These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

96 related articles for article (PubMed ID: 1079646)

  • 1. [Clinical use of membrane oxygenators for extended extracroporal circulation].
    Hoffmeister HE; Schorer R; Stunkat R
    Thoraxchir Vask Chir; 1975 Feb; 23(1):49-57. PubMed ID: 1079646
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Use of a membrane oxygenator in extracorporeal circulation in the child. Preliminary conclusions].
    Aubert J; Frigiola A; Pannetier A; Couvélly JP
    Ann Anesthesiol Fr; 1977; 18(1):22-8. PubMed ID: 16540
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Early neurological complications after cardiac surgery under ECC].
    Loisance D; Ledouarin AB; Rotman N; O'Byrne P; Cachera JP; Galey JJ
    Ann Anesthesiol Fr; 1977; 18(1):125-33. PubMed ID: 16537
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Some advantages of the membrane oxygenator for open-heart surgery.
    Wright JS; Fisk GC; Torda TA; Stacey RB; Hicks RG
    J Thorac Cardiovasc Surg; 1975 Jun; 69(6):884-90. PubMed ID: 1134114
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Trends in the choice of anesthesia in heart surgery and in the composition of gas flow in artificial oxygenator ventilation during extracorporal circulation].
    Pagni E; Perna AM; De Angeli D; Noferi D; Poggiali C; Wiechmann V
    Minerva Anestesiol; 1977 Mar; 43(5):267-74. PubMed ID: 301618
    [No Abstract]   [Full Text] [Related]  

  • 6. Mechanical aortic valve replacement in children and adolescents after previous repair of congenital heart disease.
    Popov AF; Coskun KO; Tirilomis T; Schmitto JD; Hinz J; Kriebel T; Schoendube FA; Ruschewski W
    Artif Organs; 2009 Nov; 33(11):915-21. PubMed ID: 19817736
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Membrane and bubble oxygenator: a clinical comparison in patients undergoing aortocoronary bypass procedures.
    Alon L; Turina M; Gattiker R
    Herz; 1979 Feb; 4(1):56-62. PubMed ID: 108187
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Effect of osmolarity of the perfusion medium on the osmotic properties of the blood during open heart surgery with artificial circulation].
    Khapiĭ KhKh; Agamaliev KT
    Anesteziol Reanimatol; 1981; (5):49-52. PubMed ID: 7325385
    [No Abstract]   [Full Text] [Related]  

  • 9. [A comparative evaluation of the changes in the lungs during open-heart operations using contact and membrane oxygenators].
    Goncharov IuV; Cherkas DD; Grigor'eva IuA; Skorik VI; Gorokhovatskiĭ IuI; Shilov VV
    Vestn Khir Im I I Grek; 1994; 152(3-4):3-6. PubMed ID: 7709525
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Aortic and mitral valve surgery on the beating heart is lowering cardiopulmonary bypass and aortic cross clamp time.
    Gersak B; Sutlic Z
    Heart Surg Forum; 2002; 5(2):182-6. PubMed ID: 12125670
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The use of valve prostheses in congenital heart diseases in children and adolescents. A preliminary report of 29 cases.
    Taguchi K; Sasaki N; Matsuura Y; Nakamura S; Tamura M; Yoshizaki E
    J Thorac Cardiovasc Surg; 1968 Jun; 55(6):800-10. PubMed ID: 5651654
    [No Abstract]   [Full Text] [Related]  

  • 12. A comparison of membrane and bubble oxygenation as used in cardiopulmonary bypass in patients. The importance of pericardial blood as a source of hemolysis.
    Siderys H; Herod GT; Halbrook H; Pittman JN; Rubush JL; Kasebaker V; Berry GR
    J Thorac Cardiovasc Surg; 1975 May; 69(5):708-12. PubMed ID: 1079293
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Extracorporeal membrane oxygenation for postoperative cardiac support in children.
    Kanter KR; Pennington G; Weber TR; Zambie MA; Braun P; Martychenko V
    J Thorac Cardiovasc Surg; 1987 Jan; 93(1):27-35. PubMed ID: 3796029
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Causes of hemolysis during extracorporeal circulation].
    Kobakhidze EA; Lifliandskiĭ DB; Soboleva ER; Abdurakhimov Z
    Anesteziol Reanimatol; 1983; (4):23-5. PubMed ID: 6638577
    [No Abstract]   [Full Text] [Related]  

  • 15. Pediatric application of Landé-Edwards membrane oxygenator. Continuous perfusion and hypothermic arrest techniques.
    Wright JS; McCulloch CH; Torda TA; Stacey R; Hicks RG
    J Thorac Cardiovasc Surg; 1973 Apr; 65(4):503-10. PubMed ID: 4697438
    [No Abstract]   [Full Text] [Related]  

  • 16. [Effect of valve type and valve function on chronic intravascular hemolysis after alloprosthetic mitral and aortic valve replacement].
    Horstkotte D; Aul C; Seipel L; Körfer R; Budde T; Schulte HD; Bircks W; Loogen F
    Z Kardiol; 1983 Feb; 72(2):119-31. PubMed ID: 6845808
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Minimally invasive closed circuit versus standard extracorporeal circulation for aortic valve replacement.
    Castiglioni A; Verzini A; Pappalardo F; Colangelo N; Torracca L; Zangrillo A; Alfieri O
    Ann Thorac Surg; 2007 Feb; 83(2):586-91. PubMed ID: 17257992
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Open-heart and aortic surgery with extracorporeal circulation. Experiences of 150 cases.
    Larmi TK; Kärkölä P; Takkunen J
    Ann Chir Gynaecol Fenn; 1974; 63(4):249-57. PubMed ID: 4547263
    [No Abstract]   [Full Text] [Related]  

  • 19. Intermediate-term results after the aortic valve replacement using bileaflet mechanical prosthetic valve in children.
    Masuda M; Kado H; Ando Y; Shiose A; Nakano T; Fukae K; Tanoue Y; Tominaga R
    Eur J Cardiothorac Surg; 2008 Jul; 34(1):42-7. PubMed ID: 18479932
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Mechanical valve replacement in congenital heart disease.
    Fiane AE; Lindberg HL; Saatvedt K; Svennevig JL
    J Heart Valve Dis; 1996 May; 5(3):337-42. PubMed ID: 8793687
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.