These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

117 related articles for article (PubMed ID: 10926896)

  • 1. Evaluation of novel assays in clinical chemistry: quantification of plasma total homocysteine.
    Nexo E; Engbaek F; Ueland PM; Westby C; O'Gorman P; Johnston C; Kase BF; Guttormsen AB; Alfheim I; McPartlin J; Smith D; Møller J; Rasmussen K; Clarke R; Scott JM; Refsum H
    Clin Chem; 2000 Aug; 46(8 Pt 1):1150-6. PubMed ID: 10926896
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparison of three different plasma homocysteine assays with gas chromatography-mass spectrometry.
    Ubbink JB; Delport R; Riezler R; Vermaak WJ
    Clin Chem; 1999 May; 45(5):670-5. PubMed ID: 10222354
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Interlaboratory variation of plasma total homocysteine measurements: results of three successive homocysteine proficiency testing surveys.
    Hanson NQ; Eckfeldt JH; Schwichtenberg K; Aras O; Tsai MY
    Clin Chem; 2002 Sep; 48(9):1539-45. PubMed ID: 12194931
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Analytical performance and method comparison study of the total homocysteine fluorescence polarization immunoassay (FPIA) on the AxSYM analyzer.
    Lonati S; Novembrino C; Ippolito S; Accinni R; Galli C; Troonen H; Campolo J; Della Noce C; Lunghi G; Catena FB
    Clin Chem Lab Med; 2004 Feb; 42(2):228-34. PubMed ID: 15061366
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of plasma total homocysteine measurements in 14 laboratories: an international study.
    Pfeiffer CM; Huff DL; Smith SJ; Miller DT; Gunter EW
    Clin Chem; 1999 Aug; 45(8 Pt 1):1261-8. PubMed ID: 10430793
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Comparison of plasma total homocysteine determinations in 9 French hospital laboratories by using 6 different methods].
    Ducros V; Candito M; Caussé E; Couderc R; Demuth K; Diop ME; Drai J; Gerhardt MF; Quillard M; Read MH; Sauvant MP
    Ann Biol Clin (Paris); 2002; 60(4):421-8. PubMed ID: 12147446
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of three methods for total homocysteine plasma determination.
    Brunelli T; Pepe G; Marcucci R; Giusti B; Prisco D; Abbate R; Fedi S
    Clin Lab; 2001; 47(7-8):393-7. PubMed ID: 11499802
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Multicenter study of homocysteine measurement--performance characteristics of different methods, influence of standards on interlaboratory agreement of results.
    Tripodi A; Chantarangkul V; Lombardi R; Lecchi A; Mannucci PM; Cattaneo M
    Thromb Haemost; 2001 Feb; 85(2):291-5. PubMed ID: 11246550
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Performance comparison of three assay methods used in fasting and postmethionine load plasma homocysteine determinations from patients with vascular disease.
    Mourvaki E; Ferrante F; Ghirarduzzi A; Brini M; Depunzio I; Iorio A
    Am J Clin Pathol; 2005 Nov; 124(5):675-81. PubMed ID: 16203288
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Method for the determination of total homocysteine in plasma and urine by stable isotope dilution and electrospray tandem mass spectrometry.
    Magera MJ; Lacey JM; Casetta B; Rinaldo P
    Clin Chem; 1999 Sep; 45(9):1517-22. PubMed ID: 10471655
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Study of homocysteine concentration in coronary heart disease patients and comparison of two determination methods.
    Doncheva N; Penkov A; Velcheva A; Boev M; Popov B; Niagolov Y
    Ann Nutr Metab; 2007; 51(1):82-7. PubMed ID: 17356259
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Clinical validation of a new blood collection tube for the accuracy of total homocysteine measurement by different methods.
    Bissé E; Epting T; Kögel G; Obeid R; Gempel K; Huzly D; Fuhrmann K; Rolinski B; Herrmann W; Wieland H
    Clin Biochem; 2007 Jun; 40(9-10):739-43. PubMed ID: 17467680
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Measurement of total homocysteine in plasma and blood spots using liquid chromatography-tandem mass spectrometry: comparison with the plasma Abbott IMx method.
    McCann SJ; Gillingwater S; Keevil BG; Cooper DP; Morris MR
    Ann Clin Biochem; 2003 Mar; 40(Pt 2):161-5. PubMed ID: 12662404
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparison of the automated AxSYM and ADVIA centaur immunoassays for homocysteine determination.
    Haltmayer M; Mueller T; Gegenhuber A; Poelz W
    Clin Lab; 2004; 50(3-4):175-80. PubMed ID: 15074472
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Evaluation of the Abbott IMx fluorescence polarization immunoassay and the bio-rad enzyme immunoassay for homocysteine: comparison with high-performance liquid chromatography.
    Donnelly JG; Pronovost C
    Ann Clin Biochem; 2000 Mar; 37 ( Pt 2)():194-8. PubMed ID: 10735363
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Determination of total homocysteine in plasma: comparison of the Abbott IMx immunoassay with high performance liquid chromatography.
    Zighetti ML; Chantarangkul V; Tripodi A; Mannucci PM; Cattaneo M
    Haematologica; 2002 Jan; 87(1):89-94. PubMed ID: 11801469
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparison of serum digoxin concentration monitoring by fluorescence polarization immunoassay on the TDxFLx and dry chemistry enzyme immunoassay on the Vitros 950.
    Solnica B
    Clin Chem Lab Med; 2004; 42(8):958-64. PubMed ID: 15387450
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparison of the Abbott IMx and a high-performance liquid chromatography method for measuring total plasma homocysteine.
    Blanco-Vaca F; Arcelús R; González-Sastre F; Ordóñez-Llanos J; Queraltó-Compañó JM
    Clin Chem Lab Med; 2000 Apr; 38(4):327-9. PubMed ID: 10928653
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Agreement among four homocysteine assays and results in patients with coronary atherosclerosis and controls.
    Yu HH; Joubran R; Asmi M; Law T; Spencer A; Jouma M; Rifai N
    Clin Chem; 2000 Feb; 46(2):258-64. PubMed ID: 10657383
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Evaluation of Advia Centaur automated chemiluminescence immunoassay for determining total homocysteine in plasma.
    Demuth K; Ducros V; Michelsohn S; Paul JL
    Clin Chim Acta; 2004 Nov; 349(1-2):113-20. PubMed ID: 15469863
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.