124 related articles for article (PubMed ID: 10826640)
1. A biosensor for the detection of gas toxicity using a recombinant bioluminescent bacterium.
Gil GC; Mitchell RJ; Chang ST; Gu MB
Biosens Bioelectron; 2000 Mar; 15(1-2):23-30. PubMed ID: 10826640
[TBL] [Abstract][Full Text] [Related]
2. Enhancement in the sensitivity of a gas biosensor by using an advanced immobilization of a recombinant bioluminescent bacterium.
Gil GC; Kim YJ; Gu MB
Biosens Bioelectron; 2002 May; 17(5):427-32. PubMed ID: 11888733
[TBL] [Abstract][Full Text] [Related]
3. A portable toxicity biosensor using freeze-dried recombinant bioluminescent bacteria.
Choi SH; Gu MB
Biosens Bioelectron; 2002 May; 17(5):433-40. PubMed ID: 11888734
[TBL] [Abstract][Full Text] [Related]
4. Soil biosensor for the detection of PAH toxicity using an immobilized recombinant bacterium and a biosurfactant.
Gu MB; Chang ST
Biosens Bioelectron; 2001 Dec; 16(9-12):667-74. PubMed ID: 11679243
[TBL] [Abstract][Full Text] [Related]
5. A bioluminescent sensor for high throughput toxicity classification.
Kim BC; Gu MB
Biosens Bioelectron; 2003 Aug; 18(8):1015-21. PubMed ID: 12782464
[TBL] [Abstract][Full Text] [Related]
6. Monitoring and classification of PAH toxicity using an immobilized bioluminescent bacteria.
Lee HJ; Villaume J; Cullen DC; Kim BC; Gu MB
Biosens Bioelectron; 2003 May; 18(5-6):571-7. PubMed ID: 12706564
[TBL] [Abstract][Full Text] [Related]
7. Evaluation of a high throughput toxicity biosensor and comparison with a Daphnia magna bioassay.
Kim BC; Park KS; Kim SD; Gu MB
Biosens Bioelectron; 2003 May; 18(5-6):821-6. PubMed ID: 12706597
[TBL] [Abstract][Full Text] [Related]
8. Development of a biosensor for on-line detection of tributyltin with a recombinant bioluminescent Escherichia coli strain.
Thouand G; Horry H; Durand MJ; Picart P; Bendriaa L; Daniel P; DuBow MS
Appl Microbiol Biotechnol; 2003 Aug; 62(2-3):218-25. PubMed ID: 12883867
[TBL] [Abstract][Full Text] [Related]
9. A multi-channel continuous toxicity monitoring system using recombinant bioluminescent bacteria for classification of toxicity.
Gu MB; Gil GC
Biosens Bioelectron; 2001 Dec; 16(9-12):661-6. PubMed ID: 11679242
[TBL] [Abstract][Full Text] [Related]
10. Bioluminescent liquid light guide pad biosensor for indoor air toxicity monitoring.
Eltzov E; Cohen A; Marks RS
Anal Chem; 2015 Apr; 87(7):3655-61. PubMed ID: 25775008
[TBL] [Abstract][Full Text] [Related]
11. An optical detection module-based biosensor using fortified bacterial beads for soil toxicity assessment.
Bae JW; Seo HB; Belkin S; Gu MB
Anal Bioanal Chem; 2020 May; 412(14):3373-3381. PubMed ID: 32072206
[TBL] [Abstract][Full Text] [Related]
12. Some observations in freeze-drying of recombinant bioluminescent Escherichia coli for toxicity monitoring.
Gu MB; Choi SH; Kim SW
J Biotechnol; 2001 Jun; 88(2):95-105. PubMed ID: 11403844
[TBL] [Abstract][Full Text] [Related]
13. A dip-stick type biosensor using bioluminescent bacteria encapsulated in color-coded alginate microbeads for detection of water toxicity.
Jung I; Seo HB; Lee JE; Kim BC; Gu MB
Analyst; 2014 Sep; 139(18):4696-701. PubMed ID: 25057512
[TBL] [Abstract][Full Text] [Related]
14. Development of a quantitative optical biochip based on a double integrating sphere system that determines absolute photon number in bioluminescent solution: application to quantum yield scale realization.
Daniel R; Almog R; Sverdlov Y; Yagurkroll S; Belkin S; Shacham-Diamand Y
Appl Opt; 2009 Jun; 48(17):3216-24. PubMed ID: 19516370
[TBL] [Abstract][Full Text] [Related]
15. A multi-channel bioluminescent bacterial biosensor for the on-line detection of metals and toxicity. Part II: technical development and proof of concept of the biosensor.
Charrier T; Chapeau C; Bendria L; Picart P; Daniel P; Thouand G
Anal Bioanal Chem; 2011 May; 400(4):1061-70. PubMed ID: 21061000
[TBL] [Abstract][Full Text] [Related]
16. A miniature bioreactor for sensing toxicity using recombinant bioluminescent Escherichia coli cells.
Gu MB; Dhurjati PS; Van Dyk TK; LaRossa RA
Biotechnol Prog; 1996; 12(3):393-7. PubMed ID: 8652123
[TBL] [Abstract][Full Text] [Related]
17. Use of a gas-sensor array for detecting volatile organic compounds (VOC) in chemically induced cells.
Pasini P; Powar N; Gutierrez-Osuna R; Daunert S; Roda A
Anal Bioanal Chem; 2004 Jan; 378(1):76-83. PubMed ID: 14615863
[TBL] [Abstract][Full Text] [Related]
18. Chemical-specific continuous biomonitoring using a recombinant bioluminescent bacterium DNT5 (nagR-nagAa::luxCDABE).
Lee JH; Mitchell RJ; Gu MB
J Biotechnol; 2007 Sep; 131(3):330-4. PubMed ID: 17716769
[TBL] [Abstract][Full Text] [Related]
19. Bioluminescent bioreporter pad biosensor for monitoring water toxicity.
Axelrod T; Eltzov E; Marks RS
Talanta; 2016; 149():290-297. PubMed ID: 26717844
[TBL] [Abstract][Full Text] [Related]
20. Online monitoring of water toxicity by use of bioluminescent reporter bacterial biochips.
Elad T; Almog R; Yagur-Kroll S; Levkov K; Melamed S; Shacham-Diamand Y; Belkin S
Environ Sci Technol; 2011 Oct; 45(19):8536-44. PubMed ID: 21875062
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]