These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

101 related articles for article (PubMed ID: 10878278)

  • 1. A 'minimum-wear-and-tear' meshwork for the iris.
    Wyatt HJ
    Vision Res; 2000; 40(16):2167-76. PubMed ID: 10878278
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Iris mechanics. II. Influence of pupil size on details of iris structure.
    Newsome DA; Loewenfeld IE
    Am J Ophthalmol; 1971 Feb; 71(2):553-73. PubMed ID: 5547536
    [No Abstract]   [Full Text] [Related]  

  • 3. Lattice-like collagen fiber meshwork in the iris stroma of the cat: a possible mechanism to generate the tension directed towards the iris root which is required for pupillary dilatation in the sympathectomized eye.
    Sakuraba M; Yun S; Ichinohe N; Yonekura H; Shoumura K
    Kaibogaku Zasshi; 1999 Oct; 74(5):577-86. PubMed ID: 10565115
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The fine structure of extracellular material in the pectinate ligament (trabecular meshwork) of the human iris.
    LEESON TS; SPEAKMAN JS
    Acta Anat (Basel); 1961; 46():363-79. PubMed ID: 14463630
    [No Abstract]   [Full Text] [Related]  

  • 5. Pupil mnemonics.
    Ing EB; Ing TG
    Can J Ophthalmol; 1995 Oct; 30(6):319-20. PubMed ID: 8574980
    [No Abstract]   [Full Text] [Related]  

  • 6. The physiologic characteristics of relative pupillary block.
    Anderson DR; Jin JC; Wright MM
    Am J Ophthalmol; 1991 Mar; 111(3):344-50. PubMed ID: 2000905
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Iris movement mediates pupillary membrane regression].
    Morizane Y
    Nippon Ganka Gakkai Zasshi; 2007 Nov; 111(11):872-80. PubMed ID: 18051817
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A new criterion to distinguish stochastic and deterministic time series with the PoincarĂ© section and fractal dimension.
    Golestani A; Jahed Motlagh MR; Ahmadian K; Omidvarnia AH; Mozayani N
    Chaos; 2009 Mar; 19(1):013137. PubMed ID: 19335001
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [The anterior stroma layer of the iris as an example for the biomorphosis of collagenous connective tissue].
    Purtscher E
    Klin Monbl Augenheilkd; 1972 Mar; 160(3):296-9. PubMed ID: 4260241
    [No Abstract]   [Full Text] [Related]  

  • 10. Vertical Pupil in a Lemon Shark.
    Schwab IR; Heidemann DG
    Ophthalmology; 2021 Feb; 128(2):316. PubMed ID: 33485479
    [No Abstract]   [Full Text] [Related]  

  • 11. [Iris structure of cat and dog in their functional aspects].
    Hager G
    Wien Tierarztl Monatsschr; 1966 Nov; 53(11):715-24. PubMed ID: 6013619
    [No Abstract]   [Full Text] [Related]  

  • 12. Automated Detection of Iris Furrows and their Influence on Dynamic Iris Volume Change.
    Chua J; Thakku SG; Pham TH; Lee R; Tun TA; Nongpiur ME; Tan MCL; Wong TY; Quah JHM; Aung T; Girard MJA; Cheng CY
    Sci Rep; 2017 Dec; 7(1):17894. PubMed ID: 29263345
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Iris Crypts Influence Dynamic Changes of Iris Volume.
    Chua J; Thakku SG; Tun TA; Nongpiur ME; Tan MC; Girard MJ; Wong TY; Quah JH; Aung T; Cheng CY
    Ophthalmology; 2016 Oct; 123(10):2077-84. PubMed ID: 27521171
    [TBL] [Abstract][Full Text] [Related]  

  • 14. J-shaped stress-strain diagram of collagen fibers: Frame tension of triangulated surfaces with fixed boundaries.
    Takano Y; Koibuchi H
    Phys Rev E; 2017 Apr; 95(4-1):042411. PubMed ID: 28505728
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Epigenetic randomness, complexity and singularity of human iris patterns.
    Daugman J; Downing C
    Proc Biol Sci; 2001 Aug; 268(1477):1737-40. PubMed ID: 11506688
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Iris-based medical analysis by geometric deformation features.
    Ma L; Zhang D; Li N; Cai Y; Zuo W; Wang K
    IEEE J Biomed Health Inform; 2013 Jan; 17(1):223-31. PubMed ID: 23144041
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Iris mechanics. I. Influence of pupil size on dynamics of pupillary movements.
    Loewenfeld IE; Newsome DA
    Am J Ophthalmol; 1971 Jan; 71(1 Pt 2):347-62. PubMed ID: 5100474
    [No Abstract]   [Full Text] [Related]  

  • 18. Reverse pupillary block slows iris contour recovery from corneoscleral indentation.
    Amini R; Barocas VH
    J Biomech Eng; 2010 Jul; 132(7):071010. PubMed ID: 20590288
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Anterior chamber angle imaging with swept-source optical coherence tomography: an investigation on variability of angle measurement.
    Liu S; Yu M; Ye C; Lam DS; Leung CK
    Invest Ophthalmol Vis Sci; 2011 Nov; 52(12):8598-603. PubMed ID: 21948547
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A physical analysis of the factors that determine the contour of the iris.
    Kalenak JW
    Am J Ophthalmol; 1991 Aug; 112(2):219-21. PubMed ID: 1867314
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 6.