BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

120 related articles for article (PubMed ID: 10828565)

  • 1. Dosimetry calculation for a novel phosphorus-32-impregnated balloon angioplasty catheter for intravascular brachytherapy.
    Yue N; Nath R; Hehrlein C
    Cardiovasc Radiat Med; 1999; 1(4):349-57. PubMed ID: 10828565
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Dosimetric penumbra effects in catheter-based intravascular brachytherapy using a centered photon or beta line source.
    Yue N; Nath R; Roberts K
    Cardiovasc Radiat Med; 2000; 2(1):32-8. PubMed ID: 11229060
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Effects of off-centering on dose uniformity along and around blood vessels undergoing catheter-based intravascular brachytherapy.
    Nath R; Yue N
    Cardiovasc Radiat Med; 2004; 5(2):88-96. PubMed ID: 15464946
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A novel balloon angioplasty catheter impregnated with beta-particle emitting radioisotopes for vascular brachytherapy to prevent restenosis; first in vivo results.
    Hehrlein C; Kovacs A; Wolf GK; Yue N; Nath R
    Eur Heart J; 2000 Dec; 21(24):2056-62. PubMed ID: 11102256
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Dosimetric penumbra effects in catheter-based intravascular brachytherapy using a centered photon or beta line source.
    Yue N; Nath R; Roberts K
    Cardiovasc Radiat Med; 2001 Jan; 2(1):32-38. PubMed ID: 11068253
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Dosimetry characterization of 32P catheter-based vascular brachytherapy source wire.
    Mourtada FA; Soares CG; Seltzer SM; Lott SH
    Med Phys; 2000 Aug; 27(8):1770-6. PubMed ID: 10984223
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Effects of vessel curvature on dose distributions in catheter-based intravascular brachytherapy for various radionuclides.
    Yue N; Roberts K; Nath R
    Cardiovasc Radiat Med; 2004; 5(3):142-50. PubMed ID: 15721850
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Self-absorption correction for 32P, 198Au and 188Re stents: dose point kernel calculations versus Monte Carlo.
    Reynaert N; Häfeli UO
    Med Phys; 2001 Sep; 28(9):1883-97. PubMed ID: 11585219
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Monte Carlo calculations of dose distributions around 32P and 198Au stents for intravascular brachytherapy.
    Reynaert N; Verhaegen F; Taeymans Y; Van Eijkeren M; Thierens H
    Med Phys; 1999 Aug; 26(8):1484-91. PubMed ID: 10501047
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Radiation dose from a phosphorous-32 impregnated wire mesh vascular stent.
    Janicki C; Duggan DM; Coffey CW; Fischell DR; Fischell TA
    Med Phys; 1997 Mar; 24(3):437-45. PubMed ID: 9089595
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The investigation of 32P wire for catheter-based endovascular irradiation.
    Xu Z; Reinstein LE; Yang G; Pai S; Gluckman G; Almond PR
    Med Phys; 1997 Nov; 24(11):1788-92. PubMed ID: 9394287
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Post-dilatation intravascular brachytherapy trials on hypercholesterolemic rabbits using 32P-phosphate solutions in angioplasty balloons.
    Walichiewicz P; Wilczek K; Petelenz B; Jacheć W; Jochem J; Tomasik A; Bilski P; Gaca P; Banaszczuk J; Ihnatowicz J; Wodniecki J
    Cardiovasc Intervent Radiol; 2004; 27(1):42-50. PubMed ID: 15109228
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Dosimetry study of Re-188 liquid balloon for intravascular brachytherapy using polymer gel dosimeters and laser-beam optical CT scanner.
    Wuu CS; Schiff P; Maryanski MJ; Liu T; Borzillary S; Weinberger J
    Med Phys; 2003 Feb; 30(2):132-7. PubMed ID: 12607830
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Dosimetric effect of source centering and residual plaque for beta-emitting catheter based intravascular brachytherapy sources.
    Sehgal V; Li Z; Palta JR; Bolch WE
    Med Phys; 2001 Oct; 28(10):2162-71. PubMed ID: 11695779
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Dosimetry of beta emitting radionuclides for use in balloon angioplasty.
    Fox RA
    Australas Phys Eng Sci Med; 1997 Sep; 20(3):139-46. PubMed ID: 9409014
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Calculation of dose distribution near an innovative concentric balloon catheter for endovascular brachytherapy.
    Xu Z; Yang G; Reinstein LE; Cole PE
    Cardiovasc Radiat Med; 2000; 2(1):26-31. PubMed ID: 11229058
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Post-stenting intravascular brachytherapy trials on hypercholesterolemic rabbits using 32P liquid sources: implications for prevention of in-stent restenosis.
    Wilczek K; Walichiewicz P; Petelenz B; Jache W; Jochem J; Tomasik A; Bilski P; Snietura M; Wodniecki J
    Cardiovasc Intervent Radiol; 2002; 25(4):307-13. PubMed ID: 12042990
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Monte Carlo dose characterization of a new 90Sr/90Y source with balloon for intravascular brachytherapy.
    Wang R; Li XA; Lobdell J
    Med Phys; 2003 Jan; 30(1):27-33. PubMed ID: 12557975
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Monte Carlo characterization of a 32P source for intravascular brachytherapy.
    Wang R; Li XA
    Med Phys; 2001 Aug; 28(8):1776-85. PubMed ID: 11548949
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Dosimetry characterization of 32P intravascular brachytherapy source wires using Monte Carlo codes PENELOPE and GEANT4.
    Torres J; Buades MJ; Almansa JF; Guerrero R; Lallena AM
    Med Phys; 2004 Feb; 31(2):296-304. PubMed ID: 15000615
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.