116 related articles for article (PubMed ID: 10933097)
1. Evaluation of a portable respiratory recording device for detecting apnoeas and hypopnoeas in subjects from a general population. Ballester E; Solans M; Vila X; Hernandez L; Quintó L; Bolivar I; Bardagi S; Montserrat JM Eur Respir J; 2000 Jul; 16(1):123-7. PubMed ID: 10933097 [TBL] [Abstract][Full Text] [Related]
2. Comparison of ResMed AutoSet (version 3.03) with polysomnography in the diagnosis of the sleep apnoea/hypopnoea syndrome. Gugger M Eur Respir J; 1997 Mar; 10(3):587-91. PubMed ID: 9072989 [TBL] [Abstract][Full Text] [Related]
3. Comparison of partially attended night time respiratory recordings and full polysomnography in patients with suspected sleep apnoea/hypopnoea syndrome. Lloberes P; Montserrat JM; Ascaso A; Parra O; Granados A; Alonso P; Vilaseca I; Rodriguez-Roisin R Thorax; 1996 Oct; 51(10):1043-7. PubMed ID: 8977607 [TBL] [Abstract][Full Text] [Related]
4. Diagnostic accuracy of a portable recording device (MESAM IV) in suspected obstructive sleep apnoea. Esnaola S; Durán J; Infante-Rivard C; Rubio R; Fernández A Eur Respir J; 1996 Dec; 9(12):2597-605. PubMed ID: 8980975 [TBL] [Abstract][Full Text] [Related]
5. An unattended device for sleep-related breathing disorders: validation study in suspected obstructive sleep apnoea syndrome. Zucconi M; Ferini-Strambi L; Castronovo V; Oldani A; Smirne S Eur Respir J; 1996 Jun; 9(6):1251-6. PubMed ID: 8804946 [TBL] [Abstract][Full Text] [Related]
6. Visual and different automatic scoring profiles of respiratory variables in the diagnosis of sleep apnoea-hypopnoea syndrome. Carrasco O; Montserrat JM; Lloberes P; Ascasco C; Ballester E; Fornas C; Rodriguez-Roisin R Eur Respir J; 1996 Jan; 9(1):125-30. PubMed ID: 8834345 [TBL] [Abstract][Full Text] [Related]
7. [Utility of portable monitoring device with airflow, oxygen saturation and respiratory effort in the diagnosis of sleep apnea hypopnea syndrome]. Yan H; Dong XS; Li YQ; Liu YN; Li J; An P; Zhao L; Gao ZC; Han F Zhonghua Yi Xue Za Zhi; 2013 Feb; 93(6):415-8. PubMed ID: 23660258 [TBL] [Abstract][Full Text] [Related]
8. Utility of new-generation pacemakers in sleep apnea screening. Dias M; Gonçalves I; Amann B; Marques P; Martinho C; Leitão C; Basto RP; de Sousa J; Pinto P; Bárbara C Sleep Med; 2017 Sep; 37():27-31. PubMed ID: 28899536 [TBL] [Abstract][Full Text] [Related]
9. The minimum period of polysomnography required to confirm a diagnosis of severe obstructive sleep apnoea. Chou KT; Chang YT; Chen YM; Su KC; Perng DW; Chang SC; Shiao GM Respirology; 2011 Oct; 16(7):1096-102. PubMed ID: 21762445 [TBL] [Abstract][Full Text] [Related]
10. Digital monitoring of sleep-disordered breathing using snoring sound and arterial oxygen saturation. Issa FG; Morrison D; Hadjuk E; Iyer A; Feroah T; Remmers JE Am Rev Respir Dis; 1993 Oct; 148(4 Pt 1):1023-9. PubMed ID: 8214920 [TBL] [Abstract][Full Text] [Related]
11. [The validation of a portable 3-channel recording system (Oxyflow, Edentec) for the diagnosis of the sleep apnea syndrome]. Jiménez Gómez A; Golpe Gómez R; Carpizo Alfayate R; de la Roza Fernández C; Fernández Rozas S; García Pérez MM Arch Bronconeumol; 2000 Jan; 36(1):7-12. PubMed ID: 10726178 [TBL] [Abstract][Full Text] [Related]
12. Detection of apnoeas, hypopnoeas and arousals by the AutoSet in the sleep apnoea/hypopnoea syndrome. Rees K; Wraith PK; Berthon-Jones M; Douglas NJ Eur Respir J; 1998 Oct; 12(4):764-9. PubMed ID: 9817142 [TBL] [Abstract][Full Text] [Related]
13. Comparison of a cardiorespiratory device versus polysomnography for diagnosis of sleep apnoea. Calleja JM; Esnaola S; Rubio R; Durán J Eur Respir J; 2002 Dec; 20(6):1505-10. PubMed ID: 12503711 [TBL] [Abstract][Full Text] [Related]
14. Should patients with sleep apnoea/hypopnoea syndrome be diagnosed and managed on the basis of home sleep studies? Parra O; García-Esclasans N; Montserrat JM; García Eroles L; Ruíz J; López JA; Guerra JM; Sopeña JJ Eur Respir J; 1997 Aug; 10(8):1720-4. PubMed ID: 9272909 [TBL] [Abstract][Full Text] [Related]
15. [Diagnostic value of portable monitor device in patients with potential obstructive sleep apnea hypopnea syndrome]. Liang S; Chen Z; Huang J; Zhao X; Huang Y; Zhang R Zhonghua Er Bi Yan Hou Tou Jing Wai Ke Za Zhi; 2016 Mar; 51(3):209-11. PubMed ID: 27033576 [TBL] [Abstract][Full Text] [Related]
16. Validation a portable monitoring device for sleep apnea diagnosis in a population based cohort using synchronized home polysomnography. Zou D; Grote L; Peker Y; Lindblad U; Hedner J Sleep; 2006 Mar; 29(3):367-74. PubMed ID: 16553023 [TBL] [Abstract][Full Text] [Related]
17. Obstructive sleep apnoea syndrome: comparison between polysomnography and portable sleep monitoring based on jaw recordings. Cheliout-Heraut F; Senny F; Djouadi F; Ouayoun M; Bour F Neurophysiol Clin; 2011 Oct; 41(4):191-8. PubMed ID: 22078731 [TBL] [Abstract][Full Text] [Related]
18. Validation of a portable recording device (ApneaLink) for identifying patients with suspected obstructive sleep apnoea syndrome. Ng SS; Chan TO; To KW; Ngai J; Tung A; Ko FW; Hui DS Intern Med J; 2009 Nov; 39(11):757-62. PubMed ID: 19220528 [TBL] [Abstract][Full Text] [Related]
19. Usefulness of ambulatory ECG in the diagnosis of sleep-related breathing disorders. Ozegowski S; Wilczyńska E; Piorunek T; Szymanowska K; Paluszkiewicz L Kardiol Pol; 2007 Nov; 65(11):1321-8; discussion 1329-30. PubMed ID: 18058583 [TBL] [Abstract][Full Text] [Related]