129 related articles for article (PubMed ID: 1092970)
1. A fully automated cardiac output analysis system.
Cohn JD; Marko AR
Med Instrum; 1975; 9(2):93-8. PubMed ID: 1092970
[TBL] [Abstract][Full Text] [Related]
2. An algorithm for the automated determination of cardiac output by the Stewart-Hamilton method.
Francis DB; Hu KC
IEEE Trans Biomed Eng; 1977 Sep; 24(5):482-4. PubMed ID: 330388
[No Abstract] [Full Text] [Related]
3. Thermodilution measurement of cardiac output. A study in dogs comparing direct FICK with an automated thermodilution method (Fischer Cardiac Output Computer).
Arfors KE; Malmberg P
Acta Chir Scand; 1972; 138(8):761-4. PubMed ID: 4565720
[No Abstract] [Full Text] [Related]
4. Simultaneous determinations of cardiac output by thermal dilution, fiberoptic and dye-dilution methods.
Singh R; Ranieri AJ; Vest HR; Bowers DL; Dammann JF
Am J Cardiol; 1970 May; 25(5):579-87. PubMed ID: 4909695
[No Abstract] [Full Text] [Related]
5. On-line cardiac output from dye dilution curves.
Huber F; Sodal IE; Weil JV
Biomed Sci Instrum; 1975; 11():71-3. PubMed ID: 1092375
[No Abstract] [Full Text] [Related]
6. An investigation into the use of the dynamic method of calibration of cardiac output.
King NW; Broughton G
Br J Anaesth; 1967 Jun; 39(6):515-6. PubMed ID: 5338944
[No Abstract] [Full Text] [Related]
7. [Thermodilution procedure for cardiac output determination using an automatic method].
Röder F
Acta Biol Med Ger; 1974; 32(6):665-73. PubMed ID: 4278953
[No Abstract] [Full Text] [Related]
8. Measurement of cardiac output without right heart catheterization: reliability, advantages, and limitations of a left-sided indicator dilution technique.
van den Berg E; Pacifico A; Lange RA; Wheelan KR; Winniford MD; Hillis LD
Cathet Cardiovasc Diagn; 1986; 12(3):205-8. PubMed ID: 3524851
[TBL] [Abstract][Full Text] [Related]
9. Definition of mixing rate of indicator by indicator dilution method: evaluation of relationship between mixing rate of indicator and cardiac output determination.
Taniguchi K; Kirigaya H; Itoh H; Takamoto T; Iesaka Y; Takeuchi J
Bull Tokyo Med Dent Univ; 1986 Jun; 33(2):41-8. PubMed ID: 3552278
[TBL] [Abstract][Full Text] [Related]
10. Automated procedures for indicator-dilution curves using a digital computer.
Anand DK; De Pian L
Biomed Instrum; 1964 Dec; 1(3):21-4. PubMed ID: 5878104
[No Abstract] [Full Text] [Related]
11. [Indicator methods in circulatory diagnosis. A comparison among dye dilution, thermodilution and radiodensitometry].
Rutishauser W
Schweiz Med Wochenschr; 1967 Mar; 97(11):340-7. PubMed ID: 4875572
[No Abstract] [Full Text] [Related]
12. [Methods of cardiac output determination during extracorporeal detoxication].
Nikiforov IuV; Kislukhin VV
Anesteziol Reanimatol; 2003; (2):57-9. PubMed ID: 12939947
[TBL] [Abstract][Full Text] [Related]
13. [Hemodynamic monitoring with the lithium dilution cardiac output system].
Christiansen C; Hostrup A; Tønnesen E; Krogh EH
Ugeskr Laeger; 2008 Feb; 170(7):522-4. PubMed ID: 18291079
[TBL] [Abstract][Full Text] [Related]
14. A comparison between transpulmonary, right and left indicator dilution curves during hypotension.
Blackburn JP; Leigh JM
Br J Anaesth; 1970 Jan; 42(1):90. PubMed ID: 4906518
[No Abstract] [Full Text] [Related]
15. Dilution methods for measurement of cardiac output: A review. SAM-TR-70-5.
Farhi LE
Tech Rep SAM-TR; 1970 Jan; ():143-50. PubMed ID: 4912342
[No Abstract] [Full Text] [Related]
16. Computerized monitoring of cardiac output by thermal dilution.
Ellis RJ; Gold J; Rees JR; Lillehei CW
J Assoc Adv Med Instrum; 1971; 6(2):116-21. PubMed ID: 4947183
[No Abstract] [Full Text] [Related]
17. Analogue-computer corrections for removal of sampling distortion in catheter-densitometer and thermistor systems.
Stage AF; Banchero N
Med Biol Eng; 1973 Mar; 11(2):206-11. PubMed ID: 4572644
[No Abstract] [Full Text] [Related]
18. [Computer evaluation of cardiac output by the indicator dilution method].
Mazurkevich GS; Beliaevskiĭ OA; Dorokhin VM; Senchuk VS; Tiukavin AI
Fiziol Zh SSSR Im I M Sechenova; 1984 Nov; 70(11):1577-81. PubMed ID: 6394365
[No Abstract] [Full Text] [Related]
19. Quantitation of indicator dilution curves by special-purpose analog computers.
Wessel HU; James GW; Paul MH
Med Res Eng; 1966; 5(3):16-21. PubMed ID: 5330276
[No Abstract] [Full Text] [Related]
20. Rapid assessment of cardiac output and central blood volumes from indicator dilution curves without precalculation using programmable calculators.
Cole MA; Crawford DW
Comput Programs Biomed; 1980 Apr; 11(2):105-12. PubMed ID: 6993093
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]