These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
198 related articles for article (PubMed ID: 10815833)
1. Mechanical performance of standard and cannulated 4.0-mm cancellous bone screws. Brown GA; McCarthy T; Bourgeault CA; Callahan DJ J Orthop Res; 2000 Mar; 18(2):307-12. PubMed ID: 10815833 [TBL] [Abstract][Full Text] [Related]
2. Fine thread versus coarse thread. A comparison of the maximum holding power. Gausepohl T; Möhring R; Pennig D; Koebke J Injury; 2001 Dec; 32 Suppl 4():SD1-7. PubMed ID: 11812471 [TBL] [Abstract][Full Text] [Related]
3. Pullout strengths of cannulated and noncannulated cancellous bone screws. Thompson JD; Benjamin JB; Szivek JA Clin Orthop Relat Res; 1997 Aug; (341):241-9. PubMed ID: 9269180 [TBL] [Abstract][Full Text] [Related]
4. A comparison of screw insertion torque and pullout strength. Ricci WM; Tornetta P; Petteys T; Gerlach D; Cartner J; Walker Z; Russell TA J Orthop Trauma; 2010 Jun; 24(6):374-8. PubMed ID: 20502221 [TBL] [Abstract][Full Text] [Related]
5. Investigation of fixation screw pull-out strength on human spine. Zhang QH; Tan SH; Chou SM J Biomech; 2004 Apr; 37(4):479-85. PubMed ID: 14996559 [TBL] [Abstract][Full Text] [Related]
6. Effect of thread pitch on pull-out strength of laparoscopic myoma screws. Tintara H; Aiyarak P; Mitarnun W; Geater A J Obstet Gynaecol Res; 2006 Aug; 32(4):428-33. PubMed ID: 16882270 [TBL] [Abstract][Full Text] [Related]
7. Proximal half angle of the screw thread is a critical design variable affecting the pull-out strength of cancellous bone screws. Wang Y; Mori R; Ozoe N; Nakai T; Uchio Y Clin Biomech (Bristol); 2009 Nov; 24(9):781-5. PubMed ID: 19699567 [TBL] [Abstract][Full Text] [Related]
8. Effects of bone materials on the screw pull-out strength in human spine. Zhang QH; Tan SH; Chou SM Med Eng Phys; 2006 Oct; 28(8):795-801. PubMed ID: 16414303 [TBL] [Abstract][Full Text] [Related]
9. [Experimental study of improved threading of bone screws]. Ungethüm M; Blömer W; Reichle V Aktuelle Traumatol; 1983 Jun; 13(3):128-32. PubMed ID: 6136166 [TBL] [Abstract][Full Text] [Related]
10. Mechanical tests and finite element models for bone holding power of tibial locking screws. Hou SM; Hsu CC; Wang JL; Chao CK; Lin J Clin Biomech (Bristol); 2004 Aug; 19(7):738-45. PubMed ID: 15288461 [TBL] [Abstract][Full Text] [Related]
11. Factors affecting the pullout strength of cancellous bone screws. Chapman JR; Harrington RM; Lee KM; Anderson PA; Tencer AF; Kowalski D J Biomech Eng; 1996 Aug; 118(3):391-8. PubMed ID: 8872262 [TBL] [Abstract][Full Text] [Related]
12. Analysis of the pull-out strength of screws and pegs used to secure tibial components following total knee arthroplasty. Finlay JB; Harada I; Bourne RB; Rorabeck CH; Hardie R; Scott MA Clin Orthop Relat Res; 1989 Oct; (247):220-31. PubMed ID: 2791391 [TBL] [Abstract][Full Text] [Related]
13. Increasing bending strength and pullout strength in conical pedicle screws: biomechanical tests and finite element analyses. Chao CK; Hsu CC; Wang JL; Lin J J Spinal Disord Tech; 2008 Apr; 21(2):130-8. PubMed ID: 18391719 [TBL] [Abstract][Full Text] [Related]
14. Comparison of pullout strength of small-diameter cannulated and solid-core screws. Kissel CG; Friedersdorf SC; Foltz DS; Snoeyink T J Foot Ankle Surg; 2003; 42(6):334-8. PubMed ID: 14688774 [TBL] [Abstract][Full Text] [Related]
16. Compression forces generated by Mini bone screws--a comparative study done on bone model. Adla DN; Kitsis C; Miles AW Injury; 2005 Jan; 36(1):65-70. PubMed ID: 15589916 [TBL] [Abstract][Full Text] [Related]
17. Relationship between thread depth and fixation strength in cancellous bone screw. Yu A; Imade S; Furuya S; Nakazawa K; Shiraishi K; Kawamura T; Uchio Y J Orthop Sci; 2023 Sep; 28(5):1143-1148. PubMed ID: 35953407 [TBL] [Abstract][Full Text] [Related]
18. Biomechanical comparison of anatomic trajectory pedicle screw versus injectable calcium sulfate graft-augmented pedicle screw for salvage in cadaveric thoracic bone. Derincek A; Wu C; Mehbod A; Transfeldt EE J Spinal Disord Tech; 2006 Jun; 19(4):286-91. PubMed ID: 16778665 [TBL] [Abstract][Full Text] [Related]
19. [Factors influencing the anchoring stability of spinal bone screws--an experimental study]. Hackenberg L; Clahsen H; Halm H Z Orthop Ihre Grenzgeb; 1998; 136(5):451-6. PubMed ID: 9823642 [TBL] [Abstract][Full Text] [Related]
20. The dynamic natures of implant loading. Wang RF; Kang B; Lang LA; Razzoog ME J Prosthet Dent; 2009 Jun; 101(6):359-71. PubMed ID: 19463663 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]