd MW; Van Der Schoot CE; Wijermans P; Preijers F
    Clin Lab Haematol; 1999 Oct; 21(5):337-46. PubMed ID: 10646076
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Single platform flow cytometric absolute CD34+ cell counts based on the ISHAGE guidelines. International Society of Hematotherapy and Graft Engineering.
    Keeney M; Chin-Yee I; Weir K; Popma J; Nayar R; Sutherland DR
    Cytometry; 1998 Apr; 34(2):61-70. PubMed ID: 9579602
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Enumeration of CD34+ hematopoietic progenitor cells in peripheral blood and leukapheresis products by microvolume fluorimetry: a comparison with flow cytometry.
    Read EJ; Kunitake ST; Carter CS; Chau Q; Yu MY; Klein HG
    J Hematother; 1997 Aug; 6(4):291-301. PubMed ID: 9377067
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Evaluation of TruCount absolute-count tubes for determining CD4 and CD8 cell numbers in human immunodeficiency virus-positive adults. Site Investigators and The NIAID DAIDS New Technologies Evaluation Group.
    Schnizlein-Bick CT; Spritzler J; Wilkening CL; Nicholson JK; O'Gorman MR
    Clin Diagn Lab Immunol; 2000 May; 7(3):336-43. PubMed ID: 10799443
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Comparison of interlaboratory variation in absolute T-cell counts by single-platform and optimized dual-platform methods.
    Hultin LE; Chow M; Jamieson BD; O'Gorman MR; Menendez FA; Borowski L; Denny TN; Margolick JB
    Cytometry B Clin Cytom; 2010 May; 78(3):194-200. PubMed ID: 19813263
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Stem cell enumeration by flow cytometry: current concepts and recent developments in CD34+ cell enumeration.
    Keeney M; Sutherland DR
    Cytotherapy; 2000; 2(5):395-402. PubMed ID: 12044236
    [No Abstract]   [Full Text] [Related]  

  • 30. Quality assurance of CD34+ cell estimation in leucapheresis products.
    Lumley MA; McDonald DF; Czarnecka HM; Billingham LJ; Milligan DW
    Bone Marrow Transplant; 1996 Oct; 18(4):791-6. PubMed ID: 8899197
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Comparison of two single-platform ISHAGE-based CD34 enumeration protocols on BD FACSCalibur and FACSCanto flow cytometers.
    Sutherland DR; Nayyar R; Acton E; Giftakis A; Dean S; Mosiman VL
    Cytotherapy; 2009; 11(5):595-605. PubMed ID: 19513900
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Enumeration of CD4(+) T-cells in the peripheral blood of HIV-infected patients: an interlaboratory study of the FACSCount system.
    Lopez A; Caragol I; Candeias J; Villamor N; Echaniz P; Ortuño F; Sempere A; Strauss K; Orfao A
    Cytometry; 1999 Oct; 38(5):231-7. PubMed ID: 10516609
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Direct volumetric flow cytometric quantitation of CD34+ stem and progenitor cells.
    Gutensohn K; Nikolitsis A; Gramatzki M; Spitzer D; Buwitt-Beckmann U; Humpe A
    Transfus Med; 2012 Jun; 22(3):205-10. PubMed ID: 22519551
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Guideline for the flow cytometric enumeration of CD34+ haematopoietic stem cells. Prepared by the CD34+ haematopoietic stem cell working party. General Haematology Task Force of the British Committee for Standards in Haematology.
    Barnett D; Janossy G; Lubenko A; Matutes E; Newland A; Reilly JT
    Clin Lab Haematol; 1999 Oct; 21(5):301-8. PubMed ID: 10646072
    [No Abstract]   [Full Text] [Related]  

  • 35. Assessing agreement between CD34 enumeration by flow cytometry and volumetric analysis.
    Gisselø CG; Roer O; Hoffmann MH; Hansen MB; Taaning E; Johnsen HE
    Bone Marrow Transplant; 2002 Apr; 29(8):699-703. PubMed ID: 12180116
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Current laboratory practices in flow cytometry for the enumeration of CD 4(+) T-lymphocyte subsets.
    Whitby L; Whitby A; Fletcher M; Barnett D
    Cytometry B Clin Cytom; 2015; 88(5):305-11. PubMed ID: 25828263
    [TBL] [Abstract][Full Text] [Related]  

  • 37. The influence of flow cytometric gating strategy and cell preparation procedures on CD34+ cell quantification.
    Yenerel MN; Budak-Alpdogan T; Kalayoglu-Besisik S; Yanasik M; Sargin D
    J Hematother Stem Cell Res; 2000 Feb; 9(1):11-2. PubMed ID: 10738966
    [No Abstract]   [Full Text] [Related]  

  • 38. A single-platform approach using flow cytometry and microbeads to evaluate immune reconstitution in mice after bone marrow transplantation.
    Perruche S; Kleinclauss F; Lienard A; Robinet E; Tiberghien P; Saas P
    J Immunol Methods; 2004 Nov; 294(1-2):53-66. PubMed ID: 15604016
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Optimized flow cytometric analysis of endothelial progenitor cells in peripheral blood.
    Rustemeyer P; Wittkowski W; Jurk K; Koller A
    J Immunoassay Immunochem; 2006; 27(1):77-88. PubMed ID: 16450870
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Flow cytometric lymphocyte subset enumeration: 10 years of external quality assessment in the Benelux countries.
    Levering WH; van Wieringen WN; Kraan J; van Beers WA; Sintnicolaas K; van Rhenen DJ; Gratama JW
    Cytometry B Clin Cytom; 2008 Mar; 74(2):79-90. PubMed ID: 17849485
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.