These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

102 related articles for article (PubMed ID: 10793606)

  • 21. Effects of a new modified, balanced hydroxyethyl starch preparation (Hextend) on measures of coagulation.
    Boldt J; Haisch G; Suttner S; Kumle B; Schellhaass A
    Br J Anaesth; 2002 Nov; 89(5):722-8. PubMed ID: 12393770
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Effect of crystalloid and colloid preloading on uteroplacental and maternal haemodynamic state during spinal anaesthesia for caesarean section.
    Karinen J; Räsänen J; Alahuhta S; Jouppila R; Jouppila P
    Br J Anaesth; 1995 Nov; 75(5):531-5. PubMed ID: 7577275
    [TBL] [Abstract][Full Text] [Related]  

  • 23. The association between thromboelastographic parameters and total estimated blood loss in patients undergoing elective cesarean delivery.
    Butwick A; Ting V; Ralls LA; Harter S; Riley E
    Anesth Analg; 2011 May; 112(5):1041-7. PubMed ID: 21474664
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Artificial colloids impair haemostasis. An in vitro study using thromboelastometry coagulation analysis.
    Niemi TT; Kuitunen AH
    Acta Anaesthesiol Scand; 2005 Mar; 49(3):373-8. PubMed ID: 15752404
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Effects of albumin 5% and artificial colloids on clot formation in small infants.
    Haas T; Preinreich A; Oswald E; Pajk W; Berger J; Kuehbacher G; Innerhofer P
    Anaesthesia; 2007 Oct; 62(10):1000-7. PubMed ID: 17845651
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Effects of plasma dilution on tissue-factor-induced thrombin generation and thromboelastography: partly compensating role of platelets.
    Schols SE; Feijge MA; Lancé MD; Hamulyák K; ten Cate H; Heemskerk JW; van Pampus EC
    Transfusion; 2008 Nov; 48(11):2384-94. PubMed ID: 18673348
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Coagulation assessment in normal pregnancy: thrombelastography with citrated non activated samples.
    Della Rocca G; Dogareschi T; Cecconet T; Buttera S; Spasiano A; Nadbath P; Angelini M; Galluzzo C; Marchesoni D
    Minerva Anestesiol; 2012 Dec; 78(12):1357-64. PubMed ID: 22858878
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Comparative studies on the influence of plasma substitutes on coagulation in vivo.
    Müller KH
    Bibl Haematol; 1969; 33():434-51. PubMed ID: 5384012
    [No Abstract]   [Full Text] [Related]  

  • 29. In vivo investigation into the effects of haemodilution with hydroxyethyl starch (200/0.5) and normal saline on coagulation.
    Ruttmann TG; James MF; Aronson I
    Br J Anaesth; 1998 May; 80(5):612-6. PubMed ID: 9691864
    [TBL] [Abstract][Full Text] [Related]  

  • 30. A randomized trial comparing colloid preload to coload during spinal anesthesia for elective cesarean delivery.
    Siddik-Sayyid SM; Nasr VG; Taha SK; Zbeide RA; Shehade JM; Al Alami AA; Mokadem FH; Abdallah FW; Baraka AS; Aouad MT
    Anesth Analg; 2009 Oct; 109(4):1219-24. PubMed ID: 19641050
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Colloid preload versus coload for spinal anesthesia for cesarean delivery: the effects on maternal cardiac output.
    Teoh WH; Sia AT
    Anesth Analg; 2009 May; 108(5):1592-8. PubMed ID: 19372341
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Effects of colloid pre-loading on thromboelastography during elective intracranial tumor surgery in pediatric patients: hydroxyethyl starch 130/0.4 versus 5% human albumin.
    Peng Y; Du J; Zhao X; Shi X; Wang Y
    BMC Anesthesiol; 2017 Apr; 17(1):62. PubMed ID: 28449710
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Effects on coagulation of intravenous crystalloid or colloid in patients undergoing peripheral vascular surgery.
    Ruttmann TG; James MF; Finlayson J
    Br J Anaesth; 2002 Aug; 89(2):226-30. PubMed ID: 12378657
    [TBL] [Abstract][Full Text] [Related]  

  • 34. The effects of crystalloid and colloid preload on cardiac output in the parturient undergoing planned cesarean delivery under spinal anesthesia: a randomized trial.
    Tamilselvan P; Fernando R; Bray J; Sodhi M; Columb M
    Anesth Analg; 2009 Dec; 109(6):1916-21. PubMed ID: 19923521
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Comparison between two phenylephrine infusion rates with moderate co-loading for the prevention of spinal anaeshtesia-induced hypotension during elective caesarean section.
    Ansari T; Hashem MM; Hassan AA; Gamassy A; Saleh A
    Middle East J Anaesthesiol; 2011 Oct; 21(3):361-6. PubMed ID: 22428490
    [TBL] [Abstract][Full Text] [Related]  

  • 36. The effect of anesthetic techniques on blood coagulability in parturients as measured by thromboelastography.
    Sharma SK; Philip J
    Anesth Analg; 1997 Jul; 85(1):82-6. PubMed ID: 9212127
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Effects of colloid preload on placenta stereology and cord blood S100β protein during cesarean section under spinal anesthesia.
    Peng X; Liu H; Xi L; Wang H; Li R; Shuai B
    Nan Fang Yi Ke Da Xue Xue Bao; 2013 Feb; 33(2):161-5. PubMed ID: 23443764
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Effects on coagulation of balanced (130/0.42) and non-balanced (130/0.4) hydroxyethyl starch or gelatin compared with balanced Ringer's solution: an in vitro study using two different viscoelastic coagulation tests ROTEMTM and SONOCLOTTM.
    Casutt M; Kristoffy A; Schuepfer G; Spahn DR; Konrad C
    Br J Anaesth; 2010 Sep; 105(3):273-81. PubMed ID: 20659913
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Colloids versus crystalloids in the prevention of hypotension induced by spinal anesthesia in elective cesarean section. A systematic review and meta-analysis.
    Ripollés Melchor J; Espinosa Á; Martínez Hurtado E; Casans Francés R; Navarro Pérez R; Abad Gurumeta A; Calvo Vecino JM
    Minerva Anestesiol; 2015 Sep; 81(9):1019-30. PubMed ID: 25501602
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Combined use of crystalloid preload and low dose spinal anesthesia for preventing hypotension in spinal anesthesia for cesarean delivery: a randomized controlled trial.
    Ouerghi S; Bougacha MA; Frikha N; Mestiri T; Ben Ammar MS; Mebazaa MS
    Middle East J Anaesthesiol; 2010 Jun; 20(5):667-72. PubMed ID: 20803854
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.