These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

95 related articles for article (PubMed ID: 10919523)

  • 1. Changes in chest electrode impedance.
    Lateef F; Lim SH; Anantharaman V; Lim CS
    Am J Emerg Med; 2000 Jul; 18(4):381-4. PubMed ID: 10919523
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Chest impedance: characteristics of local patients.
    Lateef F; Lim SH; Anantharaman V; Lim CS
    Singapore Med J; 2000 Jul; 41(7):331-4. PubMed ID: 11026800
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Transthoracic impedance study with large self-adhesive electrodes in two conventional positions for defibrillation.
    Krasteva V; Matveev M; Mudrov N; Prokopova R
    Physiol Meas; 2006 Oct; 27(10):1009-22. PubMed ID: 16951460
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A finite-element study of the effects of electrode position on the measured impedance change in impedance cardiography.
    Wang Y; Haynor DR; Kim Y
    IEEE Trans Biomed Eng; 2001 Dec; 48(12):1390-401. PubMed ID: 11759920
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Accuracy of ECG electrode placement by emergency department clinicians.
    McCann K; Holdgate A; Mahammad R; Waddington A
    Emerg Med Australas; 2007 Oct; 19(5):442-8. PubMed ID: 17919217
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Disposable defibrillator electrodes.
    Ewy GA; Horan WJ; Ewy MD
    Heart Lung; 1977; 6(1):127-30. PubMed ID: 583893
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Optimal spacing of right ventricular bipolar catheter electrodes for detecting cardiac pumping by an automatic implantable defibrillator.
    Tacker WA; Bourland JD; Thacker JR; Babbs CF; Holmes HR; Fisher PG; Geddes LA
    Med Instrum; 1980; 14(1):27-9. PubMed ID: 7354733
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Time and frequency dependence of disposable ECG electrode-skin impedance.
    Olson WH; Schmincke DR; Henley BL
    Med Instrum; 1979; 13(5):269-72. PubMed ID: 502923
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Layperson positioning of defibrillation electrodes guided by pictorial instructions.
    Nurmi J; Castrén M
    Resuscitation; 2005 Feb; 64(2):177-80. PubMed ID: 15680526
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Measurement of cardiac output using Physio Flow with different positions of electrode placement.
    Tan KH; Lai FO; Hwang NC
    Singapore Med J; 2006 Nov; 47(11):967-70. PubMed ID: 17075665
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A comparison study of electrodes for neonate electrical impedance tomography.
    Rahal M; Khor JM; Demosthenous A; Tizzard A; Bayford R
    Physiol Meas; 2009 Jun; 30(6):S73-84. PubMed ID: 19491443
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The impedance cardiogram recorded through two electrocardiogram/defibrillator pads as a determinant of cardiac arrest during experimental studies.
    Cromie NA; Allen JD; Turner C; Anderson JM; Adgey AA
    Crit Care Med; 2008 May; 36(5):1578-84. PubMed ID: 18434896
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Measurement errors in multifrequency bioelectrical impedance analyzers with and without impedance electrode mismatch.
    Bogónez-Franco P; Nescolarde L; Bragós R; Rosell-Ferrer J; Yandiola I
    Physiol Meas; 2009 Jul; 30(7):573-87. PubMed ID: 19491458
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Impedance of cochlear implant electrode array in scalae tympani].
    Du Q; Wang ZM
    Zhonghua Yi Xue Za Zhi; 2008 Dec; 88(46):3302-4. PubMed ID: 19159560
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Transthoracic defibrillation: importance of avoiding electrode placement directly on the female breast.
    Pagan-Carlo LA; Spencer KT; Robertson CE; Dengler A; Birkett C; Kerber RE
    J Am Coll Cardiol; 1996 Feb; 27(2):449-52. PubMed ID: 8557919
    [TBL] [Abstract][Full Text] [Related]  

  • 16. External defibrillation in the left lateral position--a comparison of manual paddles with self-adhesive pads.
    Dodd TE; Deakin CD; Petley GW; Clewlow F
    Resuscitation; 2004 Dec; 63(3):283-6. PubMed ID: 15582763
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Factors limiting the application of electrical impedance tomography for identification of regional conductivity changes using scalp electrodes during epileptic seizures in humans.
    Fabrizi L; Sparkes M; Horesh L; Perez-Juste Abascal JF; McEwan A; Bayford RH; Elwes R; Binnie CD; Holder DS
    Physiol Meas; 2006 May; 27(5):S163-74. PubMed ID: 16636408
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Electrode position and size in electrical impedance myography.
    Rutkove SB; Partida RA; Esper GJ; Aaron R; Shiffman CA
    Clin Neurophysiol; 2005 Feb; 116(2):290-9. PubMed ID: 15661107
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Characterization of micromachined spiked biopotential electrodes.
    Griss P; Tolvanen-Laakso HK; Meriläinen P; Stemme G
    IEEE Trans Biomed Eng; 2002 Jun; 49(6):597-604. PubMed ID: 12046705
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Cardiac effects of electrical stun guns: does position of barbs contact make a difference?
    Lakkireddy D; Wallick D; Verma A; Ryschon K; Kowalewski W; Wazni O; Butany J; Martin D; Tchou PJ
    Pacing Clin Electrophysiol; 2008 Apr; 31(4):398-408. PubMed ID: 18373757
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.