These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

98 related articles for article (PubMed ID: 10930784)

  • 1. Tissue pH in human kidney transplants during hypothermic ischemia.
    Möller HE; Gaupp A; Dietl K; Buchholz B; Vestring T
    Magn Reson Imaging; 2000 Jul; 18(6):743-51. PubMed ID: 10930784
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Pre-transplantation assessment of renal viability with 31P magnetic resonance spectroscopy.
    Hené RJ; van der Grond J; Boer WH; Mali WP; Koomans HA
    Kidney Int; 1994 Dec; 46(6):1694-9. PubMed ID: 7700029
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Kinetics of PME/Pi in pig kidneys during cold ischemia.
    von Elverfeldt D; Niekisch M; Quaschning T; El Saman A; Kirste G; Krämer-Guth A; Hennig J
    NMR Biomed; 2007 Nov; 20(7):652-7. PubMed ID: 17278087
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Kinetics of metabolism in human kidney transplants measured by dynamic 31P NMR spectroscopy.
    Möller HE; Gaupp A; Vestring T; Dietl KH; Vermathen P; Buchholz B; Peters PE
    Z Naturforsch C J Biosci; 1995; 50(5-6):439-50. PubMed ID: 7546037
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Extracellular HTK perfusion and intracellular acidification in ischemic dog kidneys: a 31P NMR spectroscopic study.
    Dittert DD; Siebert AG; Kallerhoff M; Ringert RH
    J Urol; 1997 Mar; 157(3):1064-9. PubMed ID: 9072544
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Pre-transplantation
    Carlbom L; Weis J; Johansson L; Korsgren O; Ahlström H
    Magn Reson Imaging; 2017 Jun; 39():98-102. PubMed ID: 28188872
    [TBL] [Abstract][Full Text] [Related]  

  • 7. In vivo 31P MR spectroscopy of human kidney grafts using the 2D-chemical shift imaging method.
    Vyhnanovská P; Dezortová M; Herynek V; Táborský P; Viklický O; Hájek M
    Transplant Proc; 2011 Jun; 43(5):1570-5. PubMed ID: 21693236
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Assessment of in situ renal transplant viability by 31P-MRS: experimental study in canines.
    Bretan PN; Vigneron DB; Hricak H; Price DC; Yen TS; Luo JA; Tanagho EA; James TL
    Am Surg; 1993 Mar; 59(3):182-7. PubMed ID: 8386489
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Renal 31-phosphorus-magnetic resonance spectral changes in experimental uremia.
    Reichel H; Humburger F; Juretschke HP; Ritz E
    Nephron; 1996; 73(1):27-33. PubMed ID: 8742953
    [TBL] [Abstract][Full Text] [Related]  

  • 10. 31P-nuclear magnetic resonance spectroscopy in vivo of six human melanoma xenograft lines: tumour bioenergetic status and blood supply.
    Lyng H; Olsen DR; Southon TE; Rofstad EK
    Br J Cancer; 1993 Dec; 68(6):1061-70. PubMed ID: 8260356
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Pretransplant assessment of renal viability by phosphorus-31 magnetic resonance spectroscopy. Clinical experience in 40 recipient patients.
    Bretan PN; Baldwin N; Novick AC; Majors A; Easley K; Ng T; Stowe N; Rehm P; Streem SB; Steinmuller DR
    Transplantation; 1989 Jul; 48(1):48-53. PubMed ID: 2665235
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Assessment of renal viability by phosphorus-31 magnetic resonance spectroscopy.
    Bretan PN; Vigneron DB; James TL; Williams RD; Hricak H; Juenemann KP; Yen TS; Tanagho EA
    J Urol; 1986 Apr; 135(4):866-71. PubMed ID: 3514965
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Adult-size kidneys without acute tubular necrosis provide exceedingly superior long-term graft outcomes for infants and small children: a single center and UNOS analysis. United Network for Organ Sharing.
    Sarwal MM; Cecka JM; Millan MT; Salvatierra O
    Transplantation; 2000 Dec; 70(12):1728-36. PubMed ID: 11152105
    [TBL] [Abstract][Full Text] [Related]  

  • 14. One-dimensional phosphorus-31 chemical shift imaging of human brain tumors.
    Rutter A; Hugenholtz H; Saunders JK; Smith IC
    Invest Radiol; 1995 Jun; 30(6):359-66. PubMed ID: 7490188
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Phosphorus-31 nuclear magnetic resonance of isolated rat liver during hypothermic ischemia and subsequent normothermic perfusion.
    Delmas-Beauvieux MC; Gallis JL; Rousse N; Clerc M; Canioni P
    J Hepatol; 1992 May; 15(1-2):192-201. PubMed ID: 1506639
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Phosphorus-31 MRS of the kidney.
    Hricak H
    Invest Radiol; 1989 Dec; 24(12):993-6. PubMed ID: 2691445
    [TBL] [Abstract][Full Text] [Related]  

  • 17. 31P-magnetic resonance spectroscopy (31P-MRS) of human allografts after renal transplantation.
    Klemm A; Rzanny R; Fünfstück R; Werner W; Schubert J; Kaiser WA; Stein G
    Nephrol Dial Transplant; 1998 Dec; 13(12):3147-52. PubMed ID: 9870480
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Improved pretransplant assessment of renal quality by means of phosphorus-31 magnetic resonance spectroscopy using chemical shift imaging.
    Niekisch MB; Von Elverfeldt D; El Saman A; Hennig J; Kirste G
    Transplantation; 2004 Apr; 77(7):1041-5. PubMed ID: 15087769
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Potential of 31P magnetic resonance spectroscopy in monitoring the viability of human renal grafts stored in Euro-Collins perfusion solution.
    Kurková D; Herynek V; Gintelová J; Táborský P; Hájek M
    Physiol Res; 1995; 44(5):327-32. PubMed ID: 8869268
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Hepatic nucleotide triphosphate regeneration after hypothermic reperfusion in the pig model: an in vitro P-NMR study.
    Changani KK; Fuller BJ; Bell JD; Bryant DJ; Moore DP; Taylor-Robinson SD; Davidson BR
    Transplantation; 1996 Sep; 62(6):787-93. PubMed ID: 8824479
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.