273 related articles for article (PubMed ID: 10847187)
1. Electrical impedance tomography (EIT) in applications related to lung and ventilation: a review of experimental and clinical activities.
Frerichs I
Physiol Meas; 2000 May; 21(2):R1-21. PubMed ID: 10847187
[TBL] [Abstract][Full Text] [Related]
2. Electrical impedance tomography: functional lung imaging on its way to clinical practice?
Gong B; Krueger-Ziolek S; Moeller K; Schullcke B; Zhao Z
Expert Rev Respir Med; 2015; 9(6):721-37. PubMed ID: 26488464
[TBL] [Abstract][Full Text] [Related]
3. Impedance tomography as a new monitoring technique.
Muders T; Luepschen H; Putensen C
Curr Opin Crit Care; 2010 Jun; 16(3):269-75. PubMed ID: 20445445
[TBL] [Abstract][Full Text] [Related]
4. Electrical impedance tomography for lung ventilation monitoring of the dog.
Gloning S; Pieper K; Zoellner M; Meyer-Lindenberg A
Tierarztl Prax Ausg K Kleintiere Heimtiere; 2017 Feb; 45(1):15-21. PubMed ID: 28094413
[TBL] [Abstract][Full Text] [Related]
5. Coupling of EIT with computational lung modeling for predicting patient-specific ventilatory responses.
Roth CJ; Becher T; Frerichs I; Weiler N; Wall WA
J Appl Physiol (1985); 2017 Apr; 122(4):855-867. PubMed ID: 27932671
[TBL] [Abstract][Full Text] [Related]
6. Electrical impedance tomography imaging of the cardiopulmonary system.
Frerichs I; Becher T; Weiler N
Curr Opin Crit Care; 2014 Jun; 20(3):323-32. PubMed ID: 24739268
[TBL] [Abstract][Full Text] [Related]
7. Changes in the thoracic impedance distribution under different ventilatory conditions.
Hahn G; Sipinková I; Baisch F; Hellige G
Physiol Meas; 1995 Aug; 16(3 Suppl A):A161-73. PubMed ID: 8528115
[TBL] [Abstract][Full Text] [Related]
8. Local mechanics of the lung tissue determined by functional EIT.
Hahn G; Frerichs I; Kleyer M; Hellige G
Physiol Meas; 1996 Nov; 17 Suppl 4A():A159-66. PubMed ID: 9001614
[TBL] [Abstract][Full Text] [Related]
9. Monitoring of regional lung ventilation using electrical impedance tomography.
Vasques F; Sanderson B; Barrett NA; Camporota L
Minerva Anestesiol; 2019 Nov; 85(11):1231-1241. PubMed ID: 30945516
[TBL] [Abstract][Full Text] [Related]
10. Assessing regional lung mechanics by combining electrical impedance tomography and forced oscillation technique.
Ngo C; Spagnesi S; Munoz C; Lehmann S; Vollmer T; Misgeld B; Leonhardt S
Biomed Tech (Berl); 2018 Nov; 63(6):673-681. PubMed ID: 28850542
[TBL] [Abstract][Full Text] [Related]
11. Regional ventilation distribution determined by electrical impedance tomography: reproducibility and effects of posture and chest plane.
Reifferscheid F; Elke G; Pulletz S; Gawelczyk B; Lautenschläger I; Steinfath M; Weiler N; Frerichs I
Respirology; 2011 Apr; 16(3):523-31. PubMed ID: 21261780
[TBL] [Abstract][Full Text] [Related]
12. Thoracic electrical impedance tomographic measurements during volume controlled ventilation-effects of tidal volume and positive end-expiratory pressure.
Frerichs I; Hahn G; Hellige G
IEEE Trans Med Imaging; 1999 Sep; 18(9):764-73. PubMed ID: 10571381
[TBL] [Abstract][Full Text] [Related]
13. Gravity-dependent phenomena in lung ventilation determined by functional EIT.
Frerichs I; Hahn G; Hellige G
Physiol Meas; 1996 Nov; 17 Suppl 4A():A149-57. PubMed ID: 9001613
[TBL] [Abstract][Full Text] [Related]
14. Electrical impedance tomography in monitoring experimental lung injury.
Frerichs I; Hahn G; Schröder T; Hellige G
Intensive Care Med; 1998 Aug; 24(8):829-36. PubMed ID: 9757928
[TBL] [Abstract][Full Text] [Related]
15. Principles of electrical impedance tomography and its clinical application.
Bodenstein M; David M; Markstaller K
Crit Care Med; 2009 Feb; 37(2):713-24. PubMed ID: 19114889
[TBL] [Abstract][Full Text] [Related]
16. Measurement of relative lung perfusion with electrical impedance and positron emission tomography: an experimental comparative study in pigs.
Bluth T; Kiss T; Kircher M; Braune A; Bozsak C; Huhle R; Scharffenberg M; Herzog M; Roegner J; Herzog P; Vivona L; Millone M; Dössel O; Andreeff M; Koch T; Kotzerke J; Stender B; Gama de Abreu M
Br J Anaesth; 2019 Aug; 123(2):246-254. PubMed ID: 31160064
[TBL] [Abstract][Full Text] [Related]
17. System introduction and evaluation of the first Chinese chest EIT device for ICU applications.
Qu SY; Dai M; Wu S; Lv ZR; Ti XY; Fu F
Sci Rep; 2021 Sep; 11(1):19273. PubMed ID: 34588556
[TBL] [Abstract][Full Text] [Related]
18. Electrical impedance tomography: potentials and pitfalls.
Lundin S; Stenqvist O
Curr Opin Crit Care; 2012 Feb; 18(1):35-41. PubMed ID: 22201705
[TBL] [Abstract][Full Text] [Related]
19. Monitoring perioperative changes in distribution of pulmonary ventilation by functional electrical impedance tomography.
Frerichs I; Hahn G; Golisch W; Kurpitz M; Burchardi H; Hellige G
Acta Anaesthesiol Scand; 1998 Jul; 42(6):721-6. PubMed ID: 9689281
[TBL] [Abstract][Full Text] [Related]
20. Redistribution of pulmonary ventilation after lung surgery detected with electrical impedance tomography.
Lehmann M; Oehler B; Zuber J; Malzahn U; Walles T; Muellenbach RM; Roewer N; Kredel M
Acta Anaesthesiol Scand; 2020 Apr; 64(4):517-525. PubMed ID: 31830306
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]