These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

115 related articles for article (PubMed ID: 10828565)

  • 41. High dose rate brachytherapy for prevention of restenosis after percutaneous transluminal coronary angioplasty: preliminary dosimetric tests of a new source presentation.
    Popowski Y; Verin V; Papirov I; Nouet P; Rouzaud M; Grob E; Schwager M; Urban P; Rutishauser W; Kurtz JM
    Int J Radiat Oncol Biol Phys; 1995 Aug; 33(1):211-5. PubMed ID: 7642421
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Intracoronary radiation with a 32P source wire.
    Lee DP; Lo S; Forster KM; Tate DJ; Raizner A; Oesterle SN
    Herz; 1998 Sep; 23(6):362-5. PubMed ID: 9816522
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Dosimetry of a radioactive coronary balloon dilatation catheter for treatment of neointimal hyperplasia.
    Amols HI; Reinstein LE; Weinberger J
    Med Phys; 1996 Oct; 23(10):1783-8. PubMed ID: 8946374
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Intravascular irradiation using Re-186 liquid-filled balloon catheters: correlation between experimental and theoretical studies.
    McGoron AJ; Kassing WM; Thomas SR; Samaratunga RC; Pratt RG; Elson HR; Pipes DW
    Cardiovasc Radiat Med; 1999; 1(4):368-75. PubMed ID: 10828567
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Calibration of 32P "hot-wall" angioplasty-balloon-catheter sources by liquid-scintillation-spectrometry-based destructive radionuclidic assays.
    Collé R
    Appl Radiat Isot; 2001 Apr; 54(4):611-22. PubMed ID: 11225697
    [TBL] [Abstract][Full Text] [Related]  

  • 46. [Dosimetry fundamentals of endovascular therapy using Re-188 for the prevention of restenosis after angioplasty].
    Kotzerke J; Rentschler M; Glatting G; Schneider E; Stabin M; Knapp FF; Reske SN
    Nuklearmedizin; 1998 Mar; 37(2):68-72. PubMed ID: 9547753
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Dose effect of guidewire position in intravascular brachytherapy.
    Shih R; Hsu WL; Li XA
    Phys Med Biol; 2002 May; 47(10):1733-40. PubMed ID: 12069090
    [TBL] [Abstract][Full Text] [Related]  

  • 48. A segmented 32P source Monte Carlo model to derive AAPM TG-60 dosimetric parameters used for intravascular brachytherapy.
    Mourtada F; Soares CG; Horton JL
    Med Phys; 2004 Mar; 31(3):602-8. PubMed ID: 15070260
    [TBL] [Abstract][Full Text] [Related]  

  • 49. A retrospective analysis of catheter-based sources in intravascular brachytherapy.
    DeCunha J; Janicki C; Enger SA
    Brachytherapy; 2017; 16(3):586-596. PubMed ID: 28190783
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Comment on "Self-absorption correction for 32P, 198Au, and 188Re stents: dose point kernel calculations versus Monte Carlo".
    Janicki C
    Med Phys; 2002 Feb; 29(2):260-1. PubMed ID: 11865998
    [No Abstract]   [Full Text] [Related]  

  • 51. Determination of surface dose rate of indigenous (32)P patch brachytherapy source by experimental and Monte Carlo methods.
    Kumar S; Srinivasan P; Sharma SD; Saxena SK; Bakshi AK; Dash A; Babu DA; Sharma DN
    Appl Radiat Isot; 2015 Sep; 103():120-7. PubMed ID: 26086681
    [TBL] [Abstract][Full Text] [Related]  

  • 52. EGSnrc-based Monte Carlo dosimetry of CSA1 and CSA2 137Cs brachytherapy source models.
    Selvam TP; Sahoo S; Vishwakarma RS
    Med Phys; 2009 Sep; 36(9):3870-9. PubMed ID: 19810459
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Dosimetric considerations for catheter-based beta and gamma emitters in the therapy of neointimal hyperplasia in human coronary arteries.
    Amols HI; Zaider M; Weinberger J; Ennis R; Schiff PB; Reinstein LE
    Int J Radiat Oncol Biol Phys; 1996 Nov; 36(4):913-21. PubMed ID: 8960521
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Calculated and measured brachytherapy dosimetry parameters in water for the Xoft Axxent X-Ray Source: an electronic brachytherapy source.
    Rivard MJ; Davis SD; DeWerd LA; Rusch TW; Axelrod S
    Med Phys; 2006 Nov; 33(11):4020-32. PubMed ID: 17153382
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Application of a directional palladium-103 brachytherapy device on a curved surface.
    Veltchev I; Price R; Chen X; Howell K; Meyer J; Ma CM
    Med Phys; 2019 Apr; 46(4):1905-1913. PubMed ID: 30734318
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Comparison of a centered 32P source wire system with a noncentered 90Sr/Y brachytherapy system for intracoronary beta-radiation following PCI of diffuse in-stent restenosis.
    Haase J; von Neumann-Cosel P; Damm M; Hofmann M; Störger H; Isner D; Bergmann M; Piancatelli C; Schächinger V; Schwarz F
    Cardiovasc Revasc Med; 2005; 6(4):140-6. PubMed ID: 16326374
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Accuracy assessment of the superposition principle for evaluating dose distributions of elongated and curved 103Pd and 192Ir brachytherapy sources.
    Bannon EA; Yang Y; Rivard MJ
    Med Phys; 2011 Jun; 38(6):2957-63. PubMed ID: 21815369
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Monte Carlo calculation of dosimetry parameters for the IR08-103Pd brachytherapy source.
    Saidi P; Sadeghi M; Shirazi A; Tenreiro C
    Med Phys; 2010 Jun; 37(6):2509-15. PubMed ID: 20632562
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Dosimetric impact of an air passage on intraluminal brachytherapy for bronchus cancer.
    Okamoto H; Wakita A; Nakamura S; Nishioka S; Aikawa A; Kato T; Abe Y; Kobayashi K; Inaba K; Murakami N; Itami J
    J Radiat Res; 2016 Nov; 57(6):637-645. PubMed ID: 27605630
    [TBL] [Abstract][Full Text] [Related]  

  • 60. A dosimetric comparison of 169Yb and 192Ir for HDR brachytherapy of the breast, accounting for the effect of finite patient dimensions and tissue inhomogeneities.
    Lymperopoulou G; Papagiannis P; Angelopoulos A; Karaiskos P; Georgiou E; Baltas D
    Med Phys; 2006 Dec; 33(12):4583-9. PubMed ID: 17278810
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.