BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

169 related articles for article (PubMed ID: 10852195)

  • 1. False alarms in very low birthweight infants: comparison between three intensive care monitoring systems.
    Ahlborn V; Bohnhorst B; Peter CS; Poets CF
    Acta Paediatr; 2000 May; 89(5):571-6. PubMed ID: 10852195
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparison between pulse oximetry and transthoracic impedance alarm traces during home monitoring.
    Nassi N; Piumelli R; Lombardi E; Landini L; Donzelli G; de Martino M
    Arch Dis Child; 2008 Feb; 93(2):126-32. PubMed ID: 17893118
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Improved Filtering of Pulse Oximeter Monitoring Alarms in the Neonatal ICU: Bedside Significance.
    Stefanescu BM; O'Shea TM; Haury F; Carlo WA; Slaughter JC
    Respir Care; 2016 Jan; 61(1):85-9. PubMed ID: 26508772
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Alarms, oxygen saturations, and SpO2 averaging time in the NICU.
    McClure C; Jang SY; Fairchild K
    J Neonatal Perinatal Med; 2016; 9(4):357-362. PubMed ID: 27834782
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Influence of pulse oximeter settings on the frequency of alarms and detection of hypoxemia: Theoretical effects of artifact rejection, alarm delay, averaging, median filtering or a lower setting of the alarm limit.
    Rheineck-Leyssius AT; Kalkman CJ
    J Clin Monit Comput; 1998 Apr; 14(3):151-6. PubMed ID: 9676861
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Pulse oximeters' reliability in detecting hypoxemia and bradycardia: comparison between a conventional and two new generation oximeters.
    Bohnhorst B; Peter CS; Poets CF
    Crit Care Med; 2000 May; 28(5):1565-8. PubMed ID: 10834712
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Postanesthesia monitoring revisited: frequency of true and false alarms from different monitoring devices.
    Wiklund L; Hök B; Ståhl K; Jordeby-Jönsson A
    J Clin Anesth; 1994; 6(3):182-8. PubMed ID: 8060626
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Advanced pulse oximeter signal processing technology compared to simple averaging. I. Effect on frequency of alarms in the operating room.
    Rheineck-Leyssius AT; Kalkman CJ
    J Clin Anesth; 1999 May; 11(3):192-5. PubMed ID: 10434213
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Clinical use of new-generation pulse oximeters in the neonatal intensive care unit.
    Workie FA; Rais-Bahrami K; Short BL
    Am J Perinatol; 2005 Oct; 22(7):357-60. PubMed ID: 16215921
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Advanced pulse oximeter signal processing technology compared to simple averaging. II. Effect on frequency of alarms in the postanesthesia care unit.
    Rheineck-Leyssius AT; Kalkman CJ
    J Clin Anesth; 1999 May; 11(3):196-200. PubMed ID: 10434214
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Reducing Alarm Fatigue in Two Neonatal Intensive Care Units through a Quality Improvement Collaboration.
    Johnson KR; Hagadorn JI; Sink DW
    Am J Perinatol; 2018 Nov; 35(13):1311-1318. PubMed ID: 29783270
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Poor prognosis for existing monitors in the intensive care unit.
    Tsien CL; Fackler JC
    Crit Care Med; 1997 Apr; 25(4):614-9. PubMed ID: 9142025
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Reducing False Alarm Rates in Neonatal Intensive Care: A New Machine Learning Approach.
    Ostojic D; Guglielmini S; Moser V; Fauchère JC; Bucher HU; Bassler D; Wolf M; Kleiser S; Scholkmann F; Karen T
    Adv Exp Med Biol; 2020; 1232():285-290. PubMed ID: 31893422
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Epidemiology of patient monitoring alarms in the neonatal intensive care unit.
    Li T; Matsushima M; Timpson W; Young S; Miedema D; Gupta M; Heldt T
    J Perinatol; 2018 Aug; 38(8):1030-1038. PubMed ID: 29740183
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The heuristics of nurse responsiveness to critical patient monitor and ventilator alarms in a private room neonatal intensive care unit.
    Joshi R; Mortel HV; Feijs L; Andriessen P; Pul CV
    PLoS One; 2017; 12(10):e0184567. PubMed ID: 28981515
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Safe patient monitoring is challenging but still feasible in a neonatal intensive care unit with single family rooms.
    van Pul C; V D Mortel HP; V D Bogaart JJ; Mohns T; Andriessen P
    Acta Paediatr; 2015 Jun; 104(6):e247-54. PubMed ID: 25619759
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Crying wolf: false alarms in a pediatric intensive care unit.
    Lawless ST
    Crit Care Med; 1994 Jun; 22(6):981-5. PubMed ID: 8205831
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Evaluation of two SpO
    Warakomska M; Bachman TE; Wilinska M
    BMC Pediatr; 2019 May; 19(1):142. PubMed ID: 31060536
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Multicentric study of monitoring alarms in the adult intensive care unit (ICU): a descriptive analysis.
    Chambrin MC; Ravaux P; Calvelo-Aros D; Jaborska A; Chopin C; Boniface B
    Intensive Care Med; 1999 Dec; 25(12):1360-6. PubMed ID: 10660842
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Prolonged, documented home-monitoring of oxygenation in infants and children.
    Gélinas JF; Davis GM; Arlegui C; Côté A
    Pediatr Pulmonol; 2008 Mar; 43(3):288-96. PubMed ID: 18219691
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.