These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

180 related articles for article (PubMed ID: 10795987)

  • 41. Effect of EEG electrode density on dipole localization accuracy using two realistically shaped skull resistivity models.
    Laarne PH; Tenhunen-Eskelinen ML; Hyttinen JK; Eskola HJ
    Brain Topogr; 2000; 12(4):249-54. PubMed ID: 10912732
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Dipole modeling of epileptic spikes can be accurate or misleading.
    Kobayashi K; Yoshinaga H; Ohtsuka Y; Gotman J
    Epilepsia; 2005 Mar; 46(3):397-408. PubMed ID: 15730537
    [TBL] [Abstract][Full Text] [Related]  

  • 43. A realistic, accurate and fast source modeling approach for the EEG forward problem.
    Miinalainen T; Rezaei A; Us D; Nüßing A; Engwer C; Wolters CH; Pursiainen S
    Neuroimage; 2019 Jan; 184():56-67. PubMed ID: 30165251
    [TBL] [Abstract][Full Text] [Related]  

  • 44. A fast method for forward computation of multiple-shell spherical head models.
    Berg P; Scherg M
    Electroencephalogr Clin Neurophysiol; 1994 Jan; 90(1):58-64. PubMed ID: 7509274
    [TBL] [Abstract][Full Text] [Related]  

  • 45. [Multiple dipole source localization from spatio-temporal EEG data by Quasi-Newton-ICA method].
    Zou L; Zhu S; He B
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2006 Dec; 23(6):1206-12. PubMed ID: 17228710
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Confidence interval of single dipole locations based on EEG data.
    Braun C; Kaiser S; Kincses WE; Elbert T
    Brain Topogr; 1997; 10(1):31-9. PubMed ID: 9358952
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Forward and inverse problems of EEG dipole localization.
    Musha T; Okamoto Y
    Crit Rev Biomed Eng; 1999; 27(3-5):189-239. PubMed ID: 10864280
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Equivalent dipole source imaging of brain electric activity by means of parametric projection filter.
    Hori J; He B
    Ann Biomed Eng; 2001 May; 29(5):436-45. PubMed ID: 11400724
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Influence of anisotropic electrical conductivity in white matter tissue on the EEG/MEG forward and inverse solution. A high-resolution whole head simulation study.
    Güllmar D; Haueisen J; Reichenbach JR
    Neuroimage; 2010 May; 51(1):145-63. PubMed ID: 20156576
    [TBL] [Abstract][Full Text] [Related]  

  • 50. The forward EEG solutions can be computed using artificial neural networks.
    Sun M; Sclabassi RJ
    IEEE Trans Biomed Eng; 2000 Aug; 47(8):1044-50. PubMed ID: 10943052
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Experimental tests of EEG source localization accuracy in realistically shaped head models.
    Cuffin BN; Schomer DL; Ives JR; Blume H
    Clin Neurophysiol; 2001 Dec; 112(12):2288-92. PubMed ID: 11738201
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Artificial neural networks for source localization in the human brain.
    Abeyratne UR; Kinouchi Y; Oki H; Okada J; Shichijo F; Matsumoto K
    Brain Topogr; 1991; 4(1):3-21. PubMed ID: 1764347
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Three-shell head model constructed from scalp geometry for electroencephalogram dipole localization.
    Haque HA; Musha T; Nakajima M
    Front Med Biol Eng; 1999; 9(4):295-304. PubMed ID: 10718667
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Effects of holes on EEG forward solutions using a realistic geometry head model.
    Li J; Wang K; Zhu S; He B
    J Neural Eng; 2007 Sep; 4(3):197-204. PubMed ID: 17873421
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Accuracy of EEG source reconstruction in the presence of brain lesions: modelling errors and surface electrodes' placement.
    Vatta F; Bruno P; Inchingolo P
    Biomed Sci Instrum; 2002; 38():423-8. PubMed ID: 12085644
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Error bounds for EEG and MEG dipole source localization.
    Mosher JC; Spencer ME; Leahy RM; Lewis PS
    Electroencephalogr Clin Neurophysiol; 1993 May; 86(5):303-21. PubMed ID: 7685264
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Numerical calculation of the potential distribution due to dipole sources in a spherical model of the head.
    Abboud S; Eshel Y; Levy S; Rosenfeld M
    Comput Biomed Res; 1994 Dec; 27(6):441-55. PubMed ID: 7895472
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Reduced conductivity dependence method for increase of dipole localization accuracy in the EEG inverse problem.
    Yitembe BR; Crevecoeur G; Van Keer R; Dupre L
    IEEE Trans Biomed Eng; 2011 May; 58(5):1430-40. PubMed ID: 21257364
    [TBL] [Abstract][Full Text] [Related]  

  • 59. MEG versus EEG localization test using implanted sources in the human brain.
    Cohen D; Cuffin BN; Yunokuchi K; Maniewski R; Purcell C; Cosgrove GR; Ives J; Kennedy JG; Schomer DL
    Ann Neurol; 1990 Dec; 28(6):811-7. PubMed ID: 2285267
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Effects of local variations in skull and scalp thickness on EEG's and MEG's.
    Cuffin BN
    IEEE Trans Biomed Eng; 1993 Jan; 40(1):42-8. PubMed ID: 8468075
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.