278 related articles for article (PubMed ID: 10806882)
1. [Magnetic resonance tomography with endorectal coil for examination of prostate and seminal vesicles].
Rørvik J
Tidsskr Nor Laegeforen; 2000 Feb; 120(6):689-92. PubMed ID: 10806882
[TBL] [Abstract][Full Text] [Related]
2. [MRI of prostate cancer using three different coil systems: image quality, tumor detection, and staging].
Beyersdorff D; Darsow U; Stephan C; Schnorr D; Loening S; Taupitz M
Rofo; 2003 Jun; 175(6):799-805. PubMed ID: 12811693
[TBL] [Abstract][Full Text] [Related]
3. 3 Tesla magnetic resonance imaging of the prostate with combined pelvic phased-array and endorectal coils; Initial experience(1).
Bloch BN; Rofsky NM; Baroni RH; Marquis RP; Pedrosa I; Lenkinski RE
Acad Radiol; 2004 Aug; 11(8):863-7. PubMed ID: 15288036
[TBL] [Abstract][Full Text] [Related]
4. [Preoperative T-staging of prostatic carcinoma: endorectal magnetic resonance tomography compared with other imaging and clinical methods].
Böni RA; Hutter BE; Trinkler F; Jochum W; Pestalozzi D; Krestin GP
Rofo; 1996 Aug; 165(2):152-8. PubMed ID: 8924668
[TBL] [Abstract][Full Text] [Related]
5. [Magnetic resonance with an endorectal coil and a fast spin echo sequence in the staging of prostatic carcinoma. The correlation with histopathological data].
Masi A; Olmastroni M; Marin E; Consalvo M; Lascialfari L; Ricupero L; Nicita G; Villari D; Amorosi A; Villari N
Radiol Med; 1997 Nov; 94(5):496-502. PubMed ID: 9465216
[TBL] [Abstract][Full Text] [Related]
6. MR imaging of the prostate at 3 Tesla: comparison of an external phased-array coil to imaging with an endorectal coil at 1.5 Tesla.
Sosna J; Pedrosa I; Dewolf WC; Mahallati H; Lenkinski RE; Rofsky NM
Acad Radiol; 2004 Aug; 11(8):857-62. PubMed ID: 15354305
[TBL] [Abstract][Full Text] [Related]
7. [Magnetic resonance with endorectal coil in the local staging of prostatic carcinoma. Comparison with histologic macrosections in 40 cases].
Torricelli P; Iadanza M; De Santis M; Pollastri CA; Cesinaro AM; Trentini G; Romagnoli R
Radiol Med; 1999 Jun; 97(6):491-8. PubMed ID: 10478207
[TBL] [Abstract][Full Text] [Related]
8. [Locoregional staging of prostatic carcinoma: accuracy of magnetic resonance with endorectal coil in 75 patients treated with radical prostatectomy].
Gualdi GF; Casciani E; Ferriano MG; Polettini E
Radiol Med; 1998 May; 95(5):498-505. PubMed ID: 9687928
[TBL] [Abstract][Full Text] [Related]
9. Hormonal ablation of prostatic cancer: effects on prostate morphology, tumor detection, and staging by endorectal coil MR imaging.
Chen M; Hricak H; Kalbhen CL; Kurhanewicz J; Vigneron DB; Weiss JM; Carroll PR
AJR Am J Roentgenol; 1996 May; 166(5):1157-63. PubMed ID: 8615261
[TBL] [Abstract][Full Text] [Related]
10. [Endorectal magnetic resonance imaging of the prostate and bladder].
Sugimura Y; Hayashi N; Yamashita A; Kinbara H; Arima K; Tochigi H; Kawamura J
Hinyokika Kiyo; 1994 Jan; 40(1):31-6. PubMed ID: 7509118
[TBL] [Abstract][Full Text] [Related]
11. MR imaging of the prostate at 3.0T with external phased array coil - preliminary results.
Morakkabati-Spitz N; Bastian PJ; Gieseke J; Träber F; Kuhl CK; Wattjes MP; Müller SC; Schild HH
Eur J Med Res; 2008 Jun; 13(6):287-91. PubMed ID: 18558555
[TBL] [Abstract][Full Text] [Related]
12. Endorectal MRI for prediction of tumor site, tumor size, and local extension of prostate cancer.
Nakashima J; Tanimoto A; Imai Y; Mukai M; Horiguchi Y; Nakagawa K; Oya M; Ohigashi T; Marumo K; Murai M
Urology; 2004 Jul; 64(1):101-5. PubMed ID: 15245944
[TBL] [Abstract][Full Text] [Related]
13. Thirty-two-channel coil 3T magnetic resonance-guided biopsies of prostate tumor suspicious regions identified on multimodality 3T magnetic resonance imaging: technique and feasibility.
Hambrock T; Fütterer JJ; Huisman HJ; Hulsbergen-vandeKaa C; van Basten JP; van Oort I; Witjes JA; Barentsz JO
Invest Radiol; 2008 Oct; 43(10):686-94. PubMed ID: 18791410
[TBL] [Abstract][Full Text] [Related]
14. Endorectal magnetic resonance imaging staging of prostate cancer.
Chandra RV; Heinze S; Dowling R; Shadbolt C; Costello A; Pedersen J
ANZ J Surg; 2007 Oct; 77(10):860-5. PubMed ID: 17803549
[TBL] [Abstract][Full Text] [Related]
15. [Magnetic resonance tomography in prostatic carcinoma and benign prostatic diseases with an endorectal and a new combined endorectal body phased-array coil].
Engelhard K; Hollenbach HP; Ott G; Hausmann J; Risse W; Riedl C
Rontgenpraxis; 1999; 52(7):214-23. PubMed ID: 10605323
[No Abstract] [Full Text] [Related]
16. Comparison of phased-array 3.0-T and endorectal 1.5-T magnetic resonance imaging in the evaluation of local staging accuracy for prostate cancer.
Park BK; Kim B; Kim CK; Lee HM; Kwon GY
J Comput Assist Tomogr; 2007; 31(4):534-8. PubMed ID: 17882027
[TBL] [Abstract][Full Text] [Related]
17. Experience improves staging accuracy of endorectal magnetic resonance imaging in prostate cancer: what is the learning curve?
Latchamsetty KC; Borden LS; Porter CR; Lacrampe M; Vaughan M; Lin E; Conti N; Wright JL; Corman JM
Can J Urol; 2007 Feb; 14(1):3429-34. PubMed ID: 17324322
[TBL] [Abstract][Full Text] [Related]
18. The role of magnetic resonance imaging in targeting prostate cancer in patients with previous negative biopsies and elevated prostate-specific antigen levels.
Lawrentschuk N; Fleshner N
BJU Int; 2009 Mar; 103(6):730-3. PubMed ID: 19154475
[TBL] [Abstract][Full Text] [Related]
19. [Non-granulomatous prostatitis: MRI image with endorectal surface coil ("Endo-MRI")].
Szolar DH; Ranner G; Preidler KW; Lax S
Aktuelle Radiol; 1995 Jan; 5(1):67-9. PubMed ID: 7888435
[TBL] [Abstract][Full Text] [Related]
20. Staging of prostate cancer with endorectal MR imaging: lessons from a learning curve.
Harris RD; Schned AR; Heaney JA
Radiographics; 1995 Jul; 15(4):813-29; discussion 829-32. PubMed ID: 7569131
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]