BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

158 related articles for article (PubMed ID: 10909922)

  • 1. Noise characterization of block-iterative reconstruction algorithms: I. Theory.
    Soares EJ; Byrne CL; Glick SJ
    IEEE Trans Med Imaging; 2000 Apr; 19(4):261-70. PubMed ID: 10909922
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Noise characterization of block-iterative reconstruction algorithms: II. Monte Carlo simulations.
    Soares EJ; Glick SJ; Hoppin JW
    IEEE Trans Med Imaging; 2005 Jan; 24(1):112-21. PubMed ID: 15638190
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Block-iterative techniques for fast 4D reconstruction using a priori motion models in gated cardiac SPECT.
    Lalush DS; Tsui BM
    Phys Med Biol; 1998 Apr; 43(4):875-86. PubMed ID: 9572511
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Noise analysis of MAP-EM algorithms for emission tomography.
    Wang W; Gindi G
    Phys Med Biol; 1997 Nov; 42(11):2215-32. PubMed ID: 9394408
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Reducing the influence of the partial volume effect on SPECT activity quantitation with 3D modelling of spatial resolution in iterative reconstruction.
    Pretorius PH; King MA; Pan TS; de Vries DJ; Glick SJ; Byrne CL
    Phys Med Biol; 1998 Feb; 43(2):407-20. PubMed ID: 9509535
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Accelerating the EMML algorithm and related iterative algorithms by rescaled block-iterative methods.
    Byrne CL
    IEEE Trans Image Process; 1998; 7(1):100-9. PubMed ID: 18267383
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Convergence study of an accelerated ML-EM algorithm using bigger step size.
    Hwang D; Zeng GL
    Phys Med Biol; 2006 Jan; 51(2):237-52. PubMed ID: 16394336
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Task-based evaluation of a 4D MAP-RBI-EM image reconstruction method for gated myocardial perfusion SPECT using a human observer study.
    Lee TS; Higuchi T; Lautamäki R; Bengel FM; Tsui BM
    Phys Med Biol; 2015 Sep; 60(17):6789-809. PubMed ID: 26301337
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Noise propagation for iterative penalized-likelihood image reconstruction based on Fisher information.
    Li Y
    Phys Med Biol; 2011 Feb; 56(4):1083-103. PubMed ID: 21263172
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Accelerated image reconstruction using ordered subsets of projection data.
    Hudson HM; Larkin RS
    IEEE Trans Med Imaging; 1994; 13(4):601-9. PubMed ID: 18218538
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Likelihood maximization for list-mode emission tomographic image reconstruction.
    Byrne C
    IEEE Trans Med Imaging; 2001 Oct; 20(10):1084-92. PubMed ID: 11686443
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Improved iterative reconstruction method for Compton imaging using median filter.
    Sakai M; Parajuli RK; Kubota Y; Kubo N; Kikuchi M; Arakawa K; Nakano T
    PLoS One; 2020; 15(3):e0229366. PubMed ID: 32142552
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Performance of ordered-subset reconstruction algorithms under conditions of extreme attenuation and truncation in myocardial SPECT.
    Lalush DS; Tsui BM
    J Nucl Med; 2000 Apr; 41(4):737-44. PubMed ID: 10768577
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparison of a noise-weighted filtered backprojection algorithm with the Standard MLEM algorithm for poisson noise.
    Zeng GL
    J Nucl Med Technol; 2013 Dec; 41(4):283-8. PubMed ID: 24159012
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Noise properties of the EM algorithm: II. Monte Carlo simulations.
    Wilson DW; Tsui BM; Barrett HH
    Phys Med Biol; 1994 May; 39(5):847-71. PubMed ID: 15552089
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Noise properties of the EM algorithm: I. Theory.
    Barrett HH; Wilson DW; Tsui BM
    Phys Med Biol; 1994 May; 39(5):833-46. PubMed ID: 15552088
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Dual matrix ordered subsets reconstruction for accelerated 3D scatter compensation in single-photon emission tomography.
    Kamphuis C; Beekman FJ; van Rijk PP; Viergever MA
    Eur J Nucl Med; 1998 Jan; 25(1):8-18. PubMed ID: 9396869
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Subsets and overrelaxation in iterative image reconstruction.
    Schmidlin P; Bellemann ME; Brix G
    Phys Med Biol; 1999 May; 44(5):1385-96. PubMed ID: 10368026
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Similarity-regulation of OS-EM for accelerated SPECT reconstruction.
    Vaissier PE; Beekman FJ; Goorden MC
    Phys Med Biol; 2016 Jun; 61(11):4300-15. PubMed ID: 27206135
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A fast image reconstruction algorithm based on penalized-likelihood estimate.
    Sheng J; Ying L
    Med Eng Phys; 2005 Oct; 27(8):679-86. PubMed ID: 16139765
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.