These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

208 related articles for article (PubMed ID: 1090895)

  • 21. Transcutaneous oxygen measurements: calibration analysis and electrode stabilization methods.
    Severinghaus JW; Peabody JL; Thunström AM; Stafford M
    Acta Anaesthesiol Scand Suppl; 1978; 70():180-2. PubMed ID: 283662
    [No Abstract]   [Full Text] [Related]  

  • 22. Transcutaneous determination of arterial oxygen tension.
    Fenner A; Müller R; Busse HG; Junge M; Wolfsdorf J
    Pediatrics; 1975 Feb; 55(2):224-31. PubMed ID: 1118209
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Clinical experiences of transcutaneous PO2 monitoring in high risk newborn infants.
    Oda Y
    Birth Defects Orig Artic Ser; 1979; 15(4):371-3. PubMed ID: 534719
    [No Abstract]   [Full Text] [Related]  

  • 24. Continuous comparison of transcutaneous and arterial oxygen tension in newborn infants with respiratory illnesses.
    Le Souëf PN; Morgan AK; Soutter LP; Reynolds EO; Parker D
    Acta Anaesthesiol Scand Suppl; 1978; 68():91-7. PubMed ID: 279208
    [TBL] [Abstract][Full Text] [Related]  

  • 25. The influence of different electrode temperatures on the recorded transcutaneous Po2 level.
    Löfgren O; Jacobson L
    Pediatrics; 1979 Dec; 64(6):892-7. PubMed ID: 514717
    [TBL] [Abstract][Full Text] [Related]  

  • 26. [The hyperoxia test using transcutaneous oxygen tension monitoring in critically ill newborn infants].
    Nekvasil R; Stejskal J; Muchová M
    Cesk Pediatr; 1982 Apr; 37(4):185-91. PubMed ID: 7046965
    [No Abstract]   [Full Text] [Related]  

  • 27. [The oxymeter, a new device for the continuous transcutaneous measurement of the arterial oxygen partial pressure].
    Reineke H; Fiesel G; Frankenberger H; Ahnefeld FW
    Anaesthesist; 1977 Jul; 26(7):361-8. PubMed ID: 889072
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Transcutaneous PO2 monitoring in routine management of infants and children with cardiorespiratory problems.
    Huch R; Huch A; Albani M; Gabriel M; Schulte FJ; Wolf H; Rupprath G; Emmrich P; Stechele U; Duc G; Bucher H
    Pediatrics; 1976 May; 57(5):681-90. PubMed ID: 940708
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Effect of electrode temperature and in vivo calibration on accuracy of transcutaneous estimation of arterial oxygen tension in infants.
    Pollitzer MJ; Whitehead MD; Reynolds EO; Delpy D
    Pediatrics; 1980 Mar; 65(3):515-22. PubMed ID: 7360538
    [No Abstract]   [Full Text] [Related]  

  • 30. [Transcutaneous measurement of partial blood oxygen pressure].
    Toyoshima E; Suma K
    Rinsho Byori; 1983 Oct; Spec No 57():43-57. PubMed ID: 6371321
    [No Abstract]   [Full Text] [Related]  

  • 31. Transcutaneous measurement of partial pressure of oxygen and carbon dioxide.
    Franklin ML
    Respir Care Clin N Am; 1995 Sep; 1(1):119-31. PubMed ID: 9390854
    [TBL] [Abstract][Full Text] [Related]  

  • 32. A modified tcPO2 electrode: a new concept using diathermy.
    Huch A; Meinzer K; Seiler D; Fallenstein F; Lübbers DW; Huch R
    Birth Defects Orig Artic Ser; 1979; 15(4):103-7. PubMed ID: 534688
    [No Abstract]   [Full Text] [Related]  

  • 33. [Conjunctival oxygen tension. Testing oxygen tension measurement of the conjunctiva].
    Gellett SC; Hjortdal VE; Kirkegaard L; Sørensen T; Gottrup F
    Ugeskr Laeger; 1990 Jul; 152(28):2050-2. PubMed ID: 2368204
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Preliminary data on the clinical use of a self-constructed transcutaneous PO2 electrode during labor.
    Wladimiroff JW; von 't Hof DB; Verhoeff A; Drogendijk AC; Jansen KT
    Birth Defects Orig Artic Ser; 1979; 15(4):245-8. PubMed ID: 534703
    [No Abstract]   [Full Text] [Related]  

  • 35. Measurement of heated skin O2 diffusion conductance and PO2 sensor induced O2 gradient.
    Eberhard P; Severinghaus JW
    Acta Anaesthesiol Scand Suppl; 1978; 68():1-3. PubMed ID: 279189
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Continuous arterial and venous blood gas monitoring during cardiopulmonary bypass.
    Mark JB; FitzGerald D; Fenton T; Fosberg AM; Camann W; Maffeo N; Winkelman J
    J Thorac Cardiovasc Surg; 1991 Sep; 102(3):431-9. PubMed ID: 1908928
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Skin craters--a complication of transcutaneous oxygen monitoring.
    Golden SM
    Pediatrics; 1981 Apr; 67(4):514-6. PubMed ID: 7254973
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Intraarterial vs. transcutaneous PO2 monitoring in newborn infants. Indications and limitations.
    Riegel KP; Versmold HT
    Biotelem Patient Monit; 1979; 6(1-2):32-43. PubMed ID: 486723
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Ductal shunt in premature infants observed by tcPO2 measurements.
    Yamanouchi I; Igarashi I
    Birth Defects Orig Artic Ser; 1979; 15(4):323-40. PubMed ID: 534712
    [No Abstract]   [Full Text] [Related]  

  • 40. Letter: Is transcutaneous Po2 reliable for arterial oxygen monitoring in newborn infants?
    Duc G; Bucher HU; Micheli JL; Johanson BA
    Pediatrics; 1975 Apr; 55(4):566-7. PubMed ID: 1128970
    [No Abstract]   [Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 11.