BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

126 related articles for article (PubMed ID: 10808219)

  • 21. Perceptibility of defects in an aluminum test object: a comparison of the RVG-S and first generation VIXA systems with and without added niobium filtration.
    Wakoh M; Farman AG; Scarfe WC; Kelly MS; Kuroyanagi K
    Dentomaxillofac Radiol; 1995 Nov; 24(4):211-4. PubMed ID: 9161163
    [TBL] [Abstract][Full Text] [Related]  

  • 22. [Digital radiology using the DIGORA registration technic].
    van der Stelt PF
    Rev Belge Med Dent (1984); 1996; 51(2):93-100. PubMed ID: 9289753
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Physical evaluation of a system for direct digital intra-oral radiography based on a charge-coupled device.
    Yoshiura K; Stamatakis HC; Welander U; McDavid WD; Shi XQ; Ban S; Kawazu T; Tatsumi M; Kanda S
    Dentomaxillofac Radiol; 1999 Sep; 28(5):277-83. PubMed ID: 10490745
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Dependency of dose response of five charge-coupled device-based digital intra-oral radiographic systems on tube voltage.
    Nishikawa K; Shibuya H; Wakoh M; Kuroyanagi K
    Dentomaxillofac Radiol; 1999 Nov; 28(6):364-7. PubMed ID: 10578191
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Experience of Norwegian general dental practitioners with solid state and storage phosphor detectors.
    Wenzel A; Møystad A
    Dentomaxillofac Radiol; 2001 Jul; 30(4):203-8. PubMed ID: 11681481
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Assessment of image quality in dental radiography, part 2: optimum exposure conditions for detection of small mass changes in 6 intraoral radiography systems.
    Yoshiura K; Kawazu T; Chikui T; Tatsumi M; Tokumori K; Tanaka T; Kanda S
    Oral Surg Oral Med Oral Pathol Oral Radiol Endod; 1999 Jan; 87(1):123-9. PubMed ID: 9927091
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Comparison of Efficiency and Image Quality of Photostimulable Phosphor Plate and Charge-Coupled Device Receptors in Dental Radiography.
    Zhang W; Huynh C; Jadhav A; Pinales J; Arvizu L; Tsai J; Flores N
    J Dent Educ; 2019 Oct; 83(10):1205-1212. PubMed ID: 31235501
    [TBL] [Abstract][Full Text] [Related]  

  • 28. On the dynamic range of different X-ray photon detectors in intra-oral radiography. A comparison of image quality in film, charge-coupled device and storage phosphor systems.
    Borg E; Gröndahl HG
    Dentomaxillofac Radiol; 1996 Apr; 25(2):82-8. PubMed ID: 9446978
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Dental digital radiography.
    Moore WS
    Tex Dent J; 2002 May; 119(5):404-12. PubMed ID: 12046403
    [TBL] [Abstract][Full Text] [Related]  

  • 30. A comparison of 18 different x-ray detectors currently used in dentistry.
    Farman AG; Farman TT
    Oral Surg Oral Med Oral Pathol Oral Radiol Endod; 2005 Apr; 99(4):485-9. PubMed ID: 15772598
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Comparison of the psychophysical properties of various intraoral film and digital systems by means of the perceptibility curve test.
    Yoshiura K; Welander U; McDavid WD; Li G; Shi XQ; Nakayama E; Shimizu M; Okamura K; Kanda S
    Dentomaxillofac Radiol; 2004 Mar; 33(2):98-102. PubMed ID: 15314001
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Evaluation of physical properties of different digital intraoral sensors.
    Al-Rawi W; Teich S
    Compend Contin Educ Dent; 2013 Sep; 34(8):e76-83. PubMed ID: 24568289
    [TBL] [Abstract][Full Text] [Related]  

  • 33. High resolution charge-coupled device sensor vs. medium resolution photostimulable phosphor plate digital receptors for detection of root fractures in vitro.
    Wenzel A; Kirkevang LL
    Dent Traumatol; 2005 Feb; 21(1):32-6. PubMed ID: 15660754
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Digital radiography: the standard of care.
    Samaras CD
    Compend Contin Educ Dent; 2008 Oct; 29(8):506, 508-9. PubMed ID: 18935789
    [No Abstract]   [Full Text] [Related]  

  • 35. Effects of calibration and automatic greyscale adjustment on detectability of simulated bone lesions using a storage phosphor system.
    Versteeg CH; Sanderink GC; van Ginkel FC; van der Stelt PF
    Dentomaxillofac Radiol; 1998 Jul; 27(4):240-4. PubMed ID: 9780903
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Comments on noise and resolution of the DenOptix radiography system.
    Couture RA
    Oral Surg Oral Med Oral Pathol Oral Radiol Endod; 2003 Jun; 95(6):746-51. PubMed ID: 12789159
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Principles of digital imaging.
    van der Stelt PF
    Dent Clin North Am; 2000 Apr; 44(2):237-48, v. PubMed ID: 10740766
    [TBL] [Abstract][Full Text] [Related]  

  • 38. The perceptibility curve test applied to direct digital dental radiography.
    Yoshiura K; Stamatakis H; Shi XQ; Welander U; McDavid WD; Kristoffersen J; Tronje G
    Dentomaxillofac Radiol; 1998 May; 27(3):131-5. PubMed ID: 9693524
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Perceptibility curve test for digital radiographs before and after correction for attenuation and correction for attenuation and visual response.
    Li G; Welander U; Yoshiura K; Shi XQ; McDavid WD
    Dentomaxillofac Radiol; 2003 Nov; 32(6):372-8. PubMed ID: 15070839
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Bitewing examination with four digital receptors.
    Bahrami G; Hagstrøm C; Wenzel A
    Dentomaxillofac Radiol; 2003 Sep; 32(5):317-21. PubMed ID: 14709607
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.