143 related articles for article (PubMed ID: 10882668)
1. Use of synthetic cardiolipin and lecithin in the antigen used by the venereal disease research laboratory test for serodiagnosis of syphilis.
Castro AR; Morrill WE; Shaw WA; Gale DC; Park MM; Peregrino-Ferreira LA; Bazzo ML; Pope V
Clin Diagn Lab Immunol; 2000 Jul; 7(4):658-61. PubMed ID: 10882668
[TBL] [Abstract][Full Text] [Related]
2. Enzyme-linked immunosorbent assay for detection of antibodies to the venereal disease research laboratory (VDRL) antigen in syphilis.
Pedersen NS; Orum O; Mouritsen S
J Clin Microbiol; 1987 Sep; 25(9):1711-6. PubMed ID: 3308951
[TBL] [Abstract][Full Text] [Related]
3. Pure phosphatides and the serodiagnosis of syphilis: relation of chemical structure to reactivity.
ALLEN RH; TONKS DB
Bull World Health Organ; 1958; 19(3):547-61. PubMed ID: 13596881
[TBL] [Abstract][Full Text] [Related]
4. Visuwell Reagin, a non-treponemal enzyme-linked immunosorbent assay for the serodiagnosis of syphilis.
White TJ; Fuller SA
J Clin Microbiol; 1989 Oct; 27(10):2300-4. PubMed ID: 2584380
[TBL] [Abstract][Full Text] [Related]
5. Use of synthetic, crystalline, L-alpha-dimyristoyl lecithin in cardiolipin antigens.
REYN A; BENTZON MW
Bull World Health Organ; 1956; 14(3):567-76. PubMed ID: 13342931
[TBL] [Abstract][Full Text] [Related]
6. The VDRL tube flocculation test; a microflocculation test for syphilis using cardiolipin-lecithin-cholesterol antigen.
VOGELSANG TM; HAALAND R
Br J Vener Dis; 1951 Jun; 27(2):52-8. PubMed ID: 14858839
[No Abstract] [Full Text] [Related]
7. The reagin screen test: a new reagin card test for syphilis.
March RW; Stiles GE
Sex Transm Dis; 1980; 7(2):66-70. PubMed ID: 7394697
[TBL] [Abstract][Full Text] [Related]
8. Toluidine red unheated serum test, a nontreponemal test for syphilis.
Pettit DE; Larsen SA; Harbec PS; Feeley JC; Parham CE; Cruce DD; Hambie EA; Perryman MW
J Clin Microbiol; 1983 Nov; 18(5):1141-5. PubMed ID: 6417160
[TBL] [Abstract][Full Text] [Related]
9. Enzyme-linked immunosorbent assay (ELISA) versus Venereal Disease Research Laboratory test (VDRL) and rapid plasma reagin test (RPR) for screening of syphilis in pregnant women.
Solaimalai D; Rathore S; Beck MM; Regi A; Yesudhason BL; Veeraraghavan B; Prakash JAJ
Int J Gynaecol Obstet; 2020 Jul; 150(1):103-107. PubMed ID: 32246772
[TBL] [Abstract][Full Text] [Related]
10. Whole-blood hemagglutination inhibition test for venereal disease research laboratory (VDRL) antibodies.
Meyer MP; Baughn RE
J Clin Microbiol; 2000 Sep; 38(9):3413-4. PubMed ID: 10970393
[TBL] [Abstract][Full Text] [Related]
11. Interlaboratory comparison of the toluidine red unheated serum test antigen preparation.
Parham CE; Pettit DE; Larsen SA; Hambie EA; Perryman MW; McGrew BE
J Clin Microbiol; 1984 Sep; 20(3):434-7. PubMed ID: 6386860
[TBL] [Abstract][Full Text] [Related]
12. Comparison of a new rapid plasma reagin card test with the standard rapid plasma reagin 18-mm circle card test and the venereal disease research laboratory slide test for serodiagnosis of syphilis.
Hambie EA; Larsen SA; Perryman MW; Pettit DE; Mullally RL; Whittington W
J Clin Microbiol; 1983 Feb; 17(2):249-54. PubMed ID: 6833479
[TBL] [Abstract][Full Text] [Related]
13. Role of the Venereal Disease Research Laboratory test in the detection of syphilis.
Diggory P
Br J Vener Dis; 1983 Feb; 59(1):8-10. PubMed ID: 6337682
[TBL] [Abstract][Full Text] [Related]
14. A comparison of nontreponemal tests in cerebrospinal fluid for neurosyphilis diagnosis: equivalent detection of specific antibodies.
Versiani I; Cabral-Castro MJ; Puccioni-Sohler M
Arq Neuropsiquiatr; 2019 Feb; 77(2):91-95. PubMed ID: 30810592
[TBL] [Abstract][Full Text] [Related]
15. Unheated serum reagin test as a quantitative test for syphilis.
Pettit DE; Larsen SA; Pope V; Perryman MW; Adams MR
J Clin Microbiol; 1982 Feb; 15(2):238-42. PubMed ID: 7068819
[TBL] [Abstract][Full Text] [Related]
16. Large liposome agglutination technique for the serological detection of syphilis.
Kung VT; Vollmer YP; Martin FJ
J Immunol Methods; 1986 Jun; 90(2):189-96. PubMed ID: 3722824
[TBL] [Abstract][Full Text] [Related]
17. Syphilis serology testing: a comparative study of Abbot Determine, Rapid Plasma Reagin (RPR) card test and Venereal Disease Research Laboratory (VDRL) methods.
Angue Y; Yauieb A; Mola G; Duke T; Amoa AB
P N G Med J; 2005; 48(3-4):168-73. PubMed ID: 17212063
[TBL] [Abstract][Full Text] [Related]
18. An evaluation of the relative sensitivities of the venereal disease research laboratory test and the Treponema pallidum particle agglutination test among patients diagnosed with primary syphilis.
Creegan L; Bauer HM; Samuel MC; Klausner J; Liska S; Bolan G
Sex Transm Dis; 2007 Dec; 34(12):1016-1018. PubMed ID: 18080352
[TBL] [Abstract][Full Text] [Related]
19. Evaluation of reagin screen, a new serological test for syphilis.
Dyckman JD; Wende RD; Gantenbein D; Williams RP
J Clin Microbiol; 1976 Aug; 4(2):145-50. PubMed ID: 787004
[TBL] [Abstract][Full Text] [Related]
20. The effect of cholesterol on the morphology and reactivity of the mixture of lipids used in syphilis serology.
Orum O; Nielsen JR; Birch-Andersen A
APMIS; 1990 Jan; 98(1):9-18. PubMed ID: 2105737
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]