These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
119 related articles for article (PubMed ID: 10826739)
1. In vitro characterization of the occurrence of hemolysis during extracorporeal blood circulation using a mini hemodialyzer. Yang MC; Lin CC ASAIO J; 2000; 46(3):293-7. PubMed ID: 10826739 [TBL] [Abstract][Full Text] [Related]
2. Influence of design of the hemodialyzer inlet chamber on red blood cell damage during hemodialysis. Yang MC; Lin CC ASAIO J; 2001; 47(1):92-6. PubMed ID: 11199324 [TBL] [Abstract][Full Text] [Related]
3. In Vitro Comparative Assessment of Mechanical Blood Damage Induced by Different Hemodialysis Treatments. Sakota R; Lodi CA; Sconziano SA; Beck W; Bosch JP Artif Organs; 2015 Dec; 39(12):1015-23. PubMed ID: 25981394 [TBL] [Abstract][Full Text] [Related]
4. Decreased hemodialysis circuit pressures indicating postpump tubing kinks: a retrospective investigation of hemolysis in five patients. Malinauskas RA Hemodial Int; 2008 Jul; 12(3):383-93. PubMed ID: 18638097 [TBL] [Abstract][Full Text] [Related]
5. Red blood cell damage from extracorporeal circulation in hemodialysis. Polaschegg HD Semin Dial; 2009; 22(5):524-31. PubMed ID: 19558629 [TBL] [Abstract][Full Text] [Related]
6. Blood and dialysate flow distributions in hollow-fiber hemodialyzers analyzed by computerized helical scanning technique. Ronco C; Brendolan A; Crepaldi C; Rodighiero M; Scabardi M J Am Soc Nephrol; 2002 Jan; 13 Suppl 1():S53-61. PubMed ID: 11792763 [TBL] [Abstract][Full Text] [Related]
10. Device and technique for extracorporeal blood volume sequestration during hemodialysis. Wimmer J; Bachler I; Haditsch B; Stadlbauer V; Holzer H; Schneditz D ASAIO J; 2006; 52(6):662-9. PubMed ID: 17117056 [TBL] [Abstract][Full Text] [Related]
11. Hemodialysis using a valveless pulsatile blood pump. Lee K; Mun CH; Lee SR; Min BG; Yoo KJ; Park YW; Won YS ASAIO J; 2008; 54(2):191-6. PubMed ID: 18356654 [TBL] [Abstract][Full Text] [Related]
13. Hemolysis test of disposable type vibrating flow pump. Kobayashi S; Nitta S; Yambe T; Sonobe T; Naganuma S; Hashimoto H Artif Organs; 1997 Jul; 21(7):691-3. PubMed ID: 9212940 [TBL] [Abstract][Full Text] [Related]
14. Hemorheological effects of mechanical factors on blood cell damage in extracorporeal circulation: significance of sub-hemolytic trauma. Ohshima N Biorheology; 1978; 15(3-4):295-302. PubMed ID: 737329 [No Abstract] [Full Text] [Related]
15. Vitamin E-bonded hemodialyzer improves atherosclerosis associated with a rheological improvement of circulating red blood cells. Kobayashi S; Moriya H; Aso K; Ohtake T Kidney Int; 2003 May; 63(5):1881-7. PubMed ID: 12675867 [TBL] [Abstract][Full Text] [Related]
16. The plastic mesh support twin-coil hemodialyzer: ultrafiltration, volume, erythrocyte recovery, and safety. Easterling RE; Haig OG; Greene JA Trans Am Soc Artif Intern Organs; 1968; 14():114-20. PubMed ID: 5701522 [No Abstract] [Full Text] [Related]
17. Red cell injury assessed in a numeric model of a peripheral dialysis needle. De Wachter DS; Verdonck PR; Verhoeven RF; Hombrouckx RO ASAIO J; 1996; 42(5):M524-9. PubMed ID: 8944934 [TBL] [Abstract][Full Text] [Related]
18. Experimental study on hemolysis in centrifugal blood pumps: improvement of flow visualization method. Ahmed S; Funakubo A; Sakuma I; Fukui Y; Dohi T Artif Organs; 1999 Jun; 23(6):542-6. PubMed ID: 10392282 [TBL] [Abstract][Full Text] [Related]
19. Re-evaluation of Pre-pump Arterial Pressure to Avoid Inadequate Dialysis and Hemolysis: Importance of Prepump Arterial Pressure Monitoring in Hemodialysis Patients. Shibata E; Nagai K; Takeuchi R; Noda Y; Makino T; Chikata Y; Hann M; Yoshimoto S; Ono H; Ueda S; Tamaki M; Murakami T; Matsuura M; Abe H; Doi T Artif Organs; 2015 Jul; 39(7):627-34. PubMed ID: 25940509 [TBL] [Abstract][Full Text] [Related]