BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

144 related articles for article (PubMed ID: 1091773)

  • 1. [Additional gadget for new techniques of artifical respiration with the Bennett repirator PR 2, particulary suitable for use in children (author's transl)].
    Lang VO
    Klin Padiatr; 1975 Jan; 187(1):30-6. PubMed ID: 1091773
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Easy alteration of the PEEP-system to CPAP by using exclusively original bird parts (author's transl)].
    Borst RH; Wolf H
    Anaesthesist; 1977 Nov; 26(11):633-6. PubMed ID: 339775
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [New PEEP device--application of PEEP and CPAP during manually operated ventilation (author's transl)].
    Dick W; Milewski P; Traub E
    Anaesthesist; 1977 Nov; 26(11):631-2. PubMed ID: 339774
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Manual artificial respiration of premature and newborn infants and children. A simple, universal and safe method with a modified Ambu-respirator].
    Babeş VT
    Anasthesiol Intensivmed Prax; 1974; 9(1):67-70. PubMed ID: 4534337
    [No Abstract]   [Full Text] [Related]  

  • 5. [Artificial ventilation of prematures and new bornes with the bennett pr-2 (author's transl)].
    Voigt E
    Prakt Anaesth; 1977 Jun; 12(3):222-7. PubMed ID: 335379
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [A simple self prepared IMV system using original parts of Bird including alternative ventilation under CPAP and PEEP (author's transl)].
    Stehle R; Borst RH; Schielke S
    Anaesthesist; 1979 Apr; 28(4):186-90. PubMed ID: 373496
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [H.R.P.-System 2000: a new universally applicable ventilation system for single or limited multiple use with high bacteriologic-hygienical safety (author's transl)].
    Lang VO
    Anaesthesist; 1979 Oct; 28(10):474-83. PubMed ID: 294155
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Manual respiration of premature and newborn infants and children. A simple, universal and safe method with a modified Ambu-respirator].
    Lang VO
    Anasthesiol Intensivmed Prax; 1974; 9(1):67-70. PubMed ID: 4533881
    [No Abstract]   [Full Text] [Related]  

  • 9. [A new respiratory care, adaptive assisted ventilation (AAV) --especially, about the weaning from respirator in the patient who cannot by weaned by IMV (author's transl)].
    Hino T; Wada J
    Kyobu Geka; 1981; 34(1):5-14. PubMed ID: 6936568
    [No Abstract]   [Full Text] [Related]  

  • 10. A modification of the Laerdal infant resuscitator for the simple and safe delivery of CPAP and PEEP.
    Bumstead D
    Respir Care; 1984 Mar; 29(3):270-2. PubMed ID: 10315536
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The impact of imposed expiratory resistance in neonatal mechanical ventilation: a laboratory evaluation.
    DiBlasi RM; Salyer JW; Zignego JC; Redding GJ; Richardson CP
    Respir Care; 2008 Nov; 53(11):1450-60. PubMed ID: 18957147
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Application of prolonged artifical ventilation in treatment of respiratory insufficiency in newborns (author's transl)].
    Kuś M
    Przegl Lek; 1973; 30(8):673-8. PubMed ID: 4585492
    [No Abstract]   [Full Text] [Related]  

  • 13. [A new "oxygen injector" technique for automated ventilation during laryngoscopy and/or bronchoscopy in infants and children (author's transl)].
    Mantel K; Butenandt I
    Med Klin; 1974 Nov; 69(44):1797-801. PubMed ID: 4531541
    [No Abstract]   [Full Text] [Related]  

  • 14. [I.M.V.-ventilation-techniques. Special considerations and problems of their application (author's transl)].
    Lang VO
    Anaesthesist; 1979 Sep; 28(9):419-27. PubMed ID: 384843
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Control of respirator pressure and drainage of the anesthetic gases with Kuhn's device in pediatric anesthesia (author's transl)].
    Link J; Henneberg U; Hövener B
    Anaesthesist; 1976 Jun; 25(6):287-9. PubMed ID: 1066061
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [H.R.P.-J.M.V.-200. A device for the simple adoption of modern ventilation techniques with various, even old, mechanical ventilators (author's transl)].
    Lang VO
    Anaesthesist; 1979 Apr; 28(4):191-200. PubMed ID: 285625
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Automatic weaning from mechanical ventilation by the new respiratory management, adaptive assisted ventilation: (AAV), (I)--conception and clinical indication (author's transl)].
    Hino T; Ishii K; Iida Y; Kainuma Y; Tomino T; Hayashi H
    Nihon Kyobu Geka Gakkai Zasshi; 1978 Aug; 26(8):926-33. PubMed ID: 280596
    [No Abstract]   [Full Text] [Related]  

  • 18. [A simple method for increasing endexpiratory pressure in the Bird Mark 8 ventilator for infants (author's transl)].
    Schachinger H; Frank HD
    Prakt Anaesth; 1974 Feb; 9(1):55-7. PubMed ID: 4617215
    [No Abstract]   [Full Text] [Related]  

  • 19. [New methods and modes of operation of type PO artificial respirators].
    Gal'perin IuS; Gologorskiĭ VA; Kassil' VL; Iurevich VM
    Med Tekh; 1983; (6):36-9. PubMed ID: 6363869
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Simple, exact separation of in- and expired gas during mechanical ventilation (author's transl)].
    Stokke T; Burchardi H
    Anaesthesist; 1982 Jun; 31(6):293-4. PubMed ID: 7051888
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.