These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

130 related articles for article (PubMed ID: 10829644)

  • 1. Ultrasonic non-destructive testing of pieces of complex geometry with a flexible phased array transducer.
    Chatillon S; Cattiaux G; Serre M; Roy O
    Ultrasonics; 2000 Mar; 38(1-8):131-4. PubMed ID: 10829644
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Control of the ultrasonic beam transmitted through an irregular profile using a smart flexible transducer: modelling and application.
    Roy O; Mahaut S; Casula O
    Ultrasonics; 2002 May; 40(1-8):243-6. PubMed ID: 12159940
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Development of phased array techniques to improve characterization of defect located in a component of complex geometry.
    Mahaut S; Roy O; Beroni C; Rotter B
    Ultrasonics; 2002 May; 40(1-8):165-9. PubMed ID: 12159925
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Control of complex components with Smart Flexible Phased Arrays.
    Casula O; Poidevin C; Cattiaux G; Dumas P
    Ultrasonics; 2006 Dec; 44 Suppl 1():e647-51. PubMed ID: 17070565
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Acoustic Field of a Linear Phased Array: A Simulation Study of Ultrasonic Circular Tube Material.
    Xiao Z; Guo Y; Geng L; Wu J; Zhang F; Wang W; Liu Y
    Sensors (Basel); 2019 May; 19(10):. PubMed ID: 31121876
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Validation of Novel Ultrasonic Phased Array Borehole Probe by Using Simulation and Measurement.
    Prabhakara P; Mielentz F; Stolpe H; Behrens M; Lay V; Niederleithinger E
    Sensors (Basel); 2022 Dec; 22(24):. PubMed ID: 36560191
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Two-dimensional analytic modeling of acoustic diffraction for ultrasonic beam steering by phased array transducers.
    Wang T; Zhang C; Aleksov A; Salama I; Kar A
    Ultrasonics; 2017 Apr; 76():35-43. PubMed ID: 28040628
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Transient elastodynamic model for beam defect interaction: application to non-destructive testing.
    Raillon R; Lecoeur-Taibi I
    Ultrasonics; 2000 Mar; 38(1-8):527-30. PubMed ID: 10829719
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The Use of Flexible Ultrasound Transducers for the Detection of Laser-Induced Guided Waves on Curved Surfaces at Elevated Temperatures.
    Wu TC; Kobayashi M; Tanabe M; Yang CH
    Sensors (Basel); 2017 Jun; 17(6):. PubMed ID: 28587215
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A Fast Method to Calculate the Spatial Impulse Response for 1-D Linear Ultrasonic Phased Array Transducers.
    Zou C; Sun Z; Cai D; Muhammad S; Zhang W; Chen Q
    Sensors (Basel); 2016 Nov; 16(11):. PubMed ID: 27834799
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Modeling of phased array transducers.
    Ahmad R; Kundu T; Placko D
    J Acoust Soc Am; 2005 Apr; 117(4 Pt 1):1762-76. PubMed ID: 15898623
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A parametric study of ultrasonic beam profiles for a linear phased array transducer.
    Lee JH; Choi SW
    IEEE Trans Ultrason Ferroelectr Freq Control; 2000; 47(3):644-50. PubMed ID: 18238592
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Modeling the radiation of ultrasonic phased-array transducers with Gaussian beams.
    Huang R; Schmerr LW; Sedov A
    IEEE Trans Ultrason Ferroelectr Freq Control; 2008 Dec; 55(12):2692-702. PubMed ID: 19126493
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Simulation study of a chaotic cavity transducer based virtual phased array used for focusing in the bulk of a solid material.
    Delrue S; Van Den Abeele K; Bou Matar O
    Ultrasonics; 2016 Apr; 67():151-159. PubMed ID: 26845370
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Acoustic field prediction for a single planar continuous-wave source using an equivalent phased array method.
    Fan X; Moros EG; Straube WL
    J Acoust Soc Am; 1997 Nov; 102(5 Pt 1):2734-41. PubMed ID: 9373969
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Improved intercostal HIFU ablation using a phased array transducer based on Fermat's spiral and Voronoi tessellation: A numerical evaluation.
    Ramaekers P; Ries M; Moonen CT; de Greef M
    Med Phys; 2017 Mar; 44(3):1071-1088. PubMed ID: 28058731
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Development of Low-Frequency Phased Array for Imaging Defects in Concrete Structures.
    Ohara Y; Kikuchi K; Tsuji T; Mihara T
    Sensors (Basel); 2021 Oct; 21(21):. PubMed ID: 34770316
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Sound field calculations for an ultrasonic linear phased array with a spherical liquid lens.
    Yoon YJ; Benkeser PJ
    IEEE Trans Ultrason Ferroelectr Freq Control; 1992; 39(2):268-72. PubMed ID: 18263146
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Recent Advances in Flexible Ultrasonic Transducers: From Materials Optimization to Imaging Applications.
    Ren D; Yin Y; Li C; Chen R; Shi J
    Micromachines (Basel); 2023 Jan; 14(1):. PubMed ID: 36677187
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Reflection at a liquid-solid interface of a transient ultrasonic field radiated by a linear phased array transducer.
    Maghlaoui N; Belgroune D; Ourak M; Djelouah H
    Ultrasonics; 2016 Sep; 71():98-105. PubMed ID: 27290651
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.