These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

103 related articles for article (PubMed ID: 10800039)

  • 1. Correction for acceleration-induced displacement artifacts in phase contrast imaging.
    Thunberg P; Wigström L; Wranne B; Engvall J; Karlsson M
    Magn Reson Med; 2000 May; 43(5):734-8. PubMed ID: 10800039
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Correction for displacement artifacts in 3D phase contrast imaging.
    Thunberg P; Wigström L; Ebbers T; Karlsson M
    J Magn Reson Imaging; 2002 Nov; 16(5):591-7. PubMed ID: 12412037
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Understanding acceleration-induced displacement artifacts in phase-contrast MR velocity measurements.
    Frayne R; Rutt BK
    J Magn Reson Imaging; 1995; 5(2):207-15. PubMed ID: 7766984
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Regularization of flow streamlines in multislice phase-contrast MR imaging.
    Fatouraee N; Amini AA
    IEEE Trans Med Imaging; 2003 Jun; 22(6):699-709. PubMed ID: 12872945
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Effects of acceleration on the accuracy of MR phase velocity measurements.
    Oshinski JN; Ku DN; Bohning DE; Pettigrew RI
    J Magn Reson Imaging; 1992; 2(6):665-70. PubMed ID: 1446110
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Elimination of oblique flow artifacts in magnetic resonance imaging.
    Frank LR; Crawley AP; Buxton RB
    Magn Reson Med; 1992 Jun; 25(2):299-307. PubMed ID: 1614313
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Mapping aortic hemodynamics using 3D cine phase contrast magnetic resonance parallel imaging: evaluation of an anisotropic diffusion filter.
    Tresoldi D; Cadioli M; Ponzini R; Esposito A; De Cobelli F; Morbiducci U; Rizzo G
    Magn Reson Med; 2014 Apr; 71(4):1621-31. PubMed ID: 23798317
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Flow quantification using fast cine phase-contrast MR imaging, conventional cine phase-contrast MR imaging, and Doppler sonography: in vitro and in vivo validation.
    Lee VS; Spritzer CE; Carroll BA; Pool LG; Bernstein MA; Heinle SK; MacFall JR
    AJR Am J Roentgenol; 1997 Oct; 169(4):1125-31. PubMed ID: 9308476
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Combined analysis of spatial and velocity displacement artifacts in phase contrast measurements of complex flows.
    Steinman DA; Ethier CR; Rutt BK
    J Magn Reson Imaging; 1997; 7(2):339-46. PubMed ID: 9090588
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Virtual injections using 4D flow MRI with displacement corrections and constrained probabilistic streamlines.
    Roberts GS; Loecher MW; Spahic A; Johnson KM; Turski PA; Eisenmenger LB; Wieben O
    Magn Reson Med; 2022 May; 87(5):2495-2511. PubMed ID: 34971458
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Velocity-encoded cine MR imaging in aortic coarctation: functional assessment of hemodynamic events.
    Hom JJ; Ordovas K; Reddy GP
    Radiographics; 2008; 28(2):407-16. PubMed ID: 18349448
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Quantification of turbulence and velocity in stenotic flow using spiral three-dimensional phase-contrast MRI.
    Petersson S; Dyverfeldt P; Sigfridsson A; Lantz J; Carlhäll CJ; Ebbers T
    Magn Reson Med; 2016 Mar; 75(3):1249-55. PubMed ID: 25846511
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Preclinical 4D-flow magnetic resonance phase contrast imaging of the murine aortic arch.
    Braig M; Leupold J; Menza M; Russe M; Ko CW; Hennig J; von Elverfeldt D
    PLoS One; 2017; 12(11):e0187596. PubMed ID: 29117252
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Diagnostic value of the flow profile in the distal descending aorta by phase-contrast magnetic resonance for predicting severe coarctation of the aorta.
    Muzzarelli S; Ordovas KG; Hope MD; Meadows JJ; Higgins CB; Meadows AK
    J Magn Reson Imaging; 2011 Jun; 33(6):1440-6. PubMed ID: 21591014
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Magnetic resonance volume flow and jet velocity mapping in aortic coarctation.
    Mohiaddin RH; Kilner PJ; Rees S; Longmore DB
    J Am Coll Cardiol; 1993 Nov; 22(5):1515-21. PubMed ID: 8227813
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Ripple artifact reduction using slice overlap in slice encoding for metal artifact correction.
    den Harder JC; van Yperen GH; Blume UA; Bos C
    Magn Reson Med; 2015 Jan; 73(1):318-24. PubMed ID: 24488701
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Fast acceleration-encoded magnetic resonance imaging.
    Forster J; Sieverding L; Breuer J; Lutz O; Schick F
    Med Phys; 2001 Jan; 28(1):28-35. PubMed ID: 11213919
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Evaluation of magnetic resonance velocimetry for steady flow.
    Ku DN; Biancheri CL; Pettigrew RI; Peifer JW; Markou CP; Engels H
    J Biomech Eng; 1990 Nov; 112(4):464-72. PubMed ID: 2273875
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Estimation of pressure gradients in pulsatile flow from magnetic resonance acceleration measurements.
    Tasu JP; Mousseaux E; Delouche A; Oddou C; Jolivet O; Bittoun J
    Magn Reson Med; 2000 Jul; 44(1):66-72. PubMed ID: 10893523
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Magnetic resonance imaging kappa-space segmentation using phase-encoding groups the accuracy of quantitative measurements of pulsatile flow.
    Li H; Clarke GD; NessAvier M; Liu H; Peshock R
    Med Phys; 1995 Apr; 22(4):391-9. PubMed ID: 7609719
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.